An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Match UPSProduct ManagementJuly 2004

  2. Contents Range Topology Unique Selling Points Key Features Accessories Applications

  3. “Even a moment’s disruption can have devastating effects on power sensitive customers such as internet service providers, data centres, wireless telecommunications networks, on line traders, computer chip manufacturers and medical research centres. For these customers, power disruptions can result in data corruption, burned circuit boards, component damage, file corruption and lost customers.”- “Electrical Power Interruption Cost Estimates for Individual Industries, Sectors and US Economy” February 2002, US Dept of Energy, Office of Power Technologies “The system and its data can become corrupt as a result of power failure…a UPS can protect the system if power is lost. A UPS usually provides…temporary power which may be enough to permit a graceful shutdown”- Special Publication 800-34 Contingency Planning Guide for Information Technology Systems, National Institute of Standards and Technology, June 2002

  4. Range Models available include ⃘500, 700, 1000, 1500, 2200 & 3000VA tower models ⃘700, 1000, 1500, 2200 & 3000VA 19inch rackmount models ⃘Longer runtime (L) version for 700VA and 1000VA ⃘2200 and 3000VA with DC connector for additional batteries ⃘ Matching battery cabinets

  5. Boost Normal Control Inverter OUT Buck IN Battery AVR Relay Safety Relay Topology Line Interactive

  6. Topology A Line Interactive UPS provides: Battery back up and voltage stabilisation As well as providing back up power from the battery when the mains fails, the UPS filters the mains during normal operation, regulating the incoming voltage Cost effective UPS protection Lower price compared to on line UPS

  7. Topology A Line Interactive UPS provides: Small break in power During the switch from mains to battery, there is a small loss of power to the load (typically 2-4ms, not affecting most computer type loads) Medium degree of protection When compared to on line (double conversion) UPS

  8. Unique Selling Points Excellent High Voltage Protection The Match UPS will protect itself and the supported load up to 350VAC. Most UPS will damage themselves or the load if the input voltage exceeds 300V Low ‘Green’ Power Consumption Compared to other line interactive UPS, the power consumption is extremely low during normal operation

  9. Unique Selling Points Optimised Sinewave Output The output waveform is sinusoidal with a linear load, and with a crest load is slightly flattened. This avoids high current peaks on the electronics and the battery, and still provides high efficiency. This is the optimal solution between sinewave and stepwave UPS outputs. Stepwave UPS can cause some electronic equipment to malfunction.

  10. Additional USPs, Match 2200 & 3000 Extremely wide input voltage window At 165-275V (500-1500VA) and 140-305V (2200 & 3000VA), the output voltage is limited to 190-254V. This minimises the need for battery use, extending battery life Battery charging even at 140VAC Even in poor mains conditions there is a fast recovery of battery power, increasing up time and battery life High battery recharge current When additional battery packs are connected, the charger current automatically increases to 10A, ensuring much faster recharge time

  11. Additional USPs, Match 2200 & 3000 • Deep battery calibration test • The actual battery capacity can be tested and calibrated. This ensures the predicted runtime stays accurate throughout the life of the UPS • Load dependent end of discharge • If the discharge time is shorter, batteries may be discharged deeper. This features ensures maximum runtime is is given at any load level, without the risk of damaging the battery during longer power failures

  12. Key Features • Automatic voltage regulation • The buck and boost function minimises battery operation, increasing the battery life. With an inout voltage window of 165-275V, the output voltage is limited to 190-254V • Crest factor input acceptance 6:1 • The Match is especially suited for computer loads, and no oversizing is necessary

  13. Key Features • Battery start (cold start) • Allows the UPS to be switched on without mains power, for mobile applications or to perform a quick action during a mains failure • Extended communication • RS232, SNMP and contact interface communication (plug in options for Match 700L and above)

  14. Key Features – Superior Battery Management Automatic monthly battery testing Alerts the user that the batteries need to be replaced The UPS keeps running in normal operation over the test, rather than switching to battery. If the battery is damaged or empty, the load is still supported Safe battery test For areas with poor mains, ensures a faster recharge time than with float charge only Automatic boost charge Means that loads even in very poor mains areas can be supported more than once during a shift 2 hours battery recharge time Charger off at end of discharge period Prevents battery depletion beyond recharge capability Lowest battery temperature during mains operation The electronic design of the UPS means the battery temperature is very low, increasing battery life On battery at less than 5% load, the UPS performs an automatic shutdown to protect the battery. This function can be disabled No load shutdown

  15. SNMP Card ⃘ Can be used with Match 700L upwards ⃘ Presents UPS information across a network via: ⃘ SNMP Agent (one or more NMS can monitor, manage and control the UPS) ⃘ Web Server (UPS data in HTML format, so standard internet browser can be used to monitor UPS) ⃘ Easy installation through RS232 slot ⃘ SNMP box also available Accessories Network Protection Software ⃘ CD packed with UPS free of charge, with intelligent communication cable. ⃘ Simple installation ⃘ Virtually invisible operation under normal conditions ⃘ Provides a graceful shutdown of load after a lengthy mains failure ⃘ Supports all major operating systems ⃘ DataShield supplied for JAVA supported operating systems

  16. Relay Interface Card ⃘ Can be used with Match 700L upwards ⃘ Easily installed into CardConnect slot at rear of UPS ⃘ Provides 4 potential free contacts for: Mains failure General alarm Battery low Bypass active and a 9 pole Sub-D connector Accessories Manual Service Bypass ⃘ Contains a manual bypass switch ⃘ Allows for maintenance or testing of UPS with no interference to the protected load ⃘ Pluggable as standard, but can be hardwired using the internal terminal strip

  17. Applications PCs Servers Workstations Hubs, switches and routers Cash register systems (EPOS) Fax, modem, ISDN adaptors