An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DCLL ½ port Test Blanket Module thermal-hydraulic analysis Presented by P. Calderoni March 3, 2004 UCLA

  2. Total heat balance Input parameters for the ½ port module (Wong, Sawan March 2005): Surface heat flux q’’ = 0.3 MW/m2 over 90% of FW / 0.5 MW/m2over 10% of FW First wall surface = 1.94 m X 0.64 m = 1.25 m2 Power from radiative flux = 0.4 MW Nuclear heating power = 0.913 MW Total power handled by the module = 1.313 MW Power transferred to He cooling (40% of total) = 0.6 MW If inlet / outlet He temperature are fixed at 360 C and 440 C the needed cooling mass flux m’ = 1.265 kg/s (Cp = 5192 J/Kg K)

  3. Pressure losses along in/out pipes from HEX to TBM 40 m/s (52 m/s) Re = 5x105 8 kPa in coax (4.5 kPa w/o SiC) Why keeping the SiC insert? hydraulic diameter: 0.086 m Friction coefficient (Petukhov corr) = 0.013

  4. Pipes length L = 80 m x 2 (in / out) Pressure losses = 0.11 Mpa (1.375% of inlet pressure) 10 m 18 m 40 m 18 m

  5. Back View Side View turn0.5k Pressure losses in back-plate distribution circuit 90 turn 2k 30% flow split 2k up down Coaxial piping conv / div in transporter 8k x 2 Top, grid plates FW L to R pass FW R to L pass Bottom, grid plates 90 Y conv 8k 90 Y split 8k Pressure losses = 0.04 Mpa (0.0225 MPa w/o SiC) 0.5 % of inlet pressure (0.28 %) 30% flow split 2k 90 turn 2k turn0.5k

  6. Pressure losses in first wall cooling channels Grid Plate First Wall Vertical He I/O Manifold Grid Plate He Manifold [ DEMO design ]

  7. Initial design configuration: 0.024 m pitch 16 channels per section 0.884 kg/s total mass flow 1.255 m x 5 channel length v = 16.1 m/s h = 1375 W/m2 K dp = 3.6 kPa 0.442 kg/s 0.055 kg/s 20 mm 30 mm For q = 0.3 MW/m2 the heat transfer coefficient needs to be at least 4000 W/m2 K to ensure TFWmax < 550 C 38 mm 0.055 kg/s 0.442 kg/s

  8. Heat transfer could be enhanced by squared ribs perpendicular to the flow on the high heat flux side, as suggested by S. Sharafat (1 x 1 mm ribs with a 6.3 mm pitch) instead of smaller channel dimension. With similar heat transfer coefficient the ribbed channels configuration generates 64% of the total pressure losses than the smaller smooth channels. 10mm x 10 mm channels: 0.014 m pitch 32 channels per section v = 48.4 m/s h = 4000 W/m2 K dp = 75 kPa Cost? Efficiency at high heat flux? Reliability? 10mm x 15 mm channels: 0.014 m pitch 32 channels per section v = 32.3 m/s h = 2750 W/m2 K dp = 29 kPa 20mm x 20 mm channels: 0.024 m pitch 16 channels per section v = 24.2 m/s h = 2000 W/m2 K dp = 9.4 kPa Preliminary results from 2-D simulation of He flow in the FW channels and manifolds by G. Sviatoslavsky show pressure drops that are a factor of 3 higher than those evaluated with Petukhov’s correlation for the channels only. Estimated total pressure drop in FW = 0.225 MPa (2.8% of inlet pressure)

  9. Pressure losses in top, bottom and grid plates (design not finalized) 0.38 kg/s (30% of total flow) is diverted to cool all structures other than the FW. If a channel geometry similar than the FW is assumed a pressure loss of 10 kPa can be used as a first approximation for each cooling plate Estimated total pressure losses = 0.050 MPa (0.6% of total inlet pressure)

  10. Summary • Eliminate SiC insert from He coaxial pipe (suggested) • Use ribs to enhance heat transfer (questionable) • Without a finalized design a lower boundary for pressure losses could be found by scaling the FW losses with v2 (use higher value to be conservative)