1 / 24

SPECTROPHOTOMETRY

SPECTROPHOTOMETRY. Spectrophotometry. Determines concentration of a substance in solution Measures light absorbed by solution at a specific wavelength. Spectrophotometry.

taariq
Download Presentation

SPECTROPHOTOMETRY

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SPECTROPHOTOMETRY

  2. Spectrophotometry • Determines concentration of a substance in solution • Measures light absorbed by solution at a specific wavelength

  3. Spectrophotometry • One of the simplest and most widely used methods to determine the amount of protein or nucleic acid present in a given solution

  4. Spectrophotometry • Proteins do not absorb in visible wavelength region unless they have a prosthetic group (e.g., Fe2+), or an unnatural amino acid

  5. Spectrophotometry • Visible region: low energy electronic transition due to: a. Compounds containing transition metals b. Large aromatic structures & conjugated double bond systems (vitamin A, heme) • UV region (200-400 nm): a. Small conjugated ring systems (Phe, Tyr, Trp)

  6. Spectrophotometry Io I A = 0.012  l  Lamp Monochromator Detector Cuvette

  7. Spectrophotometers • Light source (Lamp) • Optical filters or prism • Tube or cuvette • Photocell or photomultiplier tube

  8. Light source (Lamp) • Visible region = tungsten or tungsten-halogen • UV light = deuterium or hydrogen lamp

  9. Optical filters/prisms • To limit light to a certain wavelength • Monochromator can isolate a specific wavelength of white light and allow it to pass through the solution being analyzed

  10. Tubes or cuvettes • Visible range = glass cuvette • UV range = quartz cuvette

  11. Photocell • To detect transmitted light

  12. Spectrophotometry • Beer-Lambert’s Law log Io = cl I Where: Io = intensity of incident light I = intensity of transmitted light  = molar extinction coefficient c = concentration of the absorbing species (mol/L) l = path length of the light-absorbing sample (cm)

  13. Beer-Lambert’s Law • The fraction of the incident light absorbed by a solution at a given wavelength is related to a. thickness of the absorbing layer (path length) and b. concentration of the absorbing species

  14. Visible region wavelength

  15. Beer-Lambert’s Law • Concentration  amount of light absorbed A = abc = log(100/%T) Where A = absorbance a = absorptivity of the compound under standard conditions b = light path of the solution c = concentration of the compound %T = percent transmittance

  16. Beer-Lambert’s Law • Absorbance A = K x C = Log10Io I Where: Io = amount of light absorbed by the solution expressed as absorbance or optical density K = constant C = concentration of the substance

  17. Transmittance • Defined as the ratio of the intensity of light emerging from the solution (I) to that of incident light entering (Io) T = I Io Io I

  18. Transmittance • Inversely related to the concentration of the solution and is expressed in % % T = 1 x 100 Io

  19. Transmittance • 100% transmittance means no light is absorbed by the solution so that incident light is 100% transmitted

  20. Absorbance & Transmittance • Absorbance  concentration • Transmittance 1/  to concentration and absorbance

  21. Sample Problem • Cytosine has a molar extinction coefficient of 6 x 103 mol-1 cm-1 at 270 nm at pH 7. Calculate absorbance of 1 x 10-3 M cytosine solution in 1mm cell at 270 nm A = Log I0= lc I

  22. Sample Problem • Solution: 1. A = lc = (6 x 103)x (0.1) x (1 x 10-3) = 6 x 10-1 = 0.6 (O.D.)

  23. Spectrophotometry • Clinical applications: 1. Aromatic amino acids have characteristic strong absorbance of light at a wavelength of 280nm ex. Tryptophan & tyrosine

  24. Calibration Curve

More Related