Calibration System with Cryogenically-Cooled Loads for QUIET-II Detector

Calibration System with Cryogenically-Cooled Loads for QUIET-II Detector . M. Hasegawa, O. Tajima, Y. Chinone , M. Hazumi , K. Ishidoshiro , M. Nagai High Energy Accelerator Research Organization, KEK . 2 . Detector and Characterization. 1 . QUIET Phase-II. QUIET Detector .

yepa
Download Presentation

Calibration System with Cryogenically-Cooled Loads for QUIET-II Detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calibration System with Cryogenically-Cooled Loads for QUIET-II Detector M. Hasegawa, O. Tajima, Y. Chinone, M. Hazumi, K. Ishidoshiro, M. Nagai High Energy Accelerator Research Organization, KEK 2. Detector and Characterization 1. QUIET Phase-II • QUIET Detector The Q/U Imaging Experiment (QUIET) is an experimental program to make very sensitive measurement of the Cosmic Microwave Background (CMB) polarization from the ground. The primary goal is to detect the degree-scale B-modes induced by primordial gravitational waves, which is a “smoking gun” signature of inflation. Having demonstrated our techniques in the first phase, we are preparing for the second phase of QUIET with ~500 detectors. One of new challenges towards QUIET Phase-II is to (precisely) characterize the large number of detectors in the laboratory, and the calibration system reported here is newly developed for that purpose. OMT QUIET employs a HEMT-based pseudo-correlation receiver. A large focal-plane detector array is realized by a breakthrough in millimeter-wave circuit technology and packaging at JPL. HEMT • Pseudo Correlation Detector • - Measure Q/U polarization simultaneously • - Stable against gain fluctuation • Modulation (Phase switching) • - 1/f noise is strongly suppressed. • - Cancel out fake pol. signals. 3cm • Characterization The following quantities should be characterized in order to convert detector time stream into polarization power spectra. - Detector responsivities (mK/mV) - Detector polarization angle - Instrumental fake polarization Well-characterized polarization signal is required. 4. System Components 3. Calibration System • Cryostat and cryocooler • Metal Mirror • All-in-one polarization source • - Blackbody emitters are cooled with a • cryocooler as the cold load (~10K) • - Radiation is polarized by reflecting off • a metal mirror • Use 3 different materials to vary the pol. Amplitude. • Rotate in the vacuum with rotary feed-through shaft. • Advantages • - Well-characterized polarization signal • Amplitude : • Direction : Parallel to the mirror surface • - Two temperature loads • Unpolarized response can be calibrated simultaneously • - Reproducing the observing condition (chilean sky load : ~10 K) • Cylindrical cryostat (D 540mm,H 500mm) • 2 stage GM cryocooler • - enable two temperature loads • - thermal loads is 18/7W on 1st/2nd stage in • normal operation. • Blackbody emitter array We employ Eccosorb CR-112 an iron-loaded epoxy as the material for the blackbody emitter. To minimize the surface reflection, loads are casted with pyramid-shape grooves on the front surface. The measured power coefficient is typically -30dB. This system allows us to calibrate all the necessary quantities to characterize the QUIET-II detector simultaneously under a load condition similar to the actual observation. Definitive test system for CMB polarization detector 6. Performance 5. Principle • Inherent polarization signal • Resistivity vs Signal • - Polarization signal • - Inherent pol. is signal at 0Ωcm • No inherent polarization signal. • Expected Response • Detector Response • Total Power • Two levels are seen as expected. • - 10K (upper) and 30K (lower) • Polarizaton • Clear sinusoidal curve • - Amplitude is as expected. 10K 30K • All the calibration parameters are extracted from the response with respect to the mirror rotation angle. • Responsivity (pol.) : Amplitude/P • Responsivity (power) : DVI / DTload • Polarization Angle • : Phase of the sinusoidal curve • Instrumental fake polarization • : DVQ,U / (RKDTload ) 6. Summary We have developed a polarization calibrator for QUIET-II detectors, and successfully demonstrated its use with an actual QUIET detector. This is the first demonstration “in the laboratory” for the modulation of the polarization signal with a load temperature, which is as low as those at the observing site.

More Related