slide1
Download
Skip this Video
Download Presentation
JA-80

Loading in 2 Seconds...

play fullscreen
1 / 73

JA-80 - PowerPoint PPT Presentation


  • 76 Views
  • Uploaded on

JA-80. Make your premises an Oasis of security. JA-80_EN_042007 _c1. A solution for your security & comfort. Oasis basic features:. 50 addresses for wireless devices (detectors, RC, keypads and sirens) 50 positions for user codes or/and proxy cards

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' JA-80' - yves


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

JA-80

Make your premises an Oasis of security

JA-80_EN_042007_c1

slide3

Oasis basic features:

  • 50 addresses for wireless devices (detectors, RC, keypads and sirens)
  • 50 positions for user codes or/and proxy cards
  • 2 wired inputs in the control panel ( plus Inputs in keypad and detectors)
  • Lithium batteries – calculated lifetime 3 years
  • 868 MHz operating frequency
  • Grade 2 by the EN 50131 standard (medium risk)
slide5

JK-81 kit

  • Devices supplied pre-enrolled and pre-programmed
  • Simple installation
slide6

JK-81 consists of:

  • Control panel with GSM communicator
  • Wireless keypad
  • PIR detector
  • Magnetic detector
  • Indoor siren
  • Key fob
  • Wireless door bell button
  • Proximity card
  • Accessories (batteries etc.)
slide8

Service mode after powering up

  • A:Enrollment ofmore devices
  • key 1and connect batteries, exitwith #
  • B: Communication quality test
  • key298 (turns on signal measurement)
  • arrow keys scroll devices
  • device triggering = signal from 1/4 to 4/4
  • # returns you to Service mode
  • C:GSM signal strength test
  • key922
  • return to Service mode by #
  • Each signal should be at least 2/4
slide9

Programming

Example:

4 hh mm DD MM YY= clock

201Exit delay 10sec.

81 1 777 775 022*0= tel. number

9261= forward SMS

slide10

299 enrollment of PGX to AC relay X

  • 237 PGX function = on / off
slide12

Operating a key-fob

SET

(arm)

UNSET

(disarm)

Both buttons = PANIC

slide13

Keypad layout

Alarm or faultSET A, B and C Power

Details

Setting (arming)

Hot keys

A, B & C

PGX

On / Off

Detail reading

slide14

Let the user feel that (s)he is the master

  • „Master“ card enrollment:

* 5 1234card

  • Access card enrollment:

* 6, Master card, keynn, card

  • Access code programming:

* 6, Master card, keynn, code

  • To erase access code and card:

* 6, Master card, keynn, 0000

nn= user number 01 to 50

Each user can have code, card or both

John

2375

2 level partial arming
2 level partial arming

Example:Family house

C

KeyA

A

Evening arming

Garage….

A

A

B

C

Key B

A+B

Night arming

Ground floor + garage

A

B

C

Key ABC

A+B+C

C

A

B

Complete arming

A

B

split system
Split system

Example: Two families in a house

A

B

Code or card

Bush

Bush

ARMED

C

Code or card

Blair

A

B

Blair

ARMED

C

If both A+B armed,

then C also armed

A

B

Entire house armed

incl. Common section

C

slide19

Communicator test

Both buttons

PANIC

Panic alarm SMS

Result:

  • Function test
  • Knowing the SIM card tel. number
slide20

Remote access testing

Phone keypad authorization:

  • Call and wait for the system to respond (after 5 rings)
  • Enter a valid code (master, user or service)
  • Operate the system… hang up at the end

SMS instructions: „CodespaceINSTRUCTION“

slide21

Control panel JA-80K

  • Features 1:
  • Back up battery 1.3Ah or 2.6Ah
  • Standby consumption 50 mA
  • Outputs:
    • EW - external warning (dry contact, max. 1A)
    • IW - internal warning (switches to GND, max. 0.5A)
    • PGX & PGY (switch to GND max. 0.2A)
    • +U power, max. 0.4A
  • Built in transceiver
  • Optional external antenna
  • Up to 50 wireless devices
    • Selectable reactions (Naturalor others)
    • Assignment to sections (A, B, C)
    • All devices have natural reaction in section C as factory-default
    • Devices can also be enrolled by keying in their production codes
slide22

Control panel JA-80K

  • Hard-wired inputs (addresses 01 and 02)
  • Maximum of 5 detectors in a loop,
  • Differentiates between triggering and tampering
  • Programmable reaction (Natural = delayed)
  • Enrollment of a wireless device to address 01 or 02 disables the input terminal
    • Connected to COM via a 1 k resistor = untriggered input
    • Connected to COM via 2 to 5 k = triggered input,
    • Connected to COM via less then 700 or more then 7k8 k = tamper signal
slide23

Control panel JA-80K

  • Features2:
  • Two-level partial setting (A, AB, ABC)
  • Or split system: A, B and C (common section)
  • Devicesand codes/cardscan have reactions:

Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset

  • Up to 5 final-door detectors
  • Intruder alarm confirmation by a 2nd detector
  • Annual inspection request indication option
  • Indication of permanently triggered detectors (details by ? key)
  • Winter/Summer time automatic change (1st of November/1st of April)
  • Memoryfor the last 255 events
  • Replaceable memory chip
  • Can be operated with up to:
    • 50 user codes (locally or remotely by phone or internet)
    • 50 user cards
    • Option: Confirmation of the card by code
slide24

The JA-80F keypad

  • LCD (2x 16 characters)
    • 1stline = status or event
    • 2nd line = name of the event source
  • Keypad menu – 15 languages and Chime feature
  • Built in proximity card readers Hard-wired input IN (NC, Natural reaction = Delayed)
  • Arrow keys allow you to control PGX (*81 and*80)

A, B & ABCarming hot keys

?Detail reading

  • Keypad turns off after 20sec (if battery powered)
  • 2 x AA Lithium 3V batteries(3 year lifetime- 2 operations/day)
  • JA-80E= hard-wired version
slide25

Keypad text editing

  • In service mode:
  • Holding?pressed opens editing
  • Keys:

Arrow – selects the text string to be edited

1 and 7 - scroll through characters (A, B, C…..8,9,0)

4 and 5 - move cursor

2 deletes character

# exits editing

Comlink SW allows more convenient editing (special signs / letters enabled) - keypad must be connected to the control panel bus

slide26

The PC-01 proximity card

  • RFID access card(EM UNIQUE 125kHz)
  • Up to 50 cards can be enrolled to the system
  • The card has the same function as an access code
  • For higher security the card can be combined with a code
  • PC-02 is a key tag version
slide27

The JA-80H outdoor keypad

  • Built in RFID reader
  • Connects to the control panel bus via WJ-80
  • Provides a doorbell button
  • Illuminated keys
  • IP-65
  • Standby consumption 45mA
slide28

The JA-80Noutdoor reader

  • RFID card reader
  • Connects to the control panel bus via WJ-80
  • IP-65
  • Standby consumption 40 mA
slide29

The WJ-80 interface

  • Connects outdoor keypad (reader) to the control panel
  • Built-in door bell transmitter (for JA-80L)
  • Output to operate an electrical door lock (Z8-12V)
  • Provides output to operate the electric strike of an electrical door lock an open button input
  • Keypad uses Wiegand protocol 26b
  • DIP switches:
      • System keypad / Outdoor bypass switch
      • PGY can operate the door lock as well (Y/N)
      • Door lock activation time 3 / 6 seconds
      • Exit & entrance beeps (Y/N)

Sequence

248 = PGY pulse

Authorized phone opening

777 775 022*9

To program

81 1 777 775 022 *79*0

Control panel bus

slide30

The RC-80 key-fob

  • 2 housings provided (2 or 4 buttons)
  • Key lock (4 buttons only)
  • Can also be used with UC, AC, JA-80L an CA-180x
  • Alkaline battery 6V, life time 2 to 3 years
  • Working range up to 100m
slide31

The RC-88 button

  • DIP switches:
    • Panic (remote control or panic button function)
    • TMP (disable tamper sensors and communication supervision)
  • Can also be used with UC, AC and JA-80L
  • 1x 1/2 AA Lithium 3V battery

(3 year life time, max. 20 activations/day)

slide32

The RC-89 door bell button

  • Works withthe JA-80L indoor siren
  • Can be enrolled to the control panel as a portable panic button (by keeping pressed for 3 seconds)
  • Can also be used with AC and UC modules
  • No radio communication supervision
  • 6V alkaline battery
  • Working range up to 200m

Mr. Jones

slide33

The RC-87personal panic button

  • Can be enrolled to the control panel, siren or UC/AC modules
  • Optional
    • Wrist watch or necklace version
    • Audible confirmation of triggering
    • Delay (10s) to stop accidental triggering
  • No radio communication supervision
  • CR2032 lithium battery
  • Working range up to 200m

HW in testing

slide34

The RC-85 remote control module

  • Designed to be installed in a car (from 12V to 24V)
  • 3 wires
    • GND
    • A = if connected to +Utransmits signal
    • B = if connected to +U transmits signal
    • both A + B connected to +Utransmits a panic signal
  • Works with the control panel, UC, AC and JA-80L
  • No battery, powered by car
  • Flashing full-beam headlights or blowing the horn send signals
  • Can also be used to transmit an alarm from a car alarm
  • Optional to choose “double click” activation
slide35

The JA-80P detector

  • PIR sensor
  • Hard-wired input IN(initiate same reaction as PIR)
  • 15 min test mode after closing the cover
  • 5min sleep time(can be shortened to 1 minute)
  • DIP switches
    • DEL / INS (natural reaction)
    • NORM / HIGH (immunity level)
  • Covers 120° / 12m
  • Optional lenses(pet, long corridor, vertical curtain)
  • 1 x AA Lithium battery 3V (3 year life time)
slide36

The JA-80PB detector

  • PIR sensor + glass-break sensor
  • Enrolls to 2 addresses in the system
  • PIR =identical to JA-80P
  • GB detection - up to 9m (GBT-212 tester)
  • 15 min test mode after cover closing
  • Glass-break DIP switches
    • DEL / INS (natural reaction)
    • PIR / GBS (LED indicator function in test mode)
  • 2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA
slide37

The JA-84P detector & camera

  • PIR sensor + CMOS camera
  • PIR =identical to JA-80P
  • 2 way communication
  • Processing module in the control panel
  • If armed and a movement detected = takes pictures
    • 1st immediately without flash
    • 2nd & 3rd with flash
    • High resolution stored to internal memory (USB)
    • Low resolution sent to server (within 25sec)
  • 2 Lithium 3V batteries AA size

Working samples

slide38

The JA-89P detector

  • Outdoor PIR sensor
  • 2 sensors eliminate small animals
  • Adjustable detection angle
  • IP-54 cover
  • Installation height 0.8 - 1.2 m
  • 1 x AA Lithium battery 3V (3 year life time)
  • Based on the Optex product

Working samples

Covered area adjustable not covered area

slide39

The JA-80M detector

  • Magnetic door / window detector
  • Status detector (optional pulse reaction)
  • DIP switches:
    • DEL / INS (natural reaction)
    • MG ON / MG OFF (enables/disables internal sensor)
  • 2 input terminals:
    • TMP = tamper input
    • IN = alarm input
  • 1x 1/2 AA Lithium 3V battery

(3 yearlife time for 20 activations/day)

slide40

The JA-82M detector

  • Invisible window (door) detector (EURO or wooden)
  • To be installed in the frame of a window (door)
  • DIP switches:
    • INS / DEL
    • TMP on / off
    • Status / pulse reporting
  • Communicating range up to 200 meters
  • 2 x CR2354 Lithium 3V battery

(3 year life time 5 activations/day)

A

B

Prototypes

slide41

The JA-80S detector

  • Fire detector(optical smoke + temperature over 60°)
  • Testing by test button or by aerosol
  • Optional to disconnect siren by test button in alarm
  • Jumpers:
    • FIRE / INS (natural reaction)
    • SIREN ON / OFF (enables / disables internal siren)
  • 1x AA Lithium 3V battery (3 year life time)
slide42

The JA-80G detector

  • Combustive gas or fume detector
  • Mains powered
  • Can be tested with a cigarette lighter
  • DIP switches:
    • 10 / 20% LEL (gas concentration)
    • MEM ON / OFF (memory function)
  • Output relay contact max. 6A

Prototypes

slide43

The JA-85P detector

  • Mini-size PIR detector
  • Can be used in a house or in a car (CA-1802 or 1803)
  • 15 min test mode after closing the cover
  • DIP switches
    • NORM / HIGH (immunity level)
    • DEL / INS (natural reaction)
    • Supervision ON / OFF
    • Sleep 1 / 5 minutes
  • Semi-sphere lens max. detection distance 5m
  • Communicating range up to 200 meters
  • 1 x AA Lithium 3V battery

(3 year life time)

slide44

The JA-85B detector

  • Mini-size glass-break detector
  • Can be used in a house or in a car (CA-1802 or 1803)
  • 15 min test mode after closing the cover
  • DIP switches
    • DEL / INS (natural reaction)
    • Supervision ON / OFF
  • Detection up to 9 meters (can be tested with GBT-212)
  • Communicating range up to 200 meters
  • 1 x AA Lithium 3V battery

(3 year life time)

slide45

The JA-80L indoor siren

  • Mains powered

Tampering reported if disconnected from the power during an alarm = ALARM CONFIRMATION

  • Enrolls by plugging in
  • Generates sounds:
    • IW alarm
    • Exit and entrance beeps
    • Door bell - 8 melodies
    • Detector - triggered sounds - 8 melodies
  • LED indicates PGY status
  • Two volume levels (by keeping the button pressed)
  • Triple click enables/disables arming chirp sounds
  • Signal level measurement – by pressing button
slide46

The JA-80A outdoor siren

  • Totally wire-free !!!
  • Loudness increases gradually
  • Max. duration of the siren sound: 3 min.
  • Flashes 30 min. after the alarm
  • Jumpers:
    • 50 / 25 s. (communication cycle with the control panel)
    • LED ON / OFF (warning flash every minute)
  • Enrolls by connecting its battery
  • Lithium battery BAT-80 (max. life time 3 to 5 years)
slide47

The JA-80Y communicator

  • Communication via GSM/GPRS
  • GSM gateway function
  • Events reporting by:
    • SMS (15 lang. Selection)
    • phone calls
    • ARC (IP, SMS or CID protocols), ARC programming can be locked
  • Remote access via:
    • Phone (keypad registration or SMS)
    • Internet - www.gsmlink.cz
    • Unanswered ringing from an authorized phone number
  • ARC programming can be locked
  • Remote access possible with a valid code (UC, MC, SC)
slide48

The JA-80Vcommunicator

  • Communication via LAN & PSTN
  • Events reporting by:
    • SMS (15 lang. selection)
    • phone calls
    • ARC (IP, CID or DRprotocols) ,ARC programming can be locked
  • Remote access via:
    • Phone (keypad registration or SMS)
    • Internet - www.gsmlink.cz
    • Unanswered ringing from an authorized phone number
  • Remote access possible with a valid code (UC, MC, SC)

Combination of LAN and PSTN enables the same features as GSM / GPRS.

Most of the JA-80V and JA-80Y functions are identical

slide49

Events reporting

Telephone network

INTERNET

and

or

Automatic

Receiving

Center

User

notification

Oasis

slide50

Remote access

www.GSMLink.cz

INTERNET

and

or

Internet

Telephone

PC connected to Internet

Remote access from Internet

slide51

The JA-80X voice communicator

  • Reports alarms with voice messages
  • Up to 4 phone numbers via PSTN
  • 7voice messages
    • System name
    • Intrusion
    • Fire
    • Tampering
    • Panic
    • Technical alarm
    • Remote access welcome note
  • Allows remote access via telephone keypad authorization (DTMF)
  • Supports CID protocol transmission to ARC (PSTN line)
  • Can be combined with JA-80V or JA-80Y

Prototype

slide52

The SP-02 speaker phone

  • For listening in and talking
  • Can be connected to PSTN or to the phone line simulated by JA-80Y
  • Answers calls from authorized numbers
  • Half-duplex communication allows a high sensitivity for listening
  • Push-to-talk feature to call an emergency number
  • 2 x AA alkaline 1.5V battery

Prototype

slide53

The UC-82 relay module

  • Powered by 12V DC
  • 2 output relays (X & Y) - max 2A
  • Low bat. output
  • External antenna is optional
  • Powered by 12V (20mA) external source
  • Can be used with:
    • Control panel
    • Detectors
    • RC-8x transmitters
slide54

The AC-82 relay module

  • Powered directly from mains 230V, 50Hz
  • 2 output relays (X and Y) - max 5A
  • Can be used with:
    • Control panel
    • Detectors
    • RC-8x transmitters
    • TP-8x thermostats
slide55

The TP-80 thermostat

  • Enrolls to AC-82
  • Transmits signals:
    • Temperature below target (normal heating)
    • Below 6°C (anti-freezing)
    • Below 3°C (Freezing alarm - Panic)
    • Above 60°C (Fire alarm)
    • Supervision and battery status
  • Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors
  • 1 AA alkaline battery 1.5V, 1 year lifetime
slide56

The TP-82 thermostat

  • Enrolls to AC-82
  • Indicates temperature
  • Transmits signals:
    • Temperature below target (normal heating)
    • Below 6°C (anti-freezing)
    • Below 3°C (Freezing alarm - panic)
    • Above 60°C (Fire alarm)
    • Supervision and battery status
  • Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors
  • 1 AA alkaline battery 1.5V, 1 year life time

TP-83 weekly temperature programming ( 3Q 2007)

slide57

Simple heating control

Thermostat is enrolled to the AC receiver

Radio

Cable

AC-82

Thermostat

slide58

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Thermostat is enrolled to the AC receiver and also to the control panel

slide59

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Normal heating control

Heating = ON

slide60

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Operating heating by remote controls

ON = normal heating

OFF = anti-freezing heating only

slide61

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Operating the heating by keypad

ON = normal heating

OFF = anti freezing heating only

slide62

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Operating the heating by a phone

ON = normal heating

OFF = anti freezing heating only

slide63

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Operating the heating by windows

CLOSED = normal heating

OPEN = anti freezing heating only

slide64

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Robbery ALARM !!!!

slide65

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Freezing ALARM !!!!

(heating is defective)

slide66

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Fire ALARM !!!!

(temperature above 60 °C )

slide67

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Low battery in thermostat

slide68

Smart heating system

Remote controls

Window detectors

Control panel

Thermostat

AC-82

Telephone

Heating

Communication lost with thermostat

slide69

OASiS brings security and comfort

“Many useful and intuitive features are hidden within the system, disturbing neither the installer nor the end user….”

slide70

The UC-8014 multiple channel receiver

  • Power 230V AC
  • 7 to 28 outputs
  • Extra output for circulation pump
  • Enrolls:
    • thermostats
    • RC controllers
    • window detectors
    • control panel PG outputs

Designed for larger heating systems (floor heating systems and etc.)

slide71

Optional antennas

Can be used with:

  • Control panel
  • UC-82

AN-80

AN-81

slide72

The JA-80T PC cable

  • Connects control panel to PC
  • Provides USB interface
  • Suitable for Comlink 80 and higher
  • JA-80BT (Bluetooth option - 2007)
slide73

Comlink 80

  • Compatible with JA-6x and JA-80
ad