An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BOD, COD and you use a lab sample? 2nd Water/Wastewater and Automatic Controls Conference Orlando August 9, 2007

  2. Presenter Robert Lagrange Co author Business Manager Tracy Doane-Weideman Water and Wastewater Product Manager Analysis Endress+Hauser Inc.

  3. Schedule • Organic Load • Importance for plant operation • Laboratory Measurements • BOD 5 • COD • On-Line Measurements • BOD • COD • Questions

  4. Is it important to know the organic load ? • A change of organic load requires process adjustments • Controlling the Dissolved Oxygen concentration in the aeration tank is a typical way to compensate for this • But !!!! It could be too late if the plant capacity is limited It is better to know ahead of time, much more if there is a possibility to equalize the load or limit the intake of high load from industrial plants

  5. BOD variations at a municipal WWTP Reference: Finbarr O Riordan

  6. Measurement of Organic Load • TOC • COD • BOD “the fundamental purpose of the treatment plant is to reduce the bio-digestible organics”

  7. Issues with laboratory measurement • BOD 5 Lab • Takes 5 days • Accuracy/Repeatability

  8. Accuracy of lab measurement Reference: M. Köhne

  9. Issues with laboratory measurement • BOD 5 Lab • Takes 5 days • Accuracy/Repeatability • COD • Takes 2 hours • Maintenance of the lab instrument • Disposal of waste stream depending on method

  10. O2 Uptake mg/l Michaelis- Menten Kinetics Model 3 mg O CONTROL POINT 2 5 m g B O D / l Nutrient Concentration in mg BOD / l Michaelis- Menten Kinetic Model

  11. How does it work? • Thousands of small plastic rings within the bioreactor provide a growth surface for the biomass. • The biomass is fed a mixture of wastewater and oxygen saturated dilution water • The dilution is constantly adjusted to maintain a 3mg/l oxygen consumption • The ratio of wastewater to dilution water defines BOD based on the Michaelis- Menten Kinetic Model

  12. Construction

  13. Before Calibration After Calibration Trending & Calibration Reference: Alexander Borys

  14. Another trending example Reference: Finbarr O Riordan

  15. Reference: Finbarr O Riordan Reference: Alexander Borys Maintenance On-line BOD

  16. On-Line COD • Ozone is mixed with dilution water. The resulting concentration is measured by the first ozone sensor. • In the reaction chamber the waste water is oxidized by the ozonized dilution water • The ozone concentration in the reactor is measured by the second ozone sensor. • The consumption of Ozone is proportional to the COD

  17. Use of BOD for monitoring and control

  18. Use of BOD for balancing load

  19. Thank you ! Questions ?