1 / 24

Ropes

Ropes. Intermediate SFFMA Objectives: 28-02.01 – 28-02.03 6Hrs received. SFFMA Objectives. 28-02.01 Trainee, given the proper rope, shall demonstrate the bight, loop, round turn, and half hitch as used in tying knots and hitches.

tala
Download Presentation

Ropes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ropes Intermediate SFFMA Objectives: 28-02.01 – 28-02.03 6Hrs received

  2. SFFMA Objectives • 28-02.01 Trainee, given the proper rope, shall demonstrate the bight, loop, round turn, and half hitch as used in tyingknots and hitches. • 28-02.03 Trainee shall demonstrate the technique of inspection, cleaning, maintaining, storage, safety procedures, and reasons for placing a rope out of service. • 28-02.02 Trainee, using an approved knot, shall hoist any selected forcible entry tool, ground ladder, or appliance to aheight of at least 20': • A. a 1½ inch or 1¾ inch dry hose with nozzle attached • B. a 2½ inch or 3 inch dry hose with nozzle attached • C. a 1½ inch or 1¾ inch charged hose • D. an axe • E. a 6' or 8' pike pole • F. a single 14' or 16' (wall) ladder • G. a 10' collapsible ladder • H. a 14' combination ladder • I. working as a member of a team, a 24' extension ladder • J. a 15 lb. CO2 fire extinguisher • K. a 20 lb. dry chemical fire extinguisher • L. an electric smoke ejector • M. a pair of bolt cutters

  3. Knot Characteristics • To be suitable for rescue, must be easy to tie and untie, be secure under load, reduce rope’s strength minimally • Rope’s strength reduced whenever bent • Bight, loop, round turn — Bends in rope • Knots, hitches formed by combining bending elements Firefighter I

  4. Knot Elements • Bight — Formed by bending rope back on itself while keeping sides parallel (Continued) Firefighter I

  5. Knot Elements • Loop — Made by crossing side of bight over standing part (Continued) Firefighter I

  6. Knot Elements • Round turn — Consists of further bending one side of loop Firefighter I

  7. Commonly Used Knots • Half-hitch • Particularly useful in stabilizing tall objects being hoisted; always used with another knot or hitch • Formed by making round turn around object • Several can be applied in succession if required (Continued) Firefighter I

  8. Removing Life-Safety Rope From Service • Life-safety rope that fails to pass inspection or has been impact loaded should be destroyed immediately • Destroy = Altered in such a manner that it cannot be mistaken for life-safety rope (Continued) Firefighter I

  9. Removing Life-Safety Rope From Service • Rope subjected to impact loading must have entry made in log because there is no way to determine by inspection if it has been impact loaded Firefighter I

  10. General Rope Maintenance Guidelines • Inspect all types after each use • Unused should be inspected at least annually • Inspect visually and by touch • Inspect for foreign objects; if found, take out of service • All inspections documented in log Firefighter I

  11. Types of Rope — Maintenance • Kernmantle rope • Laid rope • Braided rope • Braid-on-braid rope Firefighter I

  12. Maintaining Rope Log • When rescue rope is purchased, it must be permanently identified • Record must be started and kept throughout rope’s working life Firefighter I

  13. Cleaning Rope • Methods vary by manufacturer; contact for specific instructions • Natural fibers • Synthetic fibers Firefighter I

  14. General Rope Storage Considerations • Can be stored in coils or rope bags • Should be stored in clean, dry spaces with adequate ventilation • Not exposed to chemical contaminants • Not stored in same space with gasoline-powered tools, spare fuel (Continued) Firefighter I

  15. Bagging Rope • Best method for life-safety rope is to place in storage bag • Bag makes rope easy to transport, protects rope from contamination • Advantage of storing synthetic rope in bag is that rope can be deployed quickly (Continued) Firefighter I

  16. Bagging Rope • Weight of the rope inside bag carries it toward target and rope pays out as bag travels through air • Bag may have drawstring and shoulder straps for ease in carrying Firefighter I

  17. Coiling/Uncoiling Rope • Coiling necessary so rope may be placed into service with minimum delay important in fire service • Improperly coiled rope may become tangled and fail to uncoil Firefighter I

  18. Using Rope for Hoisting • One of most common uses of rope in fire service — Raise or lower tools and pieces of equipment from one elevation to another (Continued) Firefighter I

  19. Using Rope for Hoisting • Thorough knowledge of knots, hitches makes this a safe, efficient practice • Anything with closed-type D-ring handle can be raised, lowered with bowline or figure-eight bend • Hoisting pressurized cylinders not recommended (Continued) Firefighter I

  20. Using Rope for Hoisting • Using proper knots, securing procedures helps prevent dropping of equipment • Separate guideline may be tied to any of these pieces of equipment; objects may also be tied in center of rope Firefighter I

  21. Hoisting Safety — General • Have solid footing, make necessary preparations beforehand • Use hand-over-hand method • Use edge roller or padding • Work in teams (Continued) Firefighter I

  22. Hoisting Safety — General • Look to ensure all personnel clear of hoisting area • Avoid hoisting operations near electrical hazards • Secure nozzles of charged hoselines • Use guideline to help control object being hoisted Firefighter I

  23. Hoisting Safety • Hoisting • Axe • Pike pole • Ladder • Hoselines • Portable fans • Power saw Firefighter I

  24. Practical Exercise • Instructor will choose separate items for each firefighter • Firefighter using an approved knot, shall hoist any selected forcible entry tool, ground ladder, or appliance to a height of at least 20': • a 1½ inch or 1¾ inch dry hose with nozzle attached • a 2½ inch or 3 inch dry hose with nozzle attached • a 1½ inch or 1¾ inch charged hose • an axe • a 6' or 8' pike pole • a single 14' or 16' (wall) ladder • a 15 lb. CO2 fire extinguisher • a pair of bolt cutters