1 / 8

“Galileo Galilei” (GG)

GG Phase A-2 Study funded by ASI ongoing at TAS-I (TO) with support from GG/GGG scientists GG target: test the Equivalence Principle to 10 -17 (4 orders of magnitude gain). “Galileo Galilei” (GG). GG inside Italian Vega launcher (double launch possible; Kourou launch site).

Download Presentation

“Galileo Galilei” (GG)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GG Phase A-2 Study funded by ASI ongoing at TAS-I (TO) with support from GG/GGG scientists GG target: test the Equivalence Principle to 10-17 (4 orders of magnitude gain) “Galileo Galilei” (GG) GG inside Italian Vega launcher (double launch possible; Kourou launch site) Low altitude equatorial orbit. Operation from Italian station in Malindi (Kenya) Passive stabilization by 1-axis rotation (cylinder height: 1.5 m) TAS-I has built GG Drag Free Control System + Space Experiment Simulator based on heritage as prime contractor of ESA mission GOCE - now flying and performing at 2x10-9 ms-2/Hz (from 2 mHz to 0.2 Hz) + relevant input data taken from GGG lab experiment GG Phase A-2 Study Report under completion (to include all mission costs except launch) Strategy: Exploit Italian launcher, rely on TAS-I heritage from GOCE, rely on GGG lab prototype, keep satellite cost very low….

  2. __ July 2005 __ Sept 2007 __ June July 2008 __20-21 Oct 2008 GGG prototype: results till 2008 Improvement in sensitivity Vacuum chamber (second hand..) has wrong symmetry… 10-8 m GG in space must sense about 10-12 m relative displacements at 1.75x10-4 Hz to reach target (EP test to 10-17). GGG has measured 3x10-9 m at 1.7x10-4 Hz and 6x10-9 m at diurnal frequency. With GGG coupling (not as weak as it will be in possible in absence of weight) these results correspond to: Good sensitivity at very low frequencies sun=2.5x10-7 Earth GG orbit=7.7x10-11

  3. New chamber (built) for an advanced GGG (under construction) - ASI funds Old GGG mounted in new chamber New chamber has the right symmetry and has been designed to minimize disturbances on GGG New GGG will be suspended inside chamber by cardanic joint (not rotating) to reduce low frequency terrain tilts passively, in addition to active tilt control now in use (Note: active tilt control is limited by thermal effects on tilt sensor and requires good thermal stabilization to be effective) An Experiment Simulator will be built by Thales Alenia Space-Italy for the new GGG, similarly to the Simulator built for the space experiment, to be compared with experimental measurements …

  4. Assessing the lower platform noise provided by the new chamber Time (sec)

  5. Thermal stabilization of new chamber Thermal stability is required primarily because the tilt sensor used in the control loop to reduce low frequency (diurnal) terrain tilts is affected by thermal variations The body of the chamber is stabilized by heating only (to 30 °C) FFT of temperature inside chamber at tiltmeter level: diurnal variation reduced to 0.01 °C

  6. First runs in new chamber Old chamber, thermal stabilization by heating + cooling; tilt control with online compensation for temperature effects on tilt sensor New chamber, thermal stabilization by heating only; tilt control without online compensation for temperature effects on tilt sensor Results are already comparable but runs in new chamber are still being improved

  7. Patches of charges on the surface of test masses are known to be a threat for gravity experiments. Have affected GP-B mission preventing so far the recovery of Lense-Thirring effect (GP-B masses not grounded: UV electric discharging, similar in LISA and LISA PF) Direct measurement of electric patch effects on GGG GG/GGG masses grounded; GG co-rotating makes patch effects mostly DC We have implemented a method to measure patches of charge in GGG during experiment runs: patch charges (if present) are excited to produce a differential displacement of the test cylinders at a desired frequency. The method allows us to measure Vpatch rigorously and to asses the effect on the test masses 4 cm2 Al plate used to excite patch (at about 10-2 Hz); no gold coating…. x= 0.0275 micron y = 0.006 micron Measured: Vpatch= 0.3 V In GGG, beware of patch effects between rotating and non-rotating parts, as they could produce low frequency effects….

  8. Development of a high sensitive double pendulum tiltmeter for low frequency tilt control Simple pendulum and inverted pendulum aligned, pendulum masses connected by thin cantilever, knife edge suspensions  long period, high sensitivity T Capacitance pick up Symmetry, same material (pendulum + structure), thermal expansion/contraction effects dominant in one (vertical) direction should minimize distortions and spurious tilts (Construction drawings and electronics ready)

More Related