Power Electronics and Motor Drives Laboratory . Contact Info: Fang Z. Peng, [email protected], 517-432-3331. Objective : To develop an efficient and low cost adjustable speed drive while minimizing switching frequency and input current harmonic distortion using the PEBB concept.

Download Presentation

1 MVA, 6,000 V Cascaded Multilevel Inverter/Adjustable Speed Drive

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


1 mva 6 000 v cascaded multilevel inverter adjustable speed drive

Power Electronics and Motor Drives Laboratory

Contact Info: Fang Z. Peng, [email protected], 517-432-3331

Objective: To develop an efficient and low cost adjustable speed drive while minimizing switching frequency and input current harmonic distortion using the PEBB concept.

83 kVA Multilevel Inverter Building Block

1 MVA, 6,000 V Cascaded Multilevel Inverter/Adjustable Speed Drive

  • Features

  • Uses 12 identical multilevel inverter building blocks in cascade to create a 3-phase, 17 level topology;

  • Able to use 1200V IGBTs, while total output voltage is 6,000 V ac;

  • Utilizes a unique configuration to minimize harmonic line current;

  • The 17-level topology allows for low harmonic content at the output at very low switching frequencies;

  • Low dv/dt reduces motor insulation stress

1 MVA, 6000 V System Operation