1 / 10

AGS Status

AGS Status. Haixin Huang. RSC Meeting April 6, 2012. Status. Continued to provide pp beam for RHIC physics program.

truman
Download Presentation

AGS Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AGS Status Haixin Huang RSC Meeting April 6, 2012

  2. Status • Continued to provide pp beam for RHIC physics program. • During the setup for Au beam in Booster, a radius wobbling was eliminated. The injection instability with beam intensity higher than 5.3*10^11 disappeared. We can continue to use the regular Booster scraping, instead of shift it earlier in the cycle (did not quite work). • Frequent sudden lurch of vertical dipole correctors in AGS was first noticed last Saturday. It was traced back to start after maintenance day. After several attempts to remove it, it disappeared but not correlated with the changes we made. • Tried shorter AGS cycle to fill RHIC twice. One jump quad tripped due to high temperature often in the faster cycle. We managed to fill RHIC twice but both ramps failed before rotator ramp. Keep running in this mode is kind of risky. So we backed off and waiting for possible P/S cooling improvement. • Lower polarization at AGS extraction. Correlated to lower input intensity (less Booster scraping). • We also observed irregular spin sign during AGS polarization measurements. Haixin Huang

  3. Booster Input Intensity and RHIC Intensity Lower Booster input intensity since Maintenance day (Mar. 28) Haixin Huang

  4. AGS Polarization for RHIC Fills Haixin Huang

  5. AGS Intensity and sin9v Amplitude (bad state) Haixin Huang

  6. AGS Intensity and sin9v Amplitude(2) (good state) Haixin Huang

  7. AGS Intensity and sin9v Amplitude (3) The improvement did not lined with function generator change (blue) and P/S change (green) but the switch from Uranium user. Remains as mystery. Haixin Huang

  8. Spin Sign Misbehavior It is under investigation, hope it does not affect RHIC injection. Haixin Huang

  9. AGS Horizontal Emittance for RHIC Fills Haixin Huang

  10. AGS Polarization for RHIC Fills (255GeV) Haixin Huang

More Related