HP POD 数据中心新思维. 蔡建华 Product Manager , ESS , TSG CHP. Agenda. 数据中心现状及应对措施 HP POD 产品介绍 概貌 特性 工厂服务 HP POD 实用价值 优势 应用 TCO 比较. 数据中心现状及应对措施. 12 March 2014. 功率 (交换机装置、 UPS 、备用电池等) 散热 (冷却机、 CRAC 等). PUE = DC 设备总负载 / IT 设备负载. IT 负荷. 负荷不断提高 网格的需求. IT 负荷 服务器、存储、通信等设备的需求. 散热 负荷. 33%.

vivian
Download Presentation

HP POD 数据中心新思维

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HP POD数据中心新思维 蔡建华 Product Manager , ESS , TSG CHP

  2. Agenda • 数据中心现状及应对措施 • HP POD产品介绍 • 概貌 • 特性 • 工厂服务 • HPPOD实用价值 • 优势 • 应用 • TCO比较

  3. 数据中心现状及应对措施 12 March 2014

  4. 功率(交换机装置、UPS、备用电池等) 散热(冷却机、CRAC等) PUE=DC设备总负载/IT设备负载 IT负荷 负荷不断提高 网格的需求 IT负荷 服务器、存储、通信等设备的需求 散热负荷 33% 63% UPS功率4% 相关术语PUE/DCiE与功率密度 • PUE用来衡量数据中心效率 – 2006年4月 • PUE已被以下两个机构所采用: • ASHRAE (惠普是该机构的创始人) • 绿色网格联盟(惠普是BoD和Metrics Work Group Chair的成员) 85%的数据中心没有得到充分利用 PUE是一个比率,通常介于1.6~2之间, 越接近1表明能效水平越好 DCiE = IT设备负载÷DC设备总负载×100% DCiE是一个百分比值(%),数值越大越好。 • 功率密度:数据中心每平方英尺瓦数/数据中心IT设备数

  5. 数据中心分级标准(Tier Level) ● 一级:单路径的电源和散热分配,无冗余组件,99.671%的可用性。 ● 二级:单路径的电源和散热分配,冗余组件,99.741%的可用性。 ● 三级:多个电源和散热分配路径,只有单路工作,冗余组件,可同时维护,99.982%的可用性。 ● 四级:多个工作状态电源和散热分配路径,组件冗余,容错,99.995%的可用性。 Source: Tier Classifications Define Site Infrastructure Performance, W. Pitt Turner, The Uptime Institute, 2008

  6. 处于十字路口的数据中心 数据中心的电力消耗在过去10年增长了5倍 一台1U服务器的使用成本高达采购成本的2倍,并且还在继续增加 能源价格飙升导致更加困难的局面 用于空调冷却的的电力等于或超过了计算用的电力 不断扩大的IT需求和能源效率之间的尖锐矛盾 Source:Belady, C., “In the Data Center, Power and Cooling Costs More than IT Equipment it Supports”, Electronics Cooling Magazine (Feb 2007) IT & cooling power & electricity cost of $0.1/kW-hr 6 ISS-1 – HP Restricted

  7. 不断增长的计算密度源于应用的快速增长

  8. 当前的数据中心环境 • 数据中心挑战 • 电源、散热和空间容量限制了IT的发展 • 扩展受制于数据中心构建时间 • 需要更高的能效 • 能耗成本不断增加 • 传统的数据中心不能实现密度最大化 • 资本压力不断上升 • 预计容量将不断增加 • 按需购买有助于延缓资本支出

  9. 9.43 14.82 19.75 16.02 39.99 当前数据中心状态 • Gartner – 超过70%的全球1000企业都将在今后5年内对数据中心的设备进行更新与扩展 • 美国拥有最多的大型数据中心 • IDC 评估了 7,000 个企业数据中心 (25k sq. ft.) • 大部分都在刀片出现之前设计(7年以上) • 按 35 - 70 W/sqft 设计(当前需求150-200 W/sqft - Gartner) • 数据中心挑战(IDC) • 电源/散热 • 可用性/冗余/灾备 • 空间受限 Tier Level (Weighted Average) Source: Key Findings from Datacenter Dynamics shows in 8 cities in 2008 Power Usage in the Datacenter Tier 1 Unsure Tier 2 Tier 4 Tier 3 Source: Marsan, Carolyn Duffy, Data center power: the cost reality, NetworkWorld, Feb. 18th, 2008

  10. 天花板高压回风 ceiling return air plenum 精确设置回风口 critically placed return grilles 机架挡风条 rack blanking panels 静态智能散热Static Smart Cooling • 优化计算资源的布局 • 优化冷却资源的配置 • 对制冷基础设施的实时控制 • 机架制冷控制 Adds another 15% improvement in efficiency

  11. DSC动态智能散热: 适应性基础设施的关键支持因素 • 数据中心电源和散热管理解决方案,以惠普实验室软件作为主要的IP • 所有空气调节系统或机房均实行统一的管理(包括数据中心和通信设备) • 使用SIM和OV,实现可改造的绿色数据中心 • 广泛的机架级热感应网格,带有机房级分区能力 • 动态管理CRAC,大大节约能源 传感器和控制网络 VFD风扇转速控制器 可调整功率的CRAC设备 机架进气口热量传感器 水温控制阀 • DSC管理服务器 • 传感器网络/数据仓库 • 系统状态评估 • 散热系统控制 冷却水供应循环

  12. HP Optics 3. Data Center Power 2. Rack Level Power 4. CRAH Power 5. Air Pressure 1. Distributed Temp • 深入的实时环境度量 • 成本经济的部署、升级与维护 • 全面性 • 厂商无关 • 能够及时反映数据中心变化 • 图形化实时可视性与历史度量 • 持续对数据中心处于稳定状态或对变动状态提供反馈 • 产品适应于整个数据中心生命周期 • 消除数据中心转向高密度设备时的风险 12 March 2014

  13. 惠普模块化冷却系统(水冷机柜)高密度计算与数据中心热点的理想解决方案惠普模块化冷却系统(水冷机柜)高密度计算与数据中心热点的理想解决方案 • 惠普认证并集成 • 模块化 & 冗余设计 • 单个机柜中高达 35kW 冷却能力 • 容纳达 900Kg IT设备 • 气流一致服务器前端穿透 • 防水安全设施 • 服务器空气温度可调 • 不会增加数据中心热负载 • 与HP-SIM集成管理

  14. c-Class Blades 3 10U c-Class Blade chassis per rack Up to 17.5kW per side Factory Express or VAR integration MCS G2 超高密度能力 6kW 6kW 6kW 6kW 5.5kW 5.5kW

  15. 惠普在数据中心的持续投资 Over 1000 patents , 300 dedicated engineers on datacenter power and cooling 2001 Consolidation Machines for better utilization and management 1996 Computational Fluid Dynamics (CFD) applied to datacenters 2008 EYP MCF Acquisition & HP POD Data Center in Container for efficiency 2004 Introduction of server power management technologies 2006 BladeSystemc-Class introduces HP Thermal Logic for improved efficiency 2007 Dynamic Smart Cooling (DSC) 1998-2004 Fundamental research in Dynamic Smart Cooling 2009 Optics with real-time graphics 1999-2000 First datacenter test prototype in partnership with Ericsson/Liebert 500 W/sq ft 2006 Modular Cooling System (MCS) Liquid cooled Rack 15

  16. HP POD产品介绍 12 March 2014

  17. 集装箱式数据中心考量指标 Compute 密度 Storage Power Provisioning Efficiency 可靠性 成本 ROI Capex + Opex x time Capex + Opex x time AFR UIPS Remote visibility Time to deploy 部署 管控 Geographic reach Remote control Are these the right measures? How do you prioritize them? HP Confidential

  18. HP POD 应对数据中心挑战 相对传统土建式数据 中心节省高达20% 更低的建设与获取成本 降低建设与部署时间 美国6周、 全球12周交货 减少运维花费 能耗高效: PUE 值<1.25 更高的功率密度 高达27kW/rack 或3,520 节点 基于可复制的模块化设计扩展 按成长付费

  19. HPPOD

  20. HP POD主要特性 出色的工业标准灵活性22或 x 50U、19英寸全深工业标准机架,支持惠普、戴尔、IBM、Sun、Cisco等厂商产品 一流的密度支持3,520个计算节点、12,000块LFF硬盘,或这些组件的任意组合 内置的冗余性电源和散热冗余,包括输送到机架的独立电源 10-12周运达,部署范围覆盖全球发运前经过预先集成、配置和测试;从订购之日起6周内发运 能源效率PUE比率低于1.25(1.07,不包括水冷) 基础设施服务组合 包括技术与设施专业知识在内的完整生命周期支持服务 从站点准备服务到日常POD维护和支持 8 2009年5月13日星期三

  21. 20’ HP POD • 350 – 400kW • 27kW每机架 • 11 个 50U 机架 • (550U IT计算空间) • 高达1,760 节点 • 多至6,160 HDD • 冷却水散热 • 防火与烟雾警报 • 使用工业标准机架,支持第三方IT 设备 HP Confidential

  22. 40’ HP POD/12.2m • 600kW+ • 27 kW 每机架 • 22 个 50U 机架 • (1100U IT计算空间) • 高达3,520 节点 • 多至12,320 HDD • 冷却水散热 • 防火与烟雾警报 • 使用工业标准机架,支持第三方IT 设备

  23. 电源模块 • 模块化,便携式持续供电系统基于Active Power高效率和高弹性的架构,可提供快速部署能力。 • 20’ 集装箱 • UPS • 电池组 • 转换模块 • 热交换器 节省25%的投资和降低至60%的TCO!

  24. 空载POD内部视图 冷过道外部的设施管理 HP MCS提供高效的变速鼓风机 HP MCS提供高效的换热器(HEX) 36英寸冷通道,可在超过90F的温度中运行 4x or 6x 225A 三相电源 电源, FC, BMS 接入线路 标准50U机架 火警侦测与报警线路 可通过集装箱门从后部访问热过道 冷通道门

  25. 40英尺集装箱的布局 三相电源分线箱(3个) 支持3条400A电源总线线路。 支持12组耐用换热器。 进入后服务区的4组双开门。 火警拉线开关 鼓风机风扇 BMS(楼宇管理系统)面板 烟箱 紧急断电(EPO)面板 火警面板 业务流程管理(BPMS)面板 加湿器 机房面板 风扇控制面板 进入冷过道的人行门 拉箱 火警拉线开关

  26. 场地要求 • 能够承受POD重量的平坦地面 • 推荐POD 安装于架高102mm 厚的混凝土面上. • 地面水平度误差范围 +/- 0.5度 • 公用系统 • 冷却水 • 增湿器使用工业用水 • 排水设备 • 电源 • 到中央设施的连接 • 楼宇管理系统(BMS) • 安全系统 • 电源插座 • 站点网络 • 环境因素 • 考虑安装雨篷或其它小型物理结构以提高集装箱的耐用性和安全性 • 避雷功能 • 接地 • 工作温度 • -15 至54 ° C. (非工作温度:2 至 54°C)

  27. 数据中心集成和规划服务 量身定制的POD工厂预装特快服务 现场实施服务 日常维护与支持服务 HP POD基础设施服务面向POD解决方案整个生命周期的服务

  28. 定制机架附带工厂预装特快服务

  29. 作为行业领先厂商,惠普可为您提供完整的集装箱解决方案作为行业领先厂商,惠普可为您提供完整的集装箱解决方案 技术 惠普集装箱和IT产品组合 + 设计 EYP定制服务 + 制造 工厂预装特快服务 + 部署 惠普服务 = 惠普数据中心集装箱解决方案

  30. HP POD实用价值 12 March 2014

  31. PUE低于1.25 PUE约1.7 1800瓦以上/平方英尺 150-200瓦/平方英尺 在六周内发运 大约需要两年的时间进行设计和构建 HP POD是对传统数据中心的完善 能源效率 地域灵活性 最大冗余 最高安全性 IT灵活性 部署速度 功率密度 集装箱 传统数据中心

  32. POD 客户使用方式 加快部署速度 扩容 – 40% • Hetero IT flexibility • Energy efficiency • WW integration & support • Financial Terms • Redundancy 灾备 10% • Hetero flexibility • WW deployment Technology Flexibility 过渡 10% 军队 • Hetero flexibility • Financial terms • Mobility/remote • Hardened shell • Custom IT – 10% 扩建 – 30% • Homogeneous IT • Max. density • Max. energy efficiency Standard 通讯 Redundant • Mobility/remote • Hardened shell Custom Redundancy HP Confidential

  33. 客户使用案例 • 云服务 • 软件公司 • 扩展性 • 快速成长 • 能源效率 • 私有云 • 军队 • 扩展性 • 复制性 • 多场地使用 高性能计算 • 欧洲制造企业 • 快速部署 • 极高IT密度 • 能源效率 数据中心扩容 • 电信企业 • 快速增长 • 支持刀片服务器

  34. 总体拥有成本对比POD与新建数据中心 • POD优势 • 占地空间节省约6倍 • 散热功耗减少60%以上 • 总功耗降低25%以上 • 资本支出减少35%以上 • 年运营支出减少60%以上