1 / 17

Ohio Code Data Plates: Elevator Orders and Requirements

This article discusses the ordering process for Ohio elevator code data plates, including requirements for elevator companies, building owners & managers, and retail orders. It also covers the different editions of the Ohio code and the information needed for different types of installations.

yul
Download Presentation

Ohio Code Data Plates: Elevator Orders and Requirements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ohio Code Data Plates Past 8 Months • Orders from Elevator Companies • Many are ordering Standards in quantity • A few only give State ID • Slows process as we must call in to establish edition • Most do provide State ID and Edition Information • Very few are providing any Alteration Information • Several classes given to office staff and mechanics • Orders from Building Owners & Managers • As of November 2005 we began to see Retail Orders • Pay higher price and also must pay Ohio Sales Tax • Most require research or verification to complete • State records • Elevator contractor assistance

  2. Ohio Standard Plates • All Adopted Code Editions Standard 1 - Ohio Red Book

  3. Note the “s” Would this plate be appropriate for all installations?

  4. Modernization • Alterations done under the A17.1-1996 Edition • Always follows Rules in Standard 13 (a-1997) • Alterations under A17.1-2000 and later Editions • Follows the 8.7 Requirements of the Alteration Edition

  5. Reading the Plate Door Operator Plunger Gripper Wiring Valve Pump Unit Re-opening Devise Tank Door Restrictor Limits Controller Replacement Top of Car Insp.. Emergency Operations Leveling

  6. Internal Worksheets for Custom Plates

  7. Custom Plates • Modernizations • Multi-mod Plate

  8. Custom Plates • Add-on Plates

  9. Alteration Not Listed • 8.7.4 - Other Types of Driving Machines • 8.7.5 - Special Application Elevators • 8.7.7 - Dumbwaiters and Material Lifts Limits Special Purpose Personnel Elevators Driving Machine Operation Emergency Signal and/or Communication

  10. Alteration Not Listed • No Equivalent Part XII Rule • 8.7.2.11.5 - Door Restrictors • 8.7.20 - Rope Gripper • 8.7.3.23.7 - Plunger Gripper • 8.7.3.31.9 - Emergency Lowering 1201.11 (or 1203.1k) requires compliance with Rule 111.5

  11. Alteration Not Listed • No Equivalent Part XII Rule - use 1200.2 & • 8.7.20 - Rope Gripper • 8.7.3.23.7 - Plunger Gripper • 8.7.3.31.9 - Emergency Lowering

  12. Other Alteration Plates • Car Weight ( On Crosshead) • Car Speed (On Governor)

  13. Other Plates • Missing Cross Head Plate • Temperature Humidity Plate (2.7.5.2)

  14. Other Issues • Non-Conforming • Missing Plates • No Alterations Recorded • Magic Marker Plates • Paper Plates • Blank Plates • Mounting Locations • Main Line or Controller only • Groups on Single Plate • Must Identify all Units by State ID

  15. Thank You Questions Suggestions Pocket Code

More Related