3051SMV Transition. Agenda. Transition to the 3051SMV: 3095M-HART Discontinuance 3095M-HART Final Order Date Models Affected 3051SMV Feature Improvements 3095M-HART Comparison Flowmeter Offering Engineering Assistant Support Summary. Transition to the 3051SMV from the 3095M-HART.

Download Presentation

3051SMV Transition

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


3051smv transition

3051SMV Transition


Agenda

Agenda

  • Transition to the 3051SMV: 3095M-HART Discontinuance

    • 3095M-HART Final Order Date

    • Models Affected

  • 3051SMV Feature Improvements

    • 3095M-HART Comparison

    • Flowmeter Offering

    • Engineering Assistant Support

  • Summary


Transition to the 3051smv from the 3095m hart

Transition to the 3051SMV from the 3095M-HART

  • Since the release of the 3051SMV in Oct. 2009, market led transition was expected

    • 3051SMV has higher performance and more features

  • Transition time-frame shortened by Japanese crisis

    • Earthquake and resulting tsunami destroyed a supplier’s factory

    • Supplier has decided to discontinue the component

    • Timeframe to redesign unacceptable

    • No other 3095 or Rosemount products are affected

40% of customers already transitioned


3095m hart final order date

3095M-HART Final Order Date

  • Final Order Date:

    July 29, 2011

  • Orders will ship at standard lead-times

  • Service and warranty requests will be honored with remaining 3095M-HART inventory or an upgrade to 3051SMV

    • Option to upgrade at the cost to repair a 3095M through for two years or five years from the original shipment date of device, whichever comes first


3095m hart models to be transitioned

3095M-HART Models To Be Transitioned

  • 3095MA HART Transmitters

    • 3095MAxxxxxxxxxxxxx…

    • NOT Affected:

      • 3095MV FOUNDATION fieldbus

      • 3095FB MODBUS

  • 3095MFx HART Flowmeters

    • 3095MFAxxxxxxxxxxxxxxxxxAxx...

    • 3095MFCxxxxxxxxxxxxxAxx…

    • 3095MFPxxxxxxxxxxxxxxxAxx…

    • NOTAffected:

      • 3095MFx FOUNDATION fieldbus Flowmeters

3095MA HART

3095MFC

3095MFP

3095MFA


3051smv transition

Rosemount 3051S MultiVariable HART Transmitter

Joule Thomson Correction

Energy and Mass or Actual Volumetric Flow

Sensor Matching with Callendar-van Dusen

Easy 2 Step

Configuration

Ultra For Flow

Real-time compensation of over 25 variables @ 22 updates/second

User specified temperature limits and temperature backup

% Reading

Scalable

Compensation

Terminal block temperature wiring

10

±0.1% Span

9

3051C

8

3051S Ultra

7

Ultra for Flow

6

Flow Turndown

5

4

3

2

1

0

10:1

5:1

3:1

2:1

1:1


Integrated flowmeters available with the 3051smv

Integrated Flowmeters Available With the 3051SMV

3051SFx Flowmeters Offer Equivalent 3095MFx Features

  • Fully Assembled, Configure, Leak Tested

  • Annubar, Compact Orifice, and Integral Orifice

  • Integral Temperature option

3051SFP

3051SFC

3051SFA


Transitioning to the rosemount 3051smv improves flow measurement

Transitioning to the Rosemount 3051SMV Improves Flow Measurement

  • 3051SMV: Superior Flow Measurement

  • Improved Mass and Energy Flow Calculations

  • Scalable Measurement Options for Liquids and Saturated Steam

  • Easy Start-up and Simplified Maintenance with Engineering Assistant 6.1.1


3051smv vs 3095m hart physical comparison

3051SMV vs. 3095M-HARTPhysical Comparison

3051SMV

  • Coplanar

    Connection

  • Height: 8.53-in.

    (217 mm)

    • 1.46-in. (37 mm) taller

  • Weight: 6.7 lbs (3.0 kg)

    • 0.7lb (0.3 kg) heavier

  • Temperature Connection

    • Terminal Block

3095M-HART

  • Coplanar

  • Connection

  • Height: 7.07-in.

  • (180 mm)

  • Weight: 6.0 lbs (2.7 kg)

  • Temperature Connection

    • Temperature Boss


3051smv vs 3095m hart dimensional comparison

3051SMV vs. 3095M-HARTDimensional Comparison

3051SMV

3095M-HART


Engineering assistant support

Engineering Assistant Support

EA 6.1.1

  • For 3051SMV

  • Stand alone

  • AMS SNAP-ON planned

  • Full listing of fluids

  • Most primaries supported

  • Ongoing maintenance releases for new capabilities

  • EA 5.5.1

  • For 3095M

  • Stand alone

  • powered by AMS

  • AMS SNAP-ON

  • Full listing of primary elements and fluids

  • Available to support legacy installations

Both versions will continue to be available


Start your transition to the 3051smv transmitter and flowmeters today

Start Your Transition to the 3051SMV Transmitter and Flowmeters Today

  • REMEMBER: Last Order Date for 3095M-HART

    • July 29, 2011

  • 3051SMV Offers Equivalent 3095M-HART Features and More:

    • Superior Flow Measurement Performance

    • Improved Temperature Measurement

    • Fully Integrated Flowmeters

3051SFP

3051SFC

3051SFA


  • Login