1 / 93

Storage 사업부 고객지원팀

DF700 운영 매뉴얼. Storage 사업부 고객지원팀. Contents. 1. Theory. 2. Installation. 3. System Parameter. 4. Disk Recovery Guideline. 5. Part Replacement. 6. AMS200 to AMS500 Upgrade Procedures. Contents. 1. Theory. 2. Installation. 3. System Parameter. 4. Disk Recovery Guideline.

xander
Download Presentation

Storage 사업부 고객지원팀

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DF700 운영 매뉴얼 Storage사업부고객지원팀

  2. Contents 1. Theory 2. Installation 3. System Parameter 4. Disk Recovery Guideline 5. Part Replacement 6. AMS200 to AMS500 Upgrade Procedures

  3. Contents 1. Theory 2. Installation 3. System Parameter 4. Disk Recovery Guideline 5. Part Replacement 6. AMS200 to AMS500 Upgrade Procedures

  4. 1.Theory 1.1 RAID Technology RAID5에서 Stripe Size가 너무 작을 경우 성능저하가 발생할 수 있기 때문에 DF700에서 는 이를 64KB로 고정함 R/W시 발생할 수 있는 ‘Write Penalty’를 최대한 막기 위해 Cache Memory가 사용됨 ·Write Penalty RAID5는 3에서 16개 까지의 HDD로 구성(2D+1P에서 15D+1P). RAID6는 4에서 30개 까지의 HDD로 구성(2D+2P에서 28D+2P). Parity Group내에 Write I/O가 발생하면 그에 대응되는 Parity Data가 발생됨. Parity Data는 아래 공식에 의해 계산됨. RAID5 : [New Parity]=([Data before update] EOR [Data after update]) EOR [Parity before update] RAID6 : [New P parity]=([Data before update] EOR [Data after update]) EOR [P parity before update] [New Q parity]=[Coefficient parity] AND ([Data before update] EOR [Data after update]) EOR [Q parity before update] Write Penalty

  5. 1.Theory 1.2 RAID Level - RKM+RKAJ, RKS+RKAJ : RAID0(2D에서 16D), RAID1, RAID5(2D+1P에서 15D+1P), RAID6(2D+2P에서 28D+2P), RAID1+0(2D+2D에서 8D+8D) - RKM+RKAJAT, RKS+RKAJAT : RAID1, RAID5(2D+1P에서 15D+1P), RAID6(2D+2P에서 28D+2P), RAID1+0(2D+2D에서 8D+8D) - RKXS+RKAJAT : RAID1, RAID5(2D+1P에서 15D+1P), RAID6(2D+2P에서 28D+2P), RAID1+0(2D+2D에서 8D+8D)

  6. 1.Theory 1.2 Outline of Functions - DF700 구성

  7. 1.Theory 1.2 Outline of Functions

  8. 1.Theory 1.3 System Configuration of the Rackmount Model

  9. 1.Theory 1.3 System Configuration of the Rackmount Model

  10. 1.Theory 1.3 System Configuration of the Rackmount Model

  11. 1.Theory 1.3 System Configuration of the Rackmount Model

  12. 1.Theory 1.4 Configuration of Internal Data System

  13. 1.Theory 1.4 Configuration of Internal Data System

  14. 1.Theory 1.4 Configuration of Internal Data System

  15. 1.Theory 1.4 Configuration of Internal Data System

  16. 1.Theory 1.4 Configuration of Internal Data System

  17. 1.Theory 1.5 Block Diagram of Built-in Software Configuration

  18. 1.Theory 1.5 Block Diagram of Built-in Software Configuration 1. Microprograms 2. Flashprograms : Power ON 이후, Subsystem 기동에 필요한 Program (1) Fixed Part Flash Program (2) Main Part Flash Program 3. ENC/SENC Fimrware : Web 또는 SNM(Storage Navigator Modular)에서 확인 가능 (1) ENC Firmware : RKAJ를 Control (2) SENC Firmware : S-ATA에서 FC로 변환 시켜줌, RKAJAT를 Control 4. Disk Firmware : Simple Trace로부터 Disk Firmware 정보를 확인 5. Parameter Information (1) System Parameter - Main Switch ON 이후 READY LED가 ON되기 까지 필요함 - Flash Memory에 저장되며 Parameter 변경시 자동으로 Drive로 Backup 됨

  19. 1.Theory 1.5 Block Diagram of Built-in Software Configuration (2) Configuration Information - RAID/LU와 관련된 정보 - Main Switch가 꺼질 때 Drive로 내려지며, 켜질 때 RAM으로 올려짐 - 변경시 자동으로 Drive상의 정보도 변경됨 (3) SNMP Information Storage for Parameter

  20. 1.Theory 1.6 Basic Specification of the Subsystem 1. Floor (RKM+H1J) Model/Floor (RKM+RKAJ+H2J) Model 2. Floor (RKS+H1J) Model/Floor (RKS+RKAJ+H2J) Model 3. Floor (RKXS+H1J) Model/Floor (RKXS+RKAJAT+H2J) Model 4. Rackmount (RKM+RKAJ/RKAJAT) Model 5. Rackmount (RKS+RKAJ/RKAJAT) Model 6. Rackmount (RKXS+RKAJAT) Model 유첨파일(Basic Spec.ppt) 참조

  21. 1.Theory 1.7 Theory of Operation 1. IMPL Sequence Power ON Procedures 1. Main SW와 AC BOX SW가 OFF 된 것을 확인 2. Battery SW를 ON (RKXS에는 Battery SW가 없으므로 이 과정이 불필요) 3. AC BOX SW를 ON 4. Main SW를 ON 5. 약 4분 후 READY LED(Green)의 점등을 확인 (간혹 READY LED가 빠른 속도를 깜빡일 때가 있음. 이것은 ENC/SENC Firmware가 다운로드 되고 있는 과정임) 주의 : Main SW ON 이후에도 Controller의 EALM LED (Red)는 점등되어 있음. 만약 READY LED가 점등된 후에 EALM LED가 꺼진다면 이는 전혀 문제되지 않음

  22. 1.Theory 1.7 Theory of Operation 2. Sequential Shutdown Power OFF Procedures 1. Main SW를 OFF 2. PWR LED(Green)가 꺼진 것을 확인 3. AC BOX를 OFF 4. Battery SW를 OFF (RKXS에는 Battery SW가 없으므로 이 과정이 불필요)

  23. 1.Theory 1.7 Theory of Operation 3. Cache Memory Configuration 4. Dynamic Optimization of R/W Cache Area Assignment R/W Cache Area는 서로 섞이지 않으며, Host로부터의 I/O 형태에 따라 유동적으로 할당됨 Note : Parity Area를 보존하기 위해 임계값 이상으로 Write Cache Area는 할당되지 않음

  24. Contents 1. Theory 2. Installation 3. System Parameter 4. Disk Recovery Guideline 5. Part Replacement 6. AMS200 to AMS500 Upgrade Procedures

  25. 2. Installation 2.1 Fibre Channel Interface 1. Restrictions on Using the Fibre Channel Insterface Qlogic HBA(X6729A, X6730A)와는 P-to-P 지원 안됨 2. Mini-HUB RKS/RKXS는 Controller내에 Mini-HUB를 갖고 있음 4. Attention of Host Directly Connection for RKS/RKXS (1) 각각의 Host Connector에 LU Mapping 설정 불가 (2) 두 Host Connector에 대한 Transfer Speed는 반드시 같아야 함 3. Connection Specification of RKS/RKXS

  26. 2. Installation 2.2 Device ID Setting 1. For RKM+RKAJ 2. For RKM+RKAJ+RKAJAT

  27. 2. Installation 2.2 Device ID Setting 3. For RKXS+RKAJAT

  28. 2. Installation 2.2 Device ID Setting 4. Position of Switch for Device ID Setting 5. Position of the Subsystem Identification Switch 이 SW는 RKAJ 에서만 사용됨. 접속될 Basic Subsystem이 RKM이면 ‘M’측으로, RKS면 ‘S’측으로 설정함

  29. 2. Installation 2.3 Port Layout of Fibre Channel 1. RKM 2. RKS/RKXS

  30. 2. Installation 2.4 Checking Methods of Device ID and ENC Cable Connection 1. SNM(Storage Navigator Modular) 실행한 후, Main Window에서 [Tool]  [ACE Tool]을 선택하면 ACE Tool이 시작되고 Subsystem 선택화면이 나옴 2. Subsystem을 선택하고 OK 버튼을 누름 3. 구성될 Subsystem을 설정함 * 상세 작업절차는 MNTE Manual ‘INST 01-0180’참조

  31. 2. Installation 2.5 Installation of Microprogram 1. Outline of Procedure for Installation (1) WEB 또는 SNM을 이용하여 설치 (2) Service PC에 반드시 JRE 1.3.1 03 설치돼야 함 (3) WEB 사용시 [User Name], [Password] 요구시 [User Name] : maintenance [Password] : hosyu9500 2. Preparation for Installation of Microprogram (1) Outline - JRE 1.3.1 03 설치 - Security Policy File 설치 - Service PC로 Microprogram 파일 복사 (2) Service PC 설치시 제한사항 - Windows 로그인 시 User ID와 Maintenance 할 때의 User ID는 같아야 함 - Windows 로그인 시 User ID는 반드시 영문자 또는 숫자여야 함 - OS의 Drive는 ‘C:’이어야 함 (3) (2)의 사항이 갖추어지지 않을 시, Microprogram 설치 동안 Java Error Message가 발생할 수 있음 3. Procedure for settng up the service PC (1) Microprogram CD를 실행 (2) CDROM:\Micro_setup\Setup.exe 실행 (3) [Next]를 실행하면 JRE 1.3.1 03 설치화면 나옴 JRE 1.3.1 03이 설치되어 있다면 (4)에서 (8)까지 는 생략됨 (4) JAVA 1.3.1 03 설치시작 확인 화면

  32. 2. Installation 2.5 Installation of Microprogram (5) License 동의 화면. [YES] (7) JAVA Default Brower 설정 화면. 선택 후 [NEXT]. (6) JRE 1.3.1 03 설치 디렉토리 화면. [NEXT] (8) JRE 1.3.1 03 설치 진행 화면

  33. 2. Installation 2.5 Installation of Microprogram (9) JRE 1.3.1 03 설치 완료후에 Security Policy File을 설정함. 만약 현재 User의 홈디렉토리에 이 파일 (.java.policy)이 존재한다면 Overwrite 확인창 나옴. [YES] (10) Microprogram이 PC에 복사됨. 복사 후 아래와 같은 디렉토리가 생성됨  AMS500용  AMS200용  WMS용  ENC/SENC용 * Microprogram이 사용자에 의해 임의의 디렉토리에 설치하면 Microprogram 설치를 할 수 없음 4. Check Point Before Installation (1) Microprogram이 이미 설치되어 있다면 READY LED가 점등됨. 만약 READY LED가 빠르게 깜빡 이면 어떤 Update 작업을 하지 말고 점등될 때까지 기다림. 이것은 ENC/SENC Firmware가 다운로드중 에 있다는 의미. (2) WARNING LED가 점등되어 있을 때 Micro 설치가 안됨. (3) System Copy 중일때에 Update 안됨. 완료 후 Update 수행

  34. 2. Installation 2.5 Installation of Microprogram 5. Procedure for New Installation (1) Service PC와 Subsystem을 Cross Cable로 연결 (2) WEB의 Maintenance Mode 접속 (3) 좌측 ‘Microprogram’실행 (4) “Initial Setup”선택 (5) Microprogram Path 지정

  35. 2. Installation 2.5 Installation of Microprogram (6) “Install”선택 (8) 설치 완료 확인 창. [OK] (9) “To Maintenance Mode Top”선택하여 메일 화면 으로 이동 (7) 확인요청 창이 나오면 [OK]를 선택. 설치 실행됨

  36. 2. Installation 2.5 Installation of Microprogram (10) “Go to Normal Mode”선택하여 Normal Mode로 변경 (13) 약 4분 후에 READY LED가 점등됨. 만약 점등 되지 않으면 설치 실패한 것임. 다시 설치시도. (11) “Go to Normal Mode”선택 후 아래 창이 나옴. (12) [OK]를 선택하여 Subsystem Rebooting

  37. 2. Installation 2.5 Installation of Microprogram 6. Procedure for Updating Installation * READY LED가 빠르게 깜빡일 때는 Update설치를 하지 마십시오. * Microprogram Update 작업은 기존 DF600 이하와 동일함. 7. Procedure for the Version Downgrade * READY LED가 빠르게 깜빡일 때는 이 작업을 실행 하지 마십시오. * Version Downgrade시 제약 사항 및 처리 방법 * Version Downgrade 방법은 아래 [Revision Check]를 [NO]로 선택하는 것을 제외하고는 Upgrade 방법과 모두 동일함.

  38. 2. Installation 2.6 Setting S/N of Subsystem 1. WEB Maintenance Mode 접속 2. http://localhost/equip_set 접속 4. 입력된 정보 확인 후 [Save] 클릭 3. S/N 입력 후 [Set] 클릭

  39. 2. Installation 2.6 Setting S/N of Subsystem 5. http://localhost 로 이동 6. [Go to Normal Mode] 선택하여 Normal Mode로 변경 * Subsystem에 따른 Serial Number XXXXX : Subsystem 뒷면에 Stamp 로 찍인 다섯자리 숫자

  40. Contents 1. Theory 2. Installation 3. System Parameter 4. Disk Recovery Guideline 5. Part Replacement 6. AMS200 to AMS500 Upgrade Procedures

  41. 3. System Parameter 3.1 Procedure for Connecting SNM with the Subsystem 3.2 Setting Host Group 1. SNM에 등록되어 있는 Subsystem을 Open 2. [Logical Status] 탭 선택 1. Checking the LAN ennvironment setting 3. 설정하고자 하는 Port를 선택한 후 [000:G000]를 클릭하면 [Options]와 [Logical Unit]이 나옴. 2. Connecting the LAN cross cable 3. Regisgtering the newly introduced DF in SNM (1) SNM 실행 (2) SNM을 Maintenance Mode로 변경 (3) Subsystem 등록

  42. 3. System Parameter 3.2 Setting Host Group 4. [Options] 우측 클릭 후 환경에 맞게 ‘Simple Setting’ 과 ‘Detail Setting’을 설정함 * Additional Parameters Simple Setting Detail Setting

  43. 3. System Parameter 3.3 Setting LU Mapping 1. [Access Mode] 더블클릭  [Mapping Mode] 클릭  [Mode]메뉴에서 [Disable]클릭  창 우측 하단의 [Modify] 버튼이 활성화 됨  [Modify] 클릭 3. [Logical Unit] 우측클릭  [Modify Mapping] 선택 4. 버튼을 이용하여 Mapping 2. [Enable] 선택 후 [OK] 선택

  44. 3. System Parameter 3.4 Setting the RAID/LU/Spare Disk 1. RAID Group Setting (1) 좌측 [RAID Groups] 우측 클릭  [Create New RAID Group] 선택, 또는 선택 (3) (2)에서 [Manual Selection] 선택 후 [Select] 버튼 클릭하면 아래 그림 나옴 (2) [RAID Level], [Drive Configuration] 정보 선택 (4) 원하는 Drivce를 선택 후 버튼을 이용하여 RAID Group 생성

  45. 3. System Parameter 3.4 Setting the RAID/LU/Spare Disk 2. LU Setting (1) LU를 생성하고자 할 RAID Group을 선택  [Setting]  [Logical Unit]  [Create] 선택 또는 선택 (2) LU Size, Default Controller 등을 입력

  46. 3. System Parameter 3.4 Setting the RAID/LU/Spare Disk (3) LU 생성 개수 - RKS/RKXS : 512개, RKM : 2,048개 (4) Number of Block(s) and Capacity per Drive * LU가 어떤 RAID Group에 속해 있든지 또는 LU의 위치가 어디이든지 간에 상관없이 원하는 LU의 삭제 가능 4. Formatting LU (1) DF700 Format Mode는 Online Background Mode (2) Format 중에도 Host에서 LU 사용 가능 (3) 최대 512개의 LU 지정가능 하며 Format은 CTL당 6개까지 가능 (4) Format 동안 SNM을 이용한 다른 작업 가능 (5) Format 중 SNM 종료되어도 Format은 계속 수행됨 (6) Format 중 SNM 종료되어도 재접속하면 Format 진행 상황 확인할 수 있음 (7) Format 중 제약 사항 3. Deleting LU (1) 지우고자 하는 LU를 선택(다중선택:CTL키 사용) 후 [Delete] 실행

  47. 3. System Parameter 3.4 Setting the RAID/LU/Spare Disk (8) Standard Time Required for an LU Formatting * 위 시간은 I/O가 없을 경우의 시간임. I/O 발생시 Format 시간은 더 길어질 수 있음 * 위 시간은 LU 하나씩 하나씩 Format 했을 경우의 시간임. Multi LU Format 일 경우 Format 시간은 줄어들 수 있음 4. Setting of Spare Disk (1) [Spare Drives] 우측 클릭  [Set] 클릭

  48. 3. System Parameter 3.4 Setting the RAID/LU/Spare Disk (2) 원하는 Drive를 선택 후 버튼을 이용해 설정 1. Setting Boot Options - Subsystem Rebooting 필요 - READY LED 빠르게 깜빡일 경우에는 변경 금지 3.5 Setting Configuration Information [Tools] 선택  [Configuration Settings] 선택 하거나 를 선택하여 실행

  49. 3. System Parameter 3.5 Setting Configuration Information - Boot Option Parameter

  50. 3. System Parameter 3.4 Setting Configuration Information 2. Setting System Parameter - System Parameter

More Related