  • Presentation posted in: General

LCLS Machine Protection System. Overview Interim MPS Full LCLS MPS Design Schedule. Interim MPS. Presented at last FAC Hardware and software installed and tested Running as MPS for injector commissioning Capable as MPS for BC2 commissioning Does not meet LTU/Undulator MPS requirements.

Download Presentation

LCLS Machine Protection System

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Lcls machine protection system

LCLS Machine Protection System

  • Overview

    • Interim MPS

    • Full LCLS MPS Design

    • Schedule


Interim mps

Interim MPS

  • Presented at last FAC

  • Hardware and software installed and tested

  • Running as MPS for injector commissioning

  • Capable as MPS for BC2 commissioning

  • Does not meet LTU/Undulator MPS requirements


Full mps design

Full MPS Design

  • Flexible Software Based System

    • Easily reprogrammable flexible logic

    • Rate limiting on fault severity (PICs)

    • Monitoring of EVG

    • Upgradeable hardware modules

  • Simple Hardware Based System

    • Secure second path of shutting off beam in response to an obstruction or major fault


Flexible software based system

Flexible Software Based System

  • MVME 6100

  • Reflective Memory

  • Latching Digital Input Card

  • Digital Output Card

  • Two classes

    • Decision Module

    • Input Multiplexer


Flexible software based system1

Flexible Software Based System


Simple hardware based system

Simple Hardware Based System

  • Based on Argonne Design

  • ColdFire CPU

  • Altera FPGA

  • 10 MHz tones

  • Creates a Networked TIU (NTIU)

  • Remotely Bypassable

  • EPICS Ready


Simple hardware based system1

Simple Hardware Based System


Schedule

Schedule