Air Quality

Air Quality. Aneta Stefanovska Advisor in international and local eco-networks. ETC –ACC visit and regional meeting of West Balkans countries Skopje, 28-29.03.2006. Legislation. Law on Air Protection against Pollution

zada
Download Presentation

Air Quality

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Air Quality Aneta Stefanovska Advisor in international and local eco-networks ETC –ACC visit and regional meeting of West Balkans countries Skopje, 28-29.03.2006

  2. Legislation • Law on Air Protection against Pollution • Law on Ambient Air Quality, harmonized with Framework Directive 96/62/EEC • Secondary legislation • Decree on ambient air quality limit values, margins of tolerance and alert thresholds, transposing Directives 99/30/EC, 2000/69/EC, 2002/3/EC • Rulebook on ambient air quality assessment, transposing Directives 99/30/EC, 2000/69/EC, 2002/3/EC

  3. Legislation • Secondary legislation which should be drafted • Rulebook on preliminary ambient air quality assessment and establishment of ambient air quality zones and agglomerations • Rulebook on air pollution monitoring and reporting • Other regulations based on the Law on Ambient Air Quality.

  4. Institutions performing air quality monitoring in the Republic of Macedonia • Hydrometeorological administration • Public health institutes • Ministry of environment and physical planning

  5. Hydrometeorological administration

  6. Hydrometeorological administration • SO2 and black smoke are measured at 9 measuring points in Skopje and in 10 other cities in the country: Berovo, Bitola, Tetovo, Gevgelija, Kumanovo, Ohrid, Prilep, Stip, Veles and Lazaropole. • NO2 and O3 are measured at 2 measuring points: Karpos IV and Lazaropole (EMEP station)

  7. Public Health Institute - Skopje • SO2 is measured at 4 measuring points • Black smoke is measured at 7 measuring points

  8. Public Health Institute - Skopje • Aero sediment is measured at 30 locations with the measuring time of one month, but with calculations for 24 hours • CO is measured at 4 locations (crossroads) with measurement period 2x7 days during spring and autumn • Lead is measured at one location (near institute) with measurements of 2 times per year for seven days (spring and autumn)

  9. Public Health Institute - Veles • SO2 is measured at 3 measuring points • Black smoke is measured at 3 measuring points • aerosediment is measured at 7 measuring points in the City Public Health Institute in Kumanovo, Kocani, Tetovo, Bitola, Ohrid, Prilep and Stip monitor aerosediment

  10. Ministry of Environment and Physical Planning At present, the Ministry of Environment and Physical Planning has: • 13 fix automatic air quality monitoringstations, • one mobile station, • one traffic air pollution monitoring station.

  11. State automatic air quality monitoring system

  12. State automatic air quality monitoring system Automatic air quality monitoring stations measure environmental and meteorological parameters. Measured environmental parameters include: • CO-carbon monoxide expressed in mg/m3 • SO2-sulphur dioxide expressed inmg/m3 • Nitrogen oxides expressed inmg/m3 • O3 - ozone, expressed inmg/m3 • PM10 - suspended particulate matters in air with size below 10 microns, also expressed inmg/m3 • BTX - benzene, toluene, ethyl-benzene, otoxylene, paraxylene

  13. State automatic air quality monitoring system Measured Meteorological parameters include: • Wind velocity, expressed in m/s • Wind direction, expressed in degrees • temperature, expressed in Celsius degrees • humidity, expressed in % • pressure, expressed in hPa • global radiation, expressed in W/m2

  14. State automatic air quality monitoring system THERMO Electron Corporation Measuring methodologies: • The Model 43C pulsed fluorescence SO2 analyzer • The Model 42C Chemiluminescence NO-NO2-NOx analyzer • The Model 48C Gas Filter Correlation (GFC) CO analyzer (infrared absorption) • The Model 49C UV photometric ozone analyzer • PM analyzer: FH 62 I-R; b-ray absorption

  15. State automatic air quality monitoring system • DAS (Data Acquisition system) software in each monitoring station • Telephone line • CAS (Central Acquisition system) software in central station

  16. Calibration Laboratory • Established in May 2004

  17. Calibration Laboratory

  18. Low volume samplers • 6 LVS PM10 (low volume samplers) were installed in April 2005

  19. High volume samplers • 4 HVS PM10 (high volume samplers) were installed in April 2005

  20. Data processing and information • In case, at certain measuring point, individual pollutant exceeds the average hourly maximum concentration for three hours consecutively, the State Inspectorate of Environment is informed and alerted. • Information of City Centre for Information and Warning • Monthly report from the State Automatic Air Quality Monitoring System • Annual report of all processed air quality data • Development of popular brochures on air topics

  21. Reporting obligation for Macedonia regarding the Air quality

  22. Reporting obligation for Macedonia regarding the Air quality