1 / 31

Copper Functioning as an Oxygen Carrier in Chemical Looping Combustion

Copper Functioning as an Oxygen Carrier in Chemical Looping Combustion. Authors: Richard Baraki , Dr. Gabor Konya, Dr. Edward M. Eyring. Departments of: Chemistry and Chemical Engineering. Chemical Looping Combustion. Observed Oxygen Carrier. Copper 2 Cu(s) + O 2 (g)↔ 2 CuO(s).

tiger-wiley
Download Presentation

Copper Functioning as an Oxygen Carrier in Chemical Looping Combustion

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Copper Functioning as an Oxygen Carrier in Chemical Looping Combustion Authors: Richard Baraki, Dr. Gabor Konya, Dr. Edward M. Eyring. Departments of: Chemistry and Chemical Engineering

  2. Chemical Looping Combustion

  3. Observed Oxygen Carrier • Copper • 2 Cu(s) + O2(g)↔ 2 CuO(s) http://gwydir.demon.co.uk/jo/minerals/pix/copper1.jpg

  4. Method of Analysis • Thermogravimetric Analysis TA Q500 • ThermoFisher HP-TGA

  5. Copper • Overall oxidation 2 Cu(s) + O2(g)↔ 2 CuO(s) • Cu → Cu(I) 4Cu(s) + O2(g)↔ 2Cu2O(s) • Cu(I) → Cu(II) 2Cu2O(s) + O2(g)↔ 4 CuO(s)

  6. 2 days of looping (200+ loops) @ 850 °C

  7. Looping

  8. Cu(I) →Cu(II) Cu(I) →Cu(II) @ 850 °C Fitted Cu(I) →Cu(II) @ 850 °C

  9. Residual plot Residual of Y, (mg) Independent Variable, (sec)

  10. Pseudo first order equation • First-order reaction • r = -d[A]/dt = k[A] • k = rate constant • A = amount of copper • Pseudo first order reaction for • r = k[A][B]1/2 = k΄[A] • k = rate constant • k΄ = k[B]1/2 • A= amount of copper • B= partial pressure of oxygen

  11. Method of fit y = Wf + (Wi - Wf) * e(-k * (t-t0)) • Fitted Parameters • Wf - final weight of oxide • Wi - initial weight of oxide • k- rate constant • Fixed Parameter • t0- indicates start of reaction

  12. Shifting k values (TA-Q500)

  13. Shifting k values (HP-TGA)

  14. Cu2O/CuO/Cu2O system

  15. Temperature effects • Sintering • Tamman Temperature

  16. Pressure using HP-TGA • Pressure plots • 1 atm • 9 atm • 16atm • 25atm • Oxygen analyzer

  17. Pseudo first order equation • First-order reaction • r = -d[A]/dt = k[A] • k = rate constant • A = amount of copper • Pseudo first order reaction for • r = k[A][B]1/2 = k΄[A] • k = rate constant • k΄ = k[B]1/2 • A= amount of copper • B= partial pressure of oxygen

  18. Experimental Procedure • Sample loaded into quartz bucket • 200mg copper powder • Chamber closed and purged with pure nitrogen 15+ min • Temperature ramp from 21°C to 950°C in pure nitrogen gas at 25°C/min • Given experiment, pressure build up • At desired temperature and pressure, air is introduced

  19. Observations • Stoichiometric conversion • Rate at which sample is being oxidized

  20. Oxidation at different pressures Cu →CuO

  21. Observations • Stoichiometric conversion

  22. Oxidation at different pressures Cu →CuO

  23. Observations • Stoichiometric conversion • Rate at which sample is being oxidized

  24. Oxidation at different pressures Cu →CuO

  25. Reaction Rates for Range of Mass Increases of 101 to 105%: Decrease in rate with increasing pressure indicative of diffusional limitations

  26. Theoretical rates versus experimental rates based on the pseudo-first order model, to be revisited after experimental constraints eliminated Cu →CuO

  27. Oxygen analyzer Gas cylinders HP-TGA

  28. Oxygen concentrations at exit of reactor corresponding to HP-TGA plots previously shown. Failure to reach 21% to be explored Oxygen analysis of Cu →CuO Cu →CuO

  29. Oxygen analysis of Cu →CuO

  30. Conclusion • Pseudo first order model does not fit Cu/Cu2O/CuO system • Data indicate diffusional limitations

  31. Acknowledgements • Department of Energy • under Award Number DE-NT0005015. • Dana Overacker • Kevin Tucker • Blake R. Wilde