1 / 20

ARM - COALTEC

C oal C ombustion R edefined. ARM - COALTEC. WE SAVE LIVES, WE REDUCE COSTS. FUEL ADDITIVE FOR COAL/LIGNITE/PETCOKE. Advanced Resources & Marketing Pvt. Ltd. 91,Empire Building, 2 nd Floor, Dr. D. N. Road, Fort, Mumbai-400 001, India

zaria
Download Presentation

ARM - COALTEC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Coal CombustionRedefined ARM-COALTEC WE SAVE LIVES, WE REDUCE COSTS FUEL ADDITIVE FOR COAL/LIGNITE/PETCOKE Advanced Resources & Marketing Pvt. Ltd. 91,Empire Building, 2nd Floor, Dr. D. N. Road, Fort, Mumbai-400 001, India Tel: +91 22 2207-1851, +91 9821-069654, Email: armpltd@gmail.com www.armpltd.com

  2. CONTENTS C. Implementing the additive • Implementing of additive and Trials • Investments and Operating Costs • Cost Benefit Analysis • Request for Boiler/Furnace Data A. Introduction • Technical Firing Aspects of Boilers/Kiln • Introduction to ARM-Coaltec • Economic and Operational Benefits • Environmental Benefits B. ARM - Coaltec Functions and Utilities • Functions and Utilities • Catalyst • Oxidant • Sulphur-Fixative • De-Ashing and De-Dusting Agent • Loosening Agent • Anti-Corrosive

  3. TECHNICAL FIRING ASPECTS OF BOILER The technical firing of solid fuels depend largely on the speed of combustion, which relies on the fuel layer thickness of the grate, speed of the grate and air flow. Optimal setting of the Boiler/Kiln is achieved when the substrate stops burning and glowing just before the end of the grate. The right setting of air flow is important for achieving acceptable CO and NOX emissions. High excess air leads to high losses of heat and high NOX emission. Low excess air leads to high CO-emission, black smoke and a high carbon content of ash.

  4. WE SAVE LIVES, WE REDUCE COSTS ARM -Coaltec

  5. ECONOMIC AND OPERATIONAL BENEFITS • Increase in Boiler/Kiln Efficiency, resulting in fuel savings • Lesser LOI in ash and slag • Reduction in Operating & Maintenance costs • Increase in energy lifetime of Boiler/Kiln • Cleaner Boiler/Kiln walls with deposits free operation

  6. ENVIRONMENTAL BENEFITS • Reduction of SO2 emission by 50-80% • Reduction of SPM and RSPMemission by up-to 50% • Significant reduction of CO and NOx emissions • Reduction of thermal emission • Reduces CO2 emission, reducing global warming

  7. FUNCTIONS AND UTILITIES • CATALYST • ANTI-CORROSIVE • OXIDANT - COALTEC • LOOSENING AGENT • SUPLHUR FIXATIVE • DE-ASHING & DE-DUSTING

  8. FUNCTIONS AND UTILITIES 1 CATALYST • Enables Quick and High carbon burnout of the solid fuel, providing improved flame stability • Results in Uniform and Synchronized Combustion • Facilitates oxygen diffusion to internal regions of Coal, reducing surplus air requirements • Reduces Auto-Ignition temperature • Expands the range of ignition points by enabling oxygen to mix with other combustible gases

  9. UNIFORM AND SYNCHRONIZED COMBUSTION With additive Without additive • Bomb Calorie Meter Test: • Use of the additive results in uniform and synchronized combustion resulting in higher heat intensity for a longer period. • The peak is achieved earlier and is maintained for a longer duration. The additive increases the rate of heat transfer by altering the heat generation frequency Bomb Calorie Meter Test:

  10. REDUCTION IN SURPLUS AIR, CO, NOx CO, unburned Carbon NOX Emissions Reduction in NOX & CO emission with Arm-Coaltec Normal Level Optimum O2 With Arm-Coaltec O2 Excess

  11. FUNCTIONS AND UTILITIES OXIDANT 2 • Increases combustion efficiency of coal, whereby volatile combustibles, free carbon particles and SPM can be readily combusted. • Enables complete combustion of carbon to CO2, reducing CO and black smoke. • Reduces the unburnts in bottom ash & Fly ash.

  12. BETTER FIRE SHAPE AND FLAME STABILITY Flame without Additive • Regular flame • Long and regular fire bed • Reduced CO and NOx • Reduction in wasted airflow Flame without Additive Flame with Additive • Irregular flame • Irregular fire bed • High air flow

  13. FUNCTIONS AND UTILITIES SULPHUR FIXATIVE 3 • Absorbs SO2 produced in furnace reducing sulphur emissions in the range of 50-80%. • Captures the sulphur particles resulting in reduction in SPM & RSPM. • Deodorizes the Boiler/Kiln and frees the furnace walls from dirt. • Reduces Acid-Smut and Acid-Plume, reducing acid rains.

  14. ACTION ON SULPHUR • S + O2 SO2 • 4FeS2 + 11O2 2Fe2O3 + 8SO2 • 7FeS2 + 6O2 Fe7S8 + 6SO2 • 3Fe7S8 + 38O2 7Fe3O4 + 24SO2 • R- S + n2 nSO2 + nH2O • Sulphur content in Solid Fuel comprises of organic and inorganic sulphur which is present in the form of the R – S and FeS2. The combustible sulphur is released in the form of SO2, an air borne pollutant. • Arm – Coaltec as an additive has seals & catalysts that absorbs and captures the SO2 produced in the furnace. The additive effectively absorbs the SO2 in the first stage ,converts it into a sulphate and retains it within the ash.

  15. FUNCTIONS AND UTILITIES De-Ashing and De-Dusting Agent 4 • Facilitates removal of contaminants from the furnace water wall and heat transfer surfaces by making the dust loose, powdery and porous. • Better efficiency and prevention of heat losses. • It is estimated that an accumulation of 1mm of soot increases fuel consumption by 5%. • Use of additive results in large savings in the long run.

  16. FUNCTIONSAND UTILITIES Enhances coal combustion by cracking the layers of coal and making them fluffy. LOOSENING AGENT 6 ANTI-CORROSIVE AGENT • As Boilers/Kilns are subjected to continued usage, the thickness of the walls may reduce owing to corrosion. Contaminants such as residual dust, ash and smoke which impact the furnace walls, increase with passage of time which in turn reduces efficiency in the long run. • The additive contains a High temperature corrosion inhibitor that protects the furnace wall and apparatus from corrosion and thinning due to attack.

  17. IMPLEMENTING THE ADDITIVE AND TRIALS Before implementing the fuel additive, the Boiler/Kiln parameters will be studied by ARM personnel and its agencies along with the plant. A CDE Customer Data Evaluation (Detailed) will becompiled, as a pre-cursor to the proposal of a suitable solution with its allied benefits. Based on the collected data the methodology for the trial will be determined. The trials can be long term lasting 4 to 6 weeks or a short term run lasting 10 – 12 days depending on the system. From the results of this practical run, the benefits of the additive can be realized and accurate savings will be determined.

  18. INVESTMENTS AND OPERATING COSTS For the application of the Additive, dosing equipment is required, which consists of a vibro-dozer / screw feeder. The type & cost of this dosing equipment depends on the kind of Boiler/Kiln system. ARM Pvt. Ltd. is prepared to submit a specified offer for investment costs if the necessary data of Boiler/Kiln and installation site is known. The operational costs of Fuel Additive dosing is dependent on fuel characteristics and the furnace / burning situation. They can be calculated & ascertained after the aims of the Fuel Additive application are determined . The dosing rate depends on the type of fuel & operating conditions of the Boiler/Kiln. The ratio of dosing is approximately 1 kg : 3MT of solid fuel.

  19. COST BENEFIT ANALYSIS

  20. REQUEST FOR BOILER / KILN DATA C MAKES BUSINESS NOT COMPETE WITH CONSERVATION ! We strongly recommend ARM Coaltec to meet your operational & environmental objectives. Please provide details concerning your actual installation & end use application to enable us to serve you better. Based on this data a detailed offer for dosing of the additive will be provided. Kindly submit your CDE Customer Data Evaluation for the best response. For any assistance contact us at +919821069654 / armpltd@gmail.com.