NCSX SXR diagnostic array. ProE model: stb-sxr_array-full.asm. T. Brown. July 25, 2005. SXR array space envelope located 0.2” off VV inner shell surface in a single plane. SXR array size and location off the inner surface of the VV spacer. Dimensions in inches.

Download Presentation

NCSX SXR diagnostic array

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Ncsx sxr diagnostic array

NCSX SXR diagnostic array

ProE model: stb-sxr_array-full.asm

T. Brown

July 25, 2005


Ncsx sxr diagnostic array

SXR array space envelope located 0.2” off VV inner shell surface in a single plane.

SXR array size and location off the inner surface of the VV spacer

Dimensions in inches


Ncsx sxr diagnostic array

SXR array units are equally spaced within the VV spool.


Ncsx sxr diagnostic array

FW envelope

Section view through VV spool piece

SXR envelope height - 6 cm (2.4”)

There is insufficient space for the SXR unit if they were located on the inside surface of the spool.


Ncsx sxr diagnostic array

VV spool modified with discrete vacuum cans used to contain the SXR diagnostic sensor

2 7/8 OD Vacuum can

.25” gap

2.4”


Ncsx sxr diagnostic array

Spool end cut

Spool midplane cut

Sufficient space can be obtained if the SXR unit is located in a recessed vacuum.


Ncsx sxr diagnostic array

Of the 16 evenly spaced SXR arrays on the spool section curve, two near the horizontal port would cause final machine assembly problems. Greater spacing in the area of the port is needed.