1 / 35

Introduction Nanoclusters of Fm atoms have high proportion of surface atoms

IAEA CRP: Ion Beam Modification of Insulators RCM, Dec. 10-14, 2007, FNRC, Uni. Chiang Mai, Thailand. Study of the formation of ferro-, para- and superpara-magnetic nano clusters by ion implantation itno suitable insulators

zea
Download Presentation

Introduction Nanoclusters of Fm atoms have high proportion of surface atoms

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IAEA CRP: Ion Beam Modification of InsulatorsRCM, Dec. 10-14, 2007, FNRC, Uni. Chiang Mai, Thailand Study of the formation of ferro-, para- and superpara-magnetic nano clusters by ion implantation itno suitable insulators Principal investigators : Prof. K. Bharuth-Ram , University of KwaZulu-Natal, Durban and iThemba LABS, Faure. S. Africa Prof. Dr. Hans Hofsaess, Universitaet Goettingen, Germany + Carsten Ronning, Peter Schaaf, Michael Uhrmacher, Uni-Goettingen. Terry Doyle, Cebo …, iThemba LABS, South Africa. + Uli Wahl: Emission channeling Gerd Weyer et al., MS following Mn57 implantation

  2. Introduction • Nanoclusters of Fm atoms have high proportion of surface atoms • increase spin magnetic moment towards high spin limit • reduction in effective quenching of the orbital magnetic moment. • + quantum size effects + modified valence electron screening • Novel properties: magnetic moments enhanced by up to 35% superparamagnetic behaviour in clusters below a critical size magnetic behaviour in non-FM transition metals Applications in ultra-high recording magnetic recording media, information and telecommunications technology. Achieved already by ion implantation at doses of 1017 cm-2. - due to accumulation at extended lattice sites? or diffusion and agglomeration of implanted ions?

  3. Objective: • Investigate the implantation parameters required to achieve magnetic • nano-clusters, • i.e. energy and dose, • sample temperature and annealing characteristics, • Methodsinclude • Temperature dependent Moessbauer spectroscopy and magnetization measurements, to determine the size of clusters and their magnetic properties. • RBS and Raman Spectrometry, MOKE, UV-VIS Transmission Spectrometry • -- to determine implantation profile and complex formation in the host matrix.

  4. Reported on in June 2006: Implant of 57Fe at E = 60 keV, at Uni-Goettingen to a dose of 5 x 1015 cm-2 . Substrates: 3C-SiC, CVD diamond, graphite Moessbauer spectroscopy (at UKZN) at RT and LN2 on 3C-SiC sample: as-implanted sample, and after annealing at 400 C. Moessbauer spectroscopy (at Uni-Goettingen) after annealing at 600 C VSM on as-implanted and after annealing at 600 C on 3C-SiC sample MOKE and Raman Spectroscopy on as- implanted and after annealing at 400 C and 600 C: CVD and 3C-SiC samples

  5. Results: Mossbauer Measurements Mossbauer measurements were made with a approx. 8 mCi source (30 mCi in May 2003). Each spectrum at RT, has > 10 million events, accumulated over 4 weeks. At LN2, longer measurement time was required.

  6. MOKE Measurements (Magneto-Optical Kerr Effect) b) TA = 900 K a) As implanted

  7. VSM Measurements • (TB Doyle, UKZN) • SiC(Fe) sample , Virgin SiC, Holder VSM measurements only possible after acquisition of a bipolar power supply for magnet, obtained in 2005 as donation from the Alexander von Humboldt Stiftung. Plot shows average of data collected during many measurements over several months (TB Doyle). We are at the limit of resolution of the device, but a small ferromagnetic effect is noticeable.

  8. Raman Spectroscopy a) CVD diamond as-Implanted b) CVD diamond annealed at 900 K c) 3C-SiC sample annealed at 900K

  9. There is evidence of ferromagnetic and paramagnetic ordering, but data with better statistics is required. So, Plans for 2007 included: i) obtaining new, stronger Moessbauer Sources (50 mCi) ii) Increasing the concentration of Fe in the samples, iii) investigating implantation induced magnetization effects in other substrates. Early in 2007, enriched 57Fe pellets were purchased, and implantation into 3C-SiC, CVD diamond, ZnO, SiO2 and graphite were undertaken at 60 and 80 keV energy, and up to a fluence of 1 x 1016/cm2 (at Goettingen). Two 50mCi MS sources ordered, eventually delivered in Oct. 2007 Measurements from end October : CEMS, TMS.

  10. Hyperfine Interactions and Measurables 1. Isomer Shift 3. Electric Quadrupole Interaction d = k (rabs – rref)(<re2> – <rg2 >), lattice site, charge state Emag = - m . B Emag = mI . g mN. Bz 2. Magnetic interaction SAIP 2007

  11. RBS Measurements 2 MeV 4He+ Grazing angle = -10O

  12. UV-VIS Transmission • 3C-SiC: virgin and implanted region • i) as implanted, • ii) Annealed at 350C. • 2. ZnO: Implanted regions • i) as implanted • ii) Annealed at 350 C.

  13. 3C-SiC 1 x 1016/cm2

  14. SiO2

  15. ZnO TA= 350 C as Impl.

  16. Moessbauer Measurements • CVD Diamond:

  17. Magnetization measurements ??? -- merger of UDW and UN  UKZN - School of Physics (and Fac. of Science) to Westville campus VSM equipment dismantled – and still in boxes!!!

  18. Moessbauer Studies following 57Mn implantation 57Mn 57Co b EC 5/2- 137 keV 1. 57Co source: 30 mCi + Typical dose: 5 x 101457Fe  tm ~ 14 days lattice damage 2. In-beam MS CE and recoil implant 57Fe* tm ~ 24 –36 hrs Dose < 1010 cm-2. teff = t . 3. 57Mn* implantation Dose < 1013 cm-2. b decay  57Fe* Erecoil = 40 keV tm~ 10 min. CE 3/2- 14.4 keV, 98 ns 0 ½- 57Fe At ISOLDE, CERN Mass separated 57Mn* accelerated to 60 keV, and implanted into sample held at temp T. 14.4 (+DE) keV gammas detected in PPAC, mounted directly on to MDU.

  19. Production of radioactive ion beams at ISOLDE, CERN.

  20. 3C-SiC

  21. Graphite

  22. Components: S1 : Single line D1: defect doublet Sx1 : sharp FM sextet Sx2 & Sx3: Broad sextets with Eq interaction. Effect is reversible.  due Fe-V-O complex??

  23. Conclusions 1. The lighter mass substrates ( SiC, SiO2) hold greater promise. 2. After implantation to a fluence of 1 x 1016 / cm2  indications of magnetically split components in Moessbauer spectra  this fluence gives Moessbauer spectra with acceptable statistics  higher dose implantation with Fe-56 other fm species (Mn, Co) non-fm species (Na, C)

  24. ACKNOWLEDGEMENTS • IAEA – Wulf Rosenberg and Francoise Mullhauser • Hans Hofsaess, Uli wahl and colleagues in Goettingen • Yu Liangden and FNRC, Chiang Mai University • The Group generally. • Thank You