1 / 15

PemPlant Co.

E. P. M. PemPlant Co. April 5, 2007 Initial Prototype Presentation. Maricela Delgadillo Kay Furman Yushan Kim. Overview. Update Methylene blue staining: more results Contact angle results Mechanical force probe update Initial prototype Future characterization steps.

thawes
Download Presentation

PemPlant Co.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. E P M PemPlant Co. April 5, 2007 Initial Prototype Presentation Maricela Delgadillo Kay Furman Yushan Kim

  2. Overview • Update • Methylene blue staining: more results • Contact angle results • Mechanical force probe update • Initial prototype • Future characterization steps

  3. Methylene Blue Staining • glass: UV vis. possible • Ti: opaque, only qualitative analysis possible.

  4. Contact Angle Measurements • Samples Tested • Bare Ti, glass, 2.0/2.0 crosslinked, 3.0/3.0 crosslinked and uncrosslinked • DI water used as Solvent • Average of three measurements

  5. Reference Data • For 3.0/3.0 system • Contact: 61 • Receding: <10 • For 2.0/2.0 system • Contact: <10 Yang, S. Y.; Mendelsohn, J. D.; Rubner, M. F. Biomacromolecules. 2003, 4 (4), 987-94

  6. Results for Glass System • Glass • Contact: 83.7º • Receding: 73º • 2.0/2.0 Crosslinked • 10.6º • 3.0/3.0 Crosslinked • 29.45º • 3.0/3.0 Uncrosslinked • 12.4º Glass 2.0/2.0 x-linked

  7. Results for Ti System 2.0/2.0 x-linked • Bare Ti • 38.3º • 2.0/2.0 Crosslinked • 31.35º • 3.0/3.0 Crosslinked • 80.2º • 3.0/3.0 Uncrosslinked • 67.4º 3.0/3.0 un x-linked

  8. Results • Bare Ti Lit review measures about 100º • Lower value may be due to surface roughness • Significant increase in contact angle measurements on Ti surfaces as compared to Glass • Polymer film on Ti results in a more hydrophobic surface • Glass system results in a more hydrophillic surface

  9. Initial Prototype • Cleaning: acetone wipe, ethanol sonication • Layers: • Polyanion (PAA) 15min, rinse 3x (2, 1, 1 min) • Polycation 15 min, rinse 3x (2, 1, 1 min)

  10. Next Characterization Steps • Mechanical Force Probe • Initial training completed • Practice data analyzed • Stability tests • Wear test • Antibacterial testing over prolonged time periods • Aqueous environment film durability • Shelf life test: Characterize our oldest films Final Prototype

  11. Mechanical Wear Test Motivation Simulate handling during implantation procedure Operating room conditions: Devices handled sterilely Potential handling by surgical nurse and physician Nitrile glove protected hands Risk of coating removal: Loss of antibacterial coating Potential for bacterial infection from: Skin exposure (wound) Air 11 PemPlant Co.

  12. Mechanical Wear Test 12 • Goal: Assess coating delamination risk from handling • Parameters: • Glove probe surface • Typical handling load • Number of cycles • Design and build testing apparatus • Standard Test Method • ASTM G99-04 • “Wear testing with a Pin-on-Disk Apparatus” PemPlant Co.

  13. Wear Test Apparatus 13 • Equipment: • Variable speed motor • Disk and pin setup • Sample stand • Gloved probe • Design under development PemPlant Co.

  14. Wear Test Data Analysis 14 • Need tool to assess coating wear • Ideal analysis method: • Quantitative • Comparative • Sensitive • Timely • Current characterization methods: • MFP (long T) • Methylene blue (less sensitive) PemPlant Co.

  15. Gantt Update • Website: http://web.mit.edu/3.042/team1_07/Website/Website/ Contains this and all previous presentations

More Related