An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DETECTION AND ISOLATION OF A SENSOR DRIFT FAULT Yilun Zhou Prof. Thomas Parisini Imperial College London UKACC PhD Presentation Showcase

  2. Introduction • Background • Complex control systems and demand for fault tolerance • Process fault and sensor fault in nonlinear systems • Model-based fault detection and isolation schemes (FDI) • Time evolution of faults: abrupt and incipient faults • Objectives • A class of nonlinear systems with sensor drift faults • Adaptive and less conservative threshold UKACC PhD Presentation Showcase

  3. Problem Formulation and Methodology • A class of nonlinear MIMO system with sensor drift faults • Detection Estimators and Isolation Estimators • Residual and Threshold >> crossing s Drift faults, s Isolators. d Any crossing excludes faulty assumption. UKACC PhD Presentation Showcase

  4. Simulation Result • Detection At t = 13s, a fault occurs. Then the fault is detected at t = 16.64s UKACC PhD Presentation Showcase

  5. Simulation Result • Isolation There is a crossing in isolator 2. The possibility of fault occurrence in Sensor 2 is excluded. Drift fault occurred in Sensor 3 UKACC PhD Presentation Showcase

  6. Conclusion and Future work • Conclusion: • Adaptive threshold increases robustness and stability • Fault compensation in isolators improves performance • Future Work: • Design a FDI approach for a hybrid sensor fault • Design a distributed fault diagnosis approach • Design a benchmark test using the FDI scheme UKACC PhD Presentation Showcase