Pm9 pm9p and pm9c power meter
This presentation is the property of its rightful owner.
Sponsored Links
1 / 28

PM9, PM9P and PM9C Power Meter PowerPoint PPT Presentation


  • 302 Views
  • Uploaded on
  • Presentation posted in: General

PM9, PM9P and PM9C Power Meter. Power Meter PM9. 1. PowerLogic Family Applications Benefits Power Meter overview Application tips. 2. 3. 4. 5. A new Power Meter in the PowerLogic range. CM 3000 / CM 4000. PM800. PM9. PM700. PM 500. PM9 key features comparison. PM9. PM9P. PM9C.

Download Presentation

PM9, PM9P and PM9C Power Meter

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Pm9 pm9p and pm9c power meter

PM9, PM9P and PM9C Power Meter


Pm9 pm9p and pm9c power meter

Power Meter PM9

1

PowerLogic Family

Applications

Benefits

Power Meter overview

Application tips

2

3

4

5


A new power meter in the powerlogic range

A new Power Meter in thePowerLogic range...

CM 3000 / CM 4000

PM800

PM9

PM700

PM 500


Pm9 pm9p and pm9c power meter

PM9 key features comparison

PM9

PM9P

PM9C

Modbus RS485 port

Pulse output

1

Accuracy IEC62053-21(IEC 61036)

1

1

1

Timer

Power demand and Max demand

U, V, I, F, PF, Power, Energy


6 references

6 references

  • AC version220 to 240 VAC

    • PM9 with display only15 199

    • PM9P with pulse output15 197

    • PM9C with communication15 198


Pm9 pm9p and pm9c power meter

Power Meter PM9

1

PowerLogic Family

Applications

Benefits

Power Meter overview

Application tips

2

3

4

5


Pm9 pm9p and pm9c power meter

Use the Power Meter as the first step of power monitoring information to manage total costs

  • Reduce energy costs

  • Increase equipment utilization

  • Improve reliability of supply


If you can not measure it you can not manage it

If you can not measure ityou can not manage it


Pm9 applications

PM9 applications

Higher accuracy & functionality,

more I/Os...

Panel power metering

basic power metering

Sub-billing / cost allocation

allocate cost by workshop not by m2

Energy usage

consumption patterns, capacity planning

Real time monitoring

Contract optimisation

includes synchronised demand...

Power quality monitoring

THD, Harmonic analysis

Advanced quality monitoring

waveform capture, sag & swell

PM9/PM7

PM8

Circuit Monitor


Pm9 applications1

PM9 applications

Higher accuracy & functionality,

more I/Os...

Panel power metering

basic power metering

Sub-billing / cost allocation

allocate cost by workshop not by m2

Energy usage

consumption patterns, capacity planning

Real time monitoring

Contract optimisation

includes synchronised demand...

Power quality monitoring

THD, Harmonic analysis

Advanced quality monitoring

waveform capture, sag & swell

  • Local display of basic values

    • I, U and more

  • Quick check that everything is OK

    • show three information at the same time

PM9/PM7


Pm9 applications2

PM9 applications

Panel power metering

basic power metering

Sub-billing / cost allocation

allocate cost by workshop not by m2

Energy usage

consumption patterns, capacity planning

Real time monitoring

Contract optimisation

includes synchronised demand...

Power quality monitoring

THD, Harmonic analysis

Advanced quality monitoring

waveform capture, sag & swell

  • Allocate exact cost by tenant

  • Allocate cost by workshop or production line, not by m2:

    • include electricity cost in variable cost not in fixed cost

PM9/PM7


Pm9 applications3

PM9 applications

  • Save energy by knowing your consumption patterns

    • implement awareness programs, best practises, peak shaving

  • Save investment by improving capacity planning

    • identify spare capacity

  • Improve reliability

    • balance busbar loading

  • Improve system power factor

  • avoid penalties

Panel power metering

basic power metering

Sub-billing / cost allocation

allocate cost by workshop not by m2

Energy usage

consumption patterns, capacity planning

Real time monitoring

Contract optimisation

includes synchronised demand...

Power quality monitoring

THD, Harmonic analysis

Advanced quality monitoring

waveform capture, sag & swell

PM9/PM7


Pm9 applications4

PM9 applications

  • Improveefficiency with remote monitoring

    • useful information available at your desk (electrical parameters, status…)

    • early detection of problems

    • aids trouble-shooting and diagnostics

    • make decision based on real information

  • Minimise down time

    • understand rapidly what happened during crisis and find causes of problem

Panel power metering

basic power metering

Sub-billing / cost allocation

allocate cost by workshop not by m2

Energy usage

consumption patterns, capacity planning

Real time monitoring

Contract optimisation

includes synchronised demand...

Power quality monitoring

THD, Harmonic analysis

Advanced quality monitoring

waveform capture, sag & swell

PM9/PM7


Pm9 pm9p and pm9c power meter

Power Meter PM9

1

PowerLogic Family

Applications

Benefits

Power Meter overview

Application tips

2

3

4

5


Compact design

Compact Design

  • 4 modules of 18 mm only, width of 72 mm

    • Basic

    • with Modbus communication

    • or with 1 pulse output

    • saves space for other meters or for miniature circuit breakers

72 mm


Large backlit display

Large backlit display

  • Large back lit LCD display

    • Easy to read in extreme light conditions

  • View multiple values on one screen

    • View three phases at the same time

  • 2 level backlight

    • first level: permanent backlight to ease viewing at any time

    • second level: enhanced when a key is pressed


Monitor in confidence

Monitor in confidence

  • Energy class 1 according to IEC62053-21

    • monitor in confidence your electricity consumption

  • Power demand measurement and max demand recording

    • monitor power demand overshoot

  • Neutral current calculation

    • check neutral conductor is not overloaded especially because of harmonics


Pm9 pm9p and pm9c power meter

Power Meter PM9

1

PowerLogic Family

Applications

Benefits

Power Meter overview

Application tips

2

3

4

5


Functions

General

for LV system 1P+N, 3P, 3P+N 

voltage direct connection up to450VAC450VAC

Basic Instrumentation

I, U, V, F , PF  

P total and per phase  

Q total and per phase  

S total 

PF total  

active and reactive energy (2 quadrants)  

Other measurements

neutral current  

active or reactive or apparent power demand  

Max power demand  

timer  

Functions

PM9/PM9P

PM9C


Functions1

Display and I/O

Backlit LCD display with 3 lines

1 pulse output for active or reactive energy PM9P

Communication

2 wire RS485 Modbus port 

Baud rate 19 200

SELV circuit, double insulation

Power supply

AC version 220 to 240VAC ± 10% 

DC version24 to 48 VDC ± 20% 

Accuracy

I, U, V% of reading±0.5% ±0.5%

Energiesas per IEC62053-21 or IEC61036Cl1Cl1

Functions

PM9/PM9P

PM9C


Functions2

Operating temperature

-5°C to +55°C 

Operating environment

installation category up to 450 VACIIIIII

pollution degree22

Functions

PM9/PM9P

PM9C


Pm9 pm9p and pm9c power meter

Power Meter PM9

1

PowerLogic Family

Applications

Benefits

Power Meter overview

Application tips

2

3

4

5


Local panel instrumentation

Local Panel instrumentation

Local display

of all information


Remote monitoring

Remote monitoring

  • With the addition of an Ethernet Gateway, the meter can communicate via the existing network

    • Create a simple system using a PM9C, EGX400, and a PC with web browser software

      • View instantaneous readings of amps, voltage, power and energy

      • View historical values

      • No special software to install

PC with Browser

EGX400 Gateway

PM9C


Sub billing cost allocation

Sub-billing / Cost allocation

2 options

PM9C

PM9P

Pulse output

PLC

Building Mgt System

Modbus comms

Power Mgt System


Submetering cost allocation in buildings

Submetering/cost allocation in buildings

EGX 400 or

Twido PLC

used to push data on

LAN

or

Twido PLC

used as pulse

concentrators

pulse

PM9P


You may need a pm700 or pm800 for

You may need a PM700 or PM800 for...

PM800

  • Alarms with timestamping

  • Harmonic analysis

  • logging memory - 80Kb to 800Kb

  • Optional I/Os

  • Class 0.5S accuracy

PM700

  • Better and bigger display

  • THD monitoring

  • Min / Max values

  • Flush mount


Powerlogic range summary

CM 4000

PowerLogic range summary

CM4000

CM3000

CM 3000

PM800

PM 500

  • Apply to Critical Power: Utility switch, Mains, sensitive Feeders

  • Extensive Power Quality monitoring

  • EN50160 compliance checking

  • Transient Detection and flicker

  • Wave shape fault recording

  • Class 0.2S

  • Memory up to 32MB

  • Up to 25 I/O points - Variety of I/O

  • GPS time synchronization

  • HTML pages standard & custom with Ethernet option

  • Programmable functions

PM700

PM9

PM 500

  • Apply to Mains and Feeders

  • Comprehensive Power Monitoring

  • Alarms with timestamping

  • Harmonic analysis

  • Class 0.5S

  • Onboard data logging up to 800 ko

  • up to 18 I/O points

  • Apply to Feeders

  • Panel instrumentation

  • sub-metering / cost allocation

  • Power Monitoring


  • Login