1 / 46

MEG Experiment

MEG Experiment. m ->e g branching ratio. Present limit: 1.2x10 -11. LFV process Forbidden in the SM Sensitive to SUSY-GUT, SUSY-seesaw etc. Our goal : Br( m ->e g )>10 -13 ~10 -14. Clear 2-body kinematics. 52.8 MeV. 180 °. 52.8 MeV.

tahlia
Download Presentation

MEG Experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MEG Experiment

  2. m->eg branching ratio Present limit: 1.2x10-11 • LFV process • Forbidden in the SM • Sensitive to SUSY-GUT, SUSY-seesaw etc. • Our goal : Br(m->eg)>10-13~10-14 Clear 2-body kinematics 52.8 MeV 180° 52.8 MeV Michel decay (μ+→e+νeνμ) + random γ Background Rate ~ 10-14 Radiative muon decay (μ+→e+νeνμγ) Background Rate < 10-14 Only allowed after KamLAND Motivation & Event Signature

  3. Xe Detector Approved in 1999, at Paul Scherrer Institut, in Switzerland COBRA 252cm Timing Counter Physics run in 2006 Initial goal at 10-13, finally to 10-14 m+ beam : World’s most intense DC Beam 108m+/s g detector : 800liter liquid xenon scintillation detector with 830 PMTs e+ detector: solenoidal magnetic spectrometer with a gradient magnetic field (COBRA) m+ 262cm DriftChamber MEG Experiment & Detector

  4. Experimental Hall • The most powerful machine in the world. • Proton energy: 590MeV • Nominal operation current: 1.8mA. • Max > 2.0mA possible. Paul Scherrer Institut

  5. Small Prototype

  6. Small Prototype • 32 2-inch PMTs surround the active volume of 2.34 liter • g-ray sources of Cr,Cs,Mn, and Y • asource for PMT calibration • Operating conditions • Cooling & liquefaction using liquid nitrogen • Pressure controlled • PMT operation of 1.0x106 gain • Proof-of-Principle Experiment • PMT works in liquid xenon? • Light yield estimation is correct? • Simple setup to simulate and easy to understand. S.Mihara et al. IEEE TNS 49:588-591, 2002

  7. Small PrototypeEnergy resolution • Results are compared with MC prediction. • Simulation of g int. and energy deposition : EGS4 • Simulation of the propagation of scint. Light EGS cut off energy : 1keV Rayleigh Scattering Length: 29cm Wph = 24eV

  8. Small PrototypePosition and Timing resolutions • PMTs are divided into two groups by the y-z plane • gint. positions are calculated in each group and then compared with each other. • Position resolution is estimated as sz1-z2/√2 • The time resolution is estimated by taking the difference between two groups. • Resolution improves as ~1/√Npe

  9. Large Prototype

  10. Large Prototype • 70 liter active volume (120 liter LXe in use) • 372x372x496 mm3: 17.3 R.L. in depth • Development of purification system for xenon • Total system check in a realistic operating condition: • Monitoring/controlling systems • Sensors, liquid N2 flow control, refrigerator operation, etc. • Components such as • Feedthrough,support structure for the PMTs, HV/signal connectors etc. • PMT long term operation at low temperature • Performance test using • 10, 20, 40MeV Compton g beam • 60MeV Electron beam • g from p0 decay

  11. TERAS g Beam • Compton Spectrum • (Eg-Ec/2)2+(Ec/2)2 • Electron beam (TERAS, Tsukuba in Japan) • Energy: 764MeV • Energy spread: 0.48%(sigma) • Divergence: <0.1mrad(sigma) • Beam size: 1.6mm(sigma) • Laser photon • Energy: 1.17e-6x4 eV (for 40MeV) • Energy spread: 2x10-5 (FWHM) • Divergence: unknown • Beam size: unknown Collimator size 10MeV 20MeV 40MeV

  12. Energy Spectrum Fitting • Suppose Compton Spectrum around the edge • (E-Ec/2)2+Ec2/4 • Detector Response Function • Gaussian with Exponential tail • f(x) = N*exp{t/s2(t/2-(x-x0)}, x<x0+t • N*exp{-1/2((x-x0)/s)2}, x>x0+t • Convolution • Integration +/- 5s • Principle… Eg Npe Convolution of Compton Spectrum Response Function sE~1.9%

  13. 1. TERAS Beam Test Inverse Compton g Energy : 10, 20, 40 MeV Incident Position : Detector Center Estimate Energy Resolution using Compton Edge 40MeV g Energy 40MeV g Vertex distribution 1.6% in s 3.8mm in s

  14. 175° 80MeV q Eg Eg p0 Energy (MeV) 55MeV 170° 155° Opening angle (deg) 54.9MeV 82.9MeV Energy (MeV) p0 Beam Test at PSI Concept p- (at rest) + p -> p0 + n, p0(28MeV/c) -> g + g • Requiring q>170o • FWHM = 1.3 MeV • Requiring q > 175o • FWHM = 0.3 MeV Opening angle selection of two g’s  monochromatic g 180°

  15. Beam Test Setup H2 target+degrader LYSO Eff ~14% NaI LP S1 Eff(S1xLP)~88% beam

  16. 115cm 115cm • p- (at rest) + p -> p0 + n, • p0(28MeV/c) -> g + g • monochromatic g calibration • of around 52.8MeV • p- + p -> n(8.9MeV) + g (129MeV) • linearity check & neutron response LP Xe 8x8NaI g n p-p->np0, p0->2g p- LP Xe total charge To get Energy Resolution Select p0 events Select NaI energy Select incident position in Xe detector Remove too shallow and too deep events p-p->ng NaI Energy (MeV) p0 Beam Test at PSI

  17. Energy Resolutions CEX 2004 55 MeV 83 MeV to Xe • = 1.23 ±0.09 % FWHM=4.8 % 55 MeV to Xe EXe[Nph] 83 MeV σ= 1.00±0.08 % FWHM=5.2%

  18. Energy Resolution vs Energy PSI 2003 TERAS 2003 alpha Right  is a nice function of gamma energy

  19. Position Reconstruction • Localized Weight Method • Projection to x and y directions. • Peak point and distribution spread • Position reconstruction using the selected PMT

  20. Examples of Reconstruction (40 MeV gamma beam w/ 1 mm collimator)

  21. Position ReconstructionResolution

  22. g Reconstruction of the event depth • Using event broadness on the inner face • Necessary to achieve good timing resolution

  23. g MC simulation Data D D Short labs Previous Test D= • D: depth parameter D: 20~100  0~25cm D Long labs This Test D D

  24. Energy Resolution vs. Depth Parameter • For g incident at the detector center • D > 35, 45, 55….85 • Resolution: < 2% in sigma except shallow events (D<45). D Number of Photoelectrons

  25. Nfpmt(0.5) • Another depth parameter: Nfpmt(0.5) • Sort front-face PMTs in the order of the distance to the x-y weighted mean position. • Sum up PMT output in that order. • Stop summing when the sum exceeds the half of Qsum[Front]. •  Number of PMTs used in the SUM. QPMT 1.0 Shallow Deep 0.5 NPMT

  26. Timing/Z Resolution p- • Improving Z resolution is essential to improve timing resolution. • Intrinsic timing resolution can be evaluated by comparing left and right parts of the detector. • <T> = (TLTR)/2 NaI g S1 Xenon g LYSO tLP - tLYSO TL Left Right TR g

  27. Absolute timing, Xe-LYSO analysis high gain normal gain 103 psec 110 psec 55 MeV Normal gain High gain A few cm in Z

  28. Timing Resolution <TL>-<TR> • Estimated using Electron Beam (60MeV) data • Resolution improves in proportion to 1/sqrt(Npe). • For 52.8 MeV g, s~60 psec + depth resolution. • QE improvement and wave-form analysis will help to achieve better resolution. (Visit “The DRS chip” by S.Ritt) s=75.6+/-2.0ps 45 MeV Energy deposit by 60 MeV electron injection s Timing Resolution (psec) 52.8MeV g (nsec) 104 4x104 Number of Photoelectron

  29. PMT Development

  30. Photomultiplier R&D Ichige et al. NIM A327(1993)144 • Photocathode • Bialkali :K-Cs-Sb, Rb-Cs-Sb • Rb-Cs-Sb has less steep increase of sheet resistance at low temperature • K-Cs-Sb has better sensitivity than Rb-Cs-Sb • Multialkali :+Na • Sheet resistance of Multialkali dose not change so much. • Difficult to make the photocathod, noisy • Dynode Structure • Compact • Possible to be used in magnetic field up to 100G • Metal channel  Uniformity is not excellent

  31. PMT (HAMAMATSU R6041Q) • Features • 2.5-mmt quartz window • Q.E.: 6% in LXe (TYP) (includes collection eff.) • Collection eff.: 79% (TYP) • 3-atm pressure proof • Gain: 106 (900V supplied TYP) • Metal Channel Dynodethin and compact • TTS: 750 psec (TYP) • Works stably within a fluctuation of 0.5 % at 165K 32 mm 57 mm

  32. PMT DevelopmentSummary

  33. Motivation • Under high rate background, PMT output (old Type PMT, R6041Q) reduced by 10-20%. • This output deterioration has a time constant (order of 10min.): Related to the characteristics of photocathode whose surface resistance increases at low temperature. • Rb-Sc-Sb + Mn layer used in R6041Q • Not easy to obtain “high” gain. Need more alkali for higher gain. • Larger fraction of alkali changes the characteristic of PC at low temp. So, New Type PMTs, R9288 (TB series) were tested under high rate background environment. • K-Sc-Sb + Al strip used in R9288 • Al strip, instead of Mn layer, to fit with the dynode pattern Confirmed stable output. ( Reported in last BVR) But slight reduction of output in very high rate BG Add more Al Strip Al Strip Pattern • Low surface resistance R9288 ZA series Yasuko HISAMATSU MEG VRVS Meeting @PSI June 2004

  34. Gas Purification

  35. He H2O CO/N2 O2 Xe CO2 Possible Contaminants • Residue Gas Analysis • Vacuum level • LP Chamber 2.0x10-2Pa • Analyzing section 2.0x10-3Pa H2O is the most dangerous for Xe scintillation light

  36. Gas return To purifier Circulation pump Purification System • Xenon extracted from the chamber is purified by passing through the getter. • Purified xenon is returned to the chamber and liquefied again. • Circulation speed 5-6cc/minute

  37. Gas return To purifier Circulation pump Purification System • Xenon extracted from the chamber is purified by passing through the getter. • Purified xenon is returned to the chamber and liquefied again. • Circulation speed 5-6cc/minute • Enomoto Micro Pump MX-808ST-S • 25 liter/m • Teflon, SUS

  38. Simulated data Measured/MC Before purification: ~10 ppm After purification: ~10 ppb How much water contamination?

  39. Purification Performance • Xenon Detector Large Prototype • 3 sets of Cosmic-ray trigger counters • 241Am alpha sources on the PMT holder • Stable detector operation for more than 1200 hours Cosmic-ray events a events

  40. Xenon Purifier • Attenuation of Sci light • Scintillation light emission from an excited molecule • Xe+Xe*Xe2*2Xe + hn • Attenuation • Rayleigh scattering lRay~30-45cm • Absorption by impurity

  41. Absorption Length • Fit the data with a function : A exp(-x/ labs) • labs >100cm (95% C.L) from comparison with MC. • CR data indicate that labs > 100cm has been achieved after purification.

  42. Liquid Phase Purification

  43. In ~10 hours, λabs ~ 5m Liquid-phase Purification Performance

  44. PET vs MEG • 511 keV vs 52.8 MeV • Smaller number of photo-electron • Shallower detector • Read out from back vs from front • Smaller light collection • Efficient detection • Small amount of material in front • Efficient fiducial volume • Mild requirement on resolutions

  45. The End

More Related