3051smv transition
Sponsored Links
This presentation is the property of its rightful owner.
1 / 13

3051SMV Transition PowerPoint PPT Presentation


  • 159 Views
  • Uploaded on
  • Presentation posted in: General

3051SMV Transition. Agenda. Transition to the 3051SMV: 3095M-HART Discontinuance 3095M-HART Final Order Date Models Affected 3051SMV Feature Improvements 3095M-HART Comparison Flowmeter Offering Engineering Assistant Support Summary. Transition to the 3051SMV from the 3095M-HART.

Download Presentation

3051SMV Transition

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


3051SMV Transition


Agenda

  • Transition to the 3051SMV: 3095M-HART Discontinuance

    • 3095M-HART Final Order Date

    • Models Affected

  • 3051SMV Feature Improvements

    • 3095M-HART Comparison

    • Flowmeter Offering

    • Engineering Assistant Support

  • Summary


Transition to the 3051SMV from the 3095M-HART

  • Since the release of the 3051SMV in Oct. 2009, market led transition was expected

    • 3051SMV has higher performance and more features

  • Transition time-frame shortened by Japanese crisis

    • Earthquake and resulting tsunami destroyed a supplier’s factory

    • Supplier has decided to discontinue the component

    • Timeframe to redesign unacceptable

    • No other 3095 or Rosemount products are affected

40% of customers already transitioned


3095M-HART Final Order Date

  • Final Order Date:

    July 29, 2011

  • Orders will ship at standard lead-times

  • Service and warranty requests will be honored with remaining 3095M-HART inventory or an upgrade to 3051SMV

    • Option to upgrade at the cost to repair a 3095M through for two years or five years from the original shipment date of device, whichever comes first


3095M-HART Models To Be Transitioned

  • 3095MA HART Transmitters

    • 3095MAxxxxxxxxxxxxx…

    • NOT Affected:

      • 3095MV FOUNDATION fieldbus

      • 3095FB MODBUS

  • 3095MFx HART Flowmeters

    • 3095MFAxxxxxxxxxxxxxxxxxAxx...

    • 3095MFCxxxxxxxxxxxxxAxx…

    • 3095MFPxxxxxxxxxxxxxxxAxx…

    • NOTAffected:

      • 3095MFx FOUNDATION fieldbus Flowmeters

3095MA HART

3095MFC

3095MFP

3095MFA


Rosemount 3051S MultiVariable HART Transmitter

Joule Thomson Correction

Energy and Mass or Actual Volumetric Flow

Sensor Matching with Callendar-van Dusen

Easy 2 Step

Configuration

Ultra For Flow

Real-time compensation of over 25 variables @ 22 updates/second

User specified temperature limits and temperature backup

% Reading

Scalable

Compensation

Terminal block temperature wiring

10

±0.1% Span

9

3051C

8

3051S Ultra

7

Ultra for Flow

6

Flow Turndown

5

4

3

2

1

0

10:1

5:1

3:1

2:1

1:1


Integrated Flowmeters Available With the 3051SMV

3051SFx Flowmeters Offer Equivalent 3095MFx Features

  • Fully Assembled, Configure, Leak Tested

  • Annubar, Compact Orifice, and Integral Orifice

  • Integral Temperature option

3051SFP

3051SFC

3051SFA


Transitioning to the Rosemount 3051SMV Improves Flow Measurement

  • 3051SMV: Superior Flow Measurement

  • Improved Mass and Energy Flow Calculations

  • Scalable Measurement Options for Liquids and Saturated Steam

  • Easy Start-up and Simplified Maintenance with Engineering Assistant 6.1.1


3051SMV vs. 3095M-HARTPhysical Comparison

3051SMV

  • Coplanar

    Connection

  • Height: 8.53-in.

    (217 mm)

    • 1.46-in. (37 mm) taller

  • Weight: 6.7 lbs (3.0 kg)

    • 0.7lb (0.3 kg) heavier

  • Temperature Connection

    • Terminal Block

3095M-HART

  • Coplanar

  • Connection

  • Height: 7.07-in.

  • (180 mm)

  • Weight: 6.0 lbs (2.7 kg)

  • Temperature Connection

    • Temperature Boss


3051SMV vs. 3095M-HARTDimensional Comparison

3051SMV

3095M-HART


Engineering Assistant Support

EA 6.1.1

  • For 3051SMV

  • Stand alone

  • AMS SNAP-ON planned

  • Full listing of fluids

  • Most primaries supported

  • Ongoing maintenance releases for new capabilities

  • EA 5.5.1

  • For 3095M

  • Stand alone

  • powered by AMS

  • AMS SNAP-ON

  • Full listing of primary elements and fluids

  • Available to support legacy installations

Both versions will continue to be available


Start Your Transition to the 3051SMV Transmitter and Flowmeters Today

  • REMEMBER: Last Order Date for 3095M-HART

    • July 29, 2011

  • 3051SMV Offers Equivalent 3095M-HART Features and More:

    • Superior Flow Measurement Performance

    • Improved Temperature Measurement

    • Fully Integrated Flowmeters

3051SFP

3051SFC

3051SFA


  • Login