1 / 73

JA-80

JA-80. Make your premises an Oasis of security. JA-80_EN_042007 _c1. A solution for your security & comfort. Oasis basic features:. 50 addresses for wireless devices (detectors, RC, keypads and sirens) 50 positions for user codes or/and proxy cards

yves
Download Presentation

JA-80

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JA-80 Make your premises an Oasis of security JA-80_EN_042007_c1

  2. A solution for your security & comfort......

  3. Oasis basic features: • 50 addresses for wireless devices (detectors, RC, keypads and sirens) • 50 positions for user codes or/and proxy cards • 2 wired inputs in the control panel ( plus Inputs in keypad and detectors) • Lithium batteries – calculated lifetime 3 years • 868 MHz operating frequency • Grade 2 by the EN 50131 standard (medium risk)

  4. “LEGO” architecture

  5. JK-81 kit • Devices supplied pre-enrolled and pre-programmed • Simple installation

  6. JK-81 consists of: • Control panel with GSM communicator • Wireless keypad • PIR detector • Magnetic detector • Indoor siren • Key fob • Wireless door bell button • Proximity card • Accessories (batteries etc.)

  7. Installation in 7 steps 5 6 1 4 7 3 2

  8. Service mode after powering up • A:Enrollment ofmore devices • key 1and connect batteries, exitwith # • B: Communication quality test • key298 (turns on signal measurement) • arrow keys scroll devices • device triggering = signal from 1/4 to 4/4 • # returns you to Service mode • C:GSM signal strength test • key922 • return to Service mode by # • Each signal should be at least 2/4

  9. Programming Example: 4 hh mm DD MM YY= clock 201Exit delay 10sec. 81 1 777 775 022*0= tel. number 9261= forward SMS

  10. 299 enrollment of PGX to AC relay X • 237 PGX function = on / off

  11. Handover to the user

  12. Operating a key-fob SET (arm) UNSET (disarm) Both buttons = PANIC

  13. Keypad layout Alarm or faultSET A, B and C Power Details Setting (arming) Hot keys A, B & C PGX On / Off Detail reading

  14. Let the user feel that (s)he is the master • „Master“ card enrollment: * 5 1234card • Access card enrollment: * 6, Master card, keynn, card • Access code programming: * 6, Master card, keynn, code • To erase access code and card: * 6, Master card, keynn, 0000 nn= user number 01 to 50 Each user can have code, card or both John 2375

  15. Keypad operation

  16. * instructions

  17. 2 level partial arming Example:Family house C KeyA A Evening arming Garage…. A A B C Key B A+B Night arming Ground floor + garage A B C Key ABC A+B+C C A B Complete arming A B

  18. Split system Example: Two families in a house A B Code or card Bush Bush ARMED C Code or card Blair A B Blair ARMED C If both A+B armed, then C also armed A B Entire house armed incl. Common section C

  19. Communicator test Both buttons PANIC Panic alarm SMS Result: • Function test • Knowing the SIM card tel. number

  20. Remote access testing Phone keypad authorization: • Call and wait for the system to respond (after 5 rings) • Enter a valid code (master, user or service) • Operate the system… hang up at the end SMS instructions: „CodespaceINSTRUCTION“

  21. Control panel JA-80K • Features 1: • Back up battery 1.3Ah or 2.6Ah • Standby consumption 50 mA • Outputs: • EW - external warning (dry contact, max. 1A) • IW - internal warning (switches to GND, max. 0.5A) • PGX & PGY (switch to GND max. 0.2A) • +U power, max. 0.4A • Built in transceiver • Optional external antenna • Up to 50 wireless devices • Selectable reactions (Naturalor others) • Assignment to sections (A, B, C) • All devices have natural reaction in section C as factory-default • Devices can also be enrolled by keying in their production codes

  22. Control panel JA-80K • Hard-wired inputs (addresses 01 and 02) • Maximum of 5 detectors in a loop, • Differentiates between triggering and tampering • Programmable reaction (Natural = delayed) • Enrollment of a wireless device to address 01 or 02 disables the input terminal • Connected to COM via a 1 k resistor = untriggered input • Connected to COM via 2 to 5 k = triggered input, • Connected to COM via less then 700 or more then 7k8 k = tamper signal

  23. Control panel JA-80K • Features2: • Two-level partial setting (A, AB, ABC) • Or split system: A, B and C (common section) • Devicesand codes/cardscan have reactions: Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset • Up to 5 final-door detectors • Intruder alarm confirmation by a 2nd detector • Annual inspection request indication option • Indication of permanently triggered detectors (details by ? key) • Winter/Summer time automatic change (1st of November/1st of April) • Memoryfor the last 255 events • Replaceable memory chip • Can be operated with up to: • 50 user codes (locally or remotely by phone or internet) • 50 user cards • Option: Confirmation of the card by code

  24. The JA-80F keypad • LCD (2x 16 characters) • 1stline = status or event • 2nd line = name of the event source • Keypad menu – 15 languages and Chime feature • Built in proximity card readers Hard-wired input IN (NC, Natural reaction = Delayed) • Arrow keys allow you to control PGX (*81 and*80) A, B & ABCarming hot keys ?Detail reading • Keypad turns off after 20sec (if battery powered) • 2 x AA Lithium 3V batteries(3 year lifetime- 2 operations/day) • JA-80E= hard-wired version

  25. Keypad text editing • In service mode: • Holding?pressed opens editing • Keys: Arrow – selects the text string to be edited 1 and 7 - scroll through characters (A, B, C…..8,9,0) 4 and 5 - move cursor 2 deletes character # exits editing Comlink SW allows more convenient editing (special signs / letters enabled) - keypad must be connected to the control panel bus

  26. The PC-01 proximity card • RFID access card(EM UNIQUE 125kHz) • Up to 50 cards can be enrolled to the system • The card has the same function as an access code • For higher security the card can be combined with a code • PC-02 is a key tag version

  27. The JA-80H outdoor keypad • Built in RFID reader • Connects to the control panel bus via WJ-80 • Provides a doorbell button • Illuminated keys • IP-65 • Standby consumption 45mA

  28. The JA-80Noutdoor reader • RFID card reader • Connects to the control panel bus via WJ-80 • IP-65 • Standby consumption 40 mA

  29. The WJ-80 interface • Connects outdoor keypad (reader) to the control panel • Built-in door bell transmitter (for JA-80L) • Output to operate an electrical door lock (Z8-12V) • Provides output to operate the electric strike of an electrical door lock an open button input • Keypad uses Wiegand protocol 26b • DIP switches: • System keypad / Outdoor bypass switch • PGY can operate the door lock as well (Y/N) • Door lock activation time 3 / 6 seconds • Exit & entrance beeps (Y/N) Sequence 248 = PGY pulse Authorized phone opening 777 775 022*9 To program 81 1 777 775 022 *79*0 Control panel bus

  30. The RC-80 key-fob • 2 housings provided (2 or 4 buttons) • Key lock (4 buttons only) • Can also be used with UC, AC, JA-80L an CA-180x • Alkaline battery 6V, life time 2 to 3 years • Working range up to 100m

  31. The RC-88 button • DIP switches: • Panic (remote control or panic button function) • TMP (disable tamper sensors and communication supervision) • Can also be used with UC, AC and JA-80L • 1x 1/2 AA Lithium 3V battery (3 year life time, max. 20 activations/day)

  32. The RC-89 door bell button • Works withthe JA-80L indoor siren • Can be enrolled to the control panel as a portable panic button (by keeping pressed for 3 seconds) • Can also be used with AC and UC modules • No radio communication supervision • 6V alkaline battery • Working range up to 200m Mr. Jones

  33. The RC-87personal panic button • Can be enrolled to the control panel, siren or UC/AC modules • Optional • Wrist watch or necklace version • Audible confirmation of triggering • Delay (10s) to stop accidental triggering • No radio communication supervision • CR2032 lithium battery • Working range up to 200m HW in testing

  34. The RC-85 remote control module • Designed to be installed in a car (from 12V to 24V) • 3 wires • GND • A = if connected to +Utransmits signal • B = if connected to +U transmits signal • both A + B connected to +Utransmits a panic signal • Works with the control panel, UC, AC and JA-80L • No battery, powered by car • Flashing full-beam headlights or blowing the horn send signals • Can also be used to transmit an alarm from a car alarm • Optional to choose “double click” activation

  35. The JA-80P detector • PIR sensor • Hard-wired input IN(initiate same reaction as PIR) • 15 min test mode after closing the cover • 5min sleep time(can be shortened to 1 minute) • DIP switches • DEL / INS (natural reaction) • NORM / HIGH (immunity level) • Covers 120° / 12m • Optional lenses(pet, long corridor, vertical curtain) • 1 x AA Lithium battery 3V (3 year life time)

  36. The JA-80PB detector • PIR sensor + glass-break sensor • Enrolls to 2 addresses in the system • PIR =identical to JA-80P • GB detection - up to 9m (GBT-212 tester) • 15 min test mode after cover closing • Glass-break DIP switches • DEL / INS (natural reaction) • PIR / GBS (LED indicator function in test mode) • 2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA

  37. The JA-84P detector & camera • PIR sensor + CMOS camera • PIR =identical to JA-80P • 2 way communication • Processing module in the control panel • If armed and a movement detected = takes pictures • 1st immediately without flash • 2nd & 3rd with flash • High resolution stored to internal memory (USB) • Low resolution sent to server (within 25sec) • 2 Lithium 3V batteries AA size Working samples

  38. The JA-89P detector • Outdoor PIR sensor • 2 sensors eliminate small animals • Adjustable detection angle • IP-54 cover • Installation height 0.8 - 1.2 m • 1 x AA Lithium battery 3V (3 year life time) • Based on the Optex product Working samples Covered area adjustable not covered area

  39. The JA-80M detector • Magnetic door / window detector • Status detector (optional pulse reaction) • DIP switches: • DEL / INS (natural reaction) • MG ON / MG OFF (enables/disables internal sensor) • 2 input terminals: • TMP = tamper input • IN = alarm input • 1x 1/2 AA Lithium 3V battery (3 yearlife time for 20 activations/day)

  40. The JA-82M detector • Invisible window (door) detector (EURO or wooden) • To be installed in the frame of a window (door) • DIP switches: • INS / DEL • TMP on / off • Status / pulse reporting • Communicating range up to 200 meters • 2 x CR2354 Lithium 3V battery (3 year life time 5 activations/day) A B Prototypes

  41. The JA-80S detector • Fire detector(optical smoke + temperature over 60°) • Testing by test button or by aerosol • Optional to disconnect siren by test button in alarm • Jumpers: • FIRE / INS (natural reaction) • SIREN ON / OFF (enables / disables internal siren) • 1x AA Lithium 3V battery (3 year life time)

  42. The JA-80G detector • Combustive gas or fume detector • Mains powered • Can be tested with a cigarette lighter • DIP switches: • 10 / 20% LEL (gas concentration) • MEM ON / OFF (memory function) • Output relay contact max. 6A Prototypes

  43. The JA-85P detector • Mini-size PIR detector • Can be used in a house or in a car (CA-1802 or 1803) • 15 min test mode after closing the cover • DIP switches • NORM / HIGH (immunity level) • DEL / INS (natural reaction) • Supervision ON / OFF • Sleep 1 / 5 minutes • Semi-sphere lens max. detection distance 5m • Communicating range up to 200 meters • 1 x AA Lithium 3V battery (3 year life time)

  44. The JA-85B detector • Mini-size glass-break detector • Can be used in a house or in a car (CA-1802 or 1803) • 15 min test mode after closing the cover • DIP switches • DEL / INS (natural reaction) • Supervision ON / OFF • Detection up to 9 meters (can be tested with GBT-212) • Communicating range up to 200 meters • 1 x AA Lithium 3V battery (3 year life time)

  45. The JA-80L indoor siren • Mains powered Tampering reported if disconnected from the power during an alarm = ALARM CONFIRMATION • Enrolls by plugging in • Generates sounds: • IW alarm • Exit and entrance beeps • Door bell - 8 melodies • Detector - triggered sounds - 8 melodies • LED indicates PGY status • Two volume levels (by keeping the button pressed) • Triple click enables/disables arming chirp sounds • Signal level measurement – by pressing button

  46. The JA-80A outdoor siren • Totally wire-free !!! • Loudness increases gradually • Max. duration of the siren sound: 3 min. • Flashes 30 min. after the alarm • Jumpers: • 50 / 25 s. (communication cycle with the control panel) • LED ON / OFF (warning flash every minute) • Enrolls by connecting its battery • Lithium battery BAT-80 (max. life time 3 to 5 years)

  47. The JA-80Y communicator • Communication via GSM/GPRS • GSM gateway function • Events reporting by: • SMS (15 lang. Selection) • phone calls • ARC (IP, SMS or CID protocols), ARC programming can be locked • Remote access via: • Phone (keypad registration or SMS) • Internet - www.gsmlink.cz • Unanswered ringing from an authorized phone number • ARC programming can be locked • Remote access possible with a valid code (UC, MC, SC)

  48. The JA-80Vcommunicator • Communication via LAN & PSTN • Events reporting by: • SMS (15 lang. selection) • phone calls • ARC (IP, CID or DRprotocols) ,ARC programming can be locked • Remote access via: • Phone (keypad registration or SMS) • Internet - www.gsmlink.cz • Unanswered ringing from an authorized phone number • Remote access possible with a valid code (UC, MC, SC) Combination of LAN and PSTN enables the same features as GSM / GPRS. Most of the JA-80V and JA-80Y functions are identical

  49. Events reporting Telephone network INTERNET and or Automatic Receiving Center User notification Oasis

  50. Remote access www.GSMLink.cz INTERNET and or Internet Telephone PC connected to Internet Remote access from Internet