14 May 2015
This presentation is the property of its rightful owner.
Sponsored Links
1 / 7

Ethernet Temperature & Humidity Data Logger for remote monitoring PowerPoint PPT Presentation


Measure and Record 2 Temperature Readings Using External Sensors-40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy Configure, Setup and Manage Data Loggers over an Internet Connection and BrowserFree WebStorage Service, WebViewer and Current Readings Monitor Software IncludedPhone call, Email & SMS alert system (optional) Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile MemoryUser-Configurable Sampling Rate: 1 Second to 1 HourEmail Alarm Notifications and Optional External Contact Terminal for Electromagnetic ContactorAC Powered with Battery Backup for Power Failures and Emergency Use Only Automatic Sending of Measured Readings via FTP or E-mail

Download Presentation

Ethernet Temperature & Humidity Data Logger for remote monit...

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

Ethernet Temperature & Humidity Data Logger for remote monitoring

Features

>> Measure and Record 2 Temperature Readings Using External Sensors

>> -40°C to 110°C Temperature Recording Range with ±0.3°C Temperature Accuracy

>> Configure, Setup and Manage Data Loggers over an Internet Connection and Browser

>> Free WebStorage Service, WebViewer and Current Readings Monitor Software Included

>>Phone call, Email & SMS alert system (optional)

>> Stores up to 8,000 Sets of Recorded Readings onto Internal Non-Volatile Memory

>> User-Configurable Sampling Rate: 1 Second to 1 Hour

>> Email Alarm Notifications and Optional External Contact Terminal for Electromagnetic Contactor

>> AC Powered with Battery Backup for Power Failures and Emergency Use Only

>> Automatic Sending of Measured Readings via FTP or E-mail

Specifications

TR-701NW /

701AW

TR-702NW / 702AW

TR-702NW-H / 702AW-H

TR-0106

THA-3151

HHA-3151(High-Precision Type)

Temperature/Humidity

Sensor (External)

Polymer

Resistance

Platinum

Resistance

Electrostatic

Capacitance

Thermistor

Thermistor

Temperature

2ch

Temperature

1ch

Humidity

1ch

Temperature

1ch

Measurement

Channels

Humidity 1ch

°C, °F

°C, °F

%RH

°C, °F

%RH

Measurement Units

-40 to

110°C(Supplied

Sensor)

-60 to

155°C(Optional

Sensor:

Fluoropolymer

Coated Type)

10 to

95%RH

0 to 55°C

-30 to 80°C

0 to 99%RH

Measurement Range

±2.5%RH [at 25°C, 10

to 85%RH]

±4.0%RH [at 25°C, 0

to 10%RH or 85 to

99%RH]

At temperatures other

than 25°C and ≥ 0°C,

add ±0.1%RH per

degree of difference

from 25.

Humidity Hysteresis:

±1.5%RH or lower *1

Avg. ±0.3°C [-

20 to 80°C]

Avg. ±0.5°C [-

40 to -20 / 80 to

110°C]

±0.3°C [0 to

50°C]

±0.5°C [at all

other

temperatures]

±5%RH [at

25°C,

50%RH]

±0.5°C

Accuracy

Measurement

Resolution

0.1°C

0.1°C

1%RH

0.1°C

0.1%RH

Thermal Time

Constant:

Approx. 75sec.

Response

Time (90%):

Approx. 7min.

Response Time (90%):

Approx. 7min.

Response Time

(90%): Approx. 20sec.

Responsiveness

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

Response Time

(90%): Approx.

190sec.

8,000 data sets (One data set consists of readings for all channels in that type of

unit.)

Logging Capacity

Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60

min.

Recording Interval

Endless (Overwrite oldest data when capacity is full)

Recording Mode

Measurements (alternating display), Power Warning Mark, etc.

LCD Display Items

TR-701NW / 702NW: Wired LAN

RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X

TR-701AW / 702AW: Wireless LAN

Internal wireless LAN antenna IEEE 802.11b/g

WEP(64bit/128bit) / WPA-TKIP/WPA2-AES

USB Communication (For Setup)

Communication

Interfaces

<Output Terminal: Photo Mos Relay Output>

Voltage when OFF: AC/DC less than 50V

Current when ON: less than 0.1A

Resistance when ON: about 35Ω

External Alarm

Terminal

HTTP, SMTP (POP before SMTP, SMTP-AUTH <LOGIN>), FTP, SNTP, DHCP,

DNS

Communications

Protocol

Main Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type

Lithium Battery (CR-2032) *2

Power

Approx. 3 months (backup battery CR-2032 only without AC adaptor)

Data Backup *3

H 55 mm x W 78 mm x D 37 mm

Dimensions

TR-701NW / 702NW / 702NW-H : approx. 82 g

TR-701AW / 702AW / 702AW-H : approx. 80 g

(including battery, excluding sensor)

Weight

Temperature: -10 to 60°C

Humidity: 90 %RH or less (no condensation)

Operating

Environment

High Precision

Temperature/Humidity

Sensor (HHA-3151) x

1

Temperature Sensor (TR-

0106) x 2

Temperature/Humidity

Sensor (THA-3151) x 1

Accessories

USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW /

702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery

(CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1

<Desktop Browser>

Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later),

Safari (6.0 or later)

<Mobile Browser>

Safari (iOS), Chrome (iOS, Android), Firefox (Android)

Supported Browsers

*1: When used in environments where temperature and humidity are over the values of 50°C 75%, 60°C

50%, 70°C 35%, and 80°C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under

certain circumstances, it may take some time to return to normal measurement capability.

*2: The supplied lithium battery is for data backup during power failure and for emergency use only. Note

that network communication cannot occur when using only the battery.

*3: Battery life varies depending upon the ambient temperature and the battery performance. All estimates

are based on operations carried out with a new battery and are in no way a guarantee of actual battery

life.

Use via Network Connection

The TR-700W Series Loggers allow you to make device settings, monitor current readings, gather recorded data

and an array of other functions via LAN or Internet connection.

The USB connection also allows for settings including wired LAN and wireless LAN settings to be made directly

from a PC.

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

Various Monitoring Functions

Using "WebViewer":

The TR-700W Series WebViewer application enables the viewing of data graphs in your browser.

In the browser you can not only view graphs and current readings, but also settings information for the target TR-

700W Series device.

Using "T&D WebStorage Service":

As long as you have access to the Internet, our "T&D WebStorage Service" is available; thus bringing you

"anytime anywhere" access to your recorded data for monitoring, saving, analyzing, printing, and so on.

This service also allows for the viewing, sharing and usage of data by multiple parties across distances at the

same time, thus providing increased management efficiency.

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

Via "Current Readings Monitor":

The "Current Readings Monitor" application included in the software package allows not only for the management

of current readings, but also provides a way to manage all devices registered on the same network.

Via Mobile Device:

Both "WebViewer" and "T&D WebStorage Service" can be used with mobile devices such as smart phones and

tablets, enabling easier access to data anytime, anywhere.

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

Efficient Warning Monitoring Functions

It is possible to have warning report e-mails sent when user set conditions have been met.

Warning report mails can be sent when an upper and/or lower limits have been exceeded, when a sensor error

has occurred or when there has been a recovery from one of the set warning conditions.

Also, by connecting a warning device to the external contact output terminal, it is possible to receive notification

of a warning by buzzer, siren, lamp, or other electromagnetic contactor. It is also possible to select whether or not

to have the external warning coupled with a warning report mail.

Auto-Sending of Measurements

Using Device Settings for TR-700W Series Data Logger:

By making settings in the device it is possible to automatically have Recorded Data and/or Current Readings sent

periodically via FTP or e-mail without the need for PC.

Using the "Current Readings Monitor":

If a server is not available, it is possible to use the "Current Readings Monitor" application to have recorded data

automatically saved.

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

High-Performance User Friendly Graph Software Available

Our newly designed software "T&D Graph" gives you greater management and analyzing power for dealing with

the recorded data (TRZ format) collected from TR-700W Series loggers.

"T&D Graph" allows you to read larger numbers of recorded data files (TRZ format) into the same graph, merge

data, view and save data various ways. It can be downloaded free of charge at theT&D Website.

This versatile graph tool not only allows the user to directly access data stored in the WebStorage Service, but

the user can also specify conditions such as time period for which data to view and analyze.

It is also possible to sample and filter data, add memos and write comments directly on the graph, as well as,

save data to CSV Format for use with common spreadsheet software.

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India


Ethernet temperature humidity data logger for remote monitoring

14 May 2015

All images and data above are copyrighted to the manufacturer T&D corporation, Japan

Videos:

Functioning demo : http://bit.ly/1jZAJRe

Remote monitoring software demo : http://bit.ly/1srWvh8

Vacker LLC l PO Box 92438 l Dubai l UAE

Phone : (+971) 42 66 11 44 l Fax : (+971) 42 66 11 55

email:[email protected]

www.vackerglobal.com

Offices: UAE, USA, Kuwait, Oman & India