1 / 14

Wall / V 12

Wall / V 12. V 12. Introduction. Arguments. Technical details. Installation. Introduction. Arguments. Technical details. Installation. V 12 / Introduction. The V 12 range.

step
Download Presentation

Wall / V 12

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wall /V 12 V 12 Introduction Arguments Technical details Installation

  2. Introduction Arguments Technical details Installation V 12 /Introduction The V 12 range The V 12 range includes 2.5, 3.5, 5.0 and 6.5 kW mono split units, as well as 2x1 multi splits. All of them working with ON-OFF technology. V 12 models have a modern design with a new bright digital display. Moreover, it includes an enhanced health air purifying system, and functions such as Low Noise, Sleep Function and Light Control.

  3. Arguments Introduction Technical details Installation V 12 / Arguments /Features DC INVERTER REMOTE CONTROL HIGH EFFICIENCY COLORFUL LCD DIGITAL DISPLAY BIO BACTERIA KILLING LOW NOISE SLEEP FUNCTION COLD CATALYST FILTER TIMER AUTO OPERATION 2x1 DUST FILTER VERTICAL AIR SWING LIGHT CONTROL Modern Design The series comes with elegant blue color display which provides useful information for the user. Air purifying This series includes a complete health air purifying system consisting of three filters; a cold catalyst filter, a bio filter and 2x1 anti dust filter. High Comfort Customer focused design and improved functions like Low noise and Vertical air swing provide more comfort to end users. High Efficiency The majority of the range is A class energy efficiency. Our DC Inverter Solution – Inverter Technology High modulating DC Inverter technology provides high efficiency, low sound and high comfort.

  4. Arguments Introduction Technical details Installation V 12 / Arguments /USPs Modern design Easily controlled by remote control With several functions including green light ON-OFF function on indoor display. New display Bright digital display with elegant blue colour provides users with useful information such as Operation mode, Sleep function and Set temperature. It is a clear differentiation when compared with more simple LED lamps displays.

  5. Arguments Introduction Technical details Installation V 12 / Arguments /USPs Air purifying Anti dust 2x1 filter This filter neutralizes and protects the ambient air from acarus, microbes and dust through its unique 2 in 1 effect (it is also antiallergenic and antibacterial). Bio filter A layer of special material is installed in the filtration network of the unit. When the unit starts working, slow release technology purifies the ambient air, providing moisturization and improving health effects on the skin. Cold catalyst filter This filter has anti-odour and sterilization effects. It can completely degrade methyl oxide (which has cancerogenic effects) from the ambient air. It also effectively removes odd odours like those of methyl hydrosulfate, ethyl mercaptan etc. Compared with optical catalyst filters, the cold catalyst has the advantage of recycling without going through the regeneration process.

  6. Arguments Introduction Technical details Installation V 12 / Arguments /USPs Comfort Customer focused design provides more comfort to end users. Special functions such as Sleep function, Auto operation, a complete Health Air Purifying system, Light control via remote button, Universal indoor and Low noise are designed to bring comfort to the final users. HEALTH AIR PURIFYING LIGHT CONTROL AUTO (it is possible to choose the temperature in this mode) SLEEP LOW NOISE

  7. Arguments Introduction Technical details Installation V 12 / Arguments /USPs High efficiency ‘A’ Class range provides optimum comfort with minimum consumption of energy. More efficient Cost Savings Energy More savings More efficient Less efficient Less efficient Less savings

  8. Technical details Introduction Arguments Installation V 12 / Technical Details /Technical Specifications

  9. Technical details Introduction Arguments Installation V 12 / Technical Details /Technical Specifications

  10. Technical details Introduction Arguments Installation V 12 / Technical Details /Temperature range

  11. Technical details Introduction Arguments Installation V 12 / Technical Details /Drawings Indoor dimensions Outdoor dimensions

  12. Installation Introduction Arguments Technical details V 12 /Installation Mono split Max. Pipe Length = a + b + c = a + d + e Max. Height IU under OU = h2 Max. Height OU under IU = h1

  13. Installation Introduction Arguments Technical details V 12 /Installation Multi split Total Max. Length = L1 + L2 + L3 Max. Height IU under OU = h2 Max. Height OU under IU = h1 L1 = a + b + c L2 = d L3 = e + f + g Max. single pipe length = L1 = L2 = L3

  14. Controls / Remote controls / Description /V 12 Increases/Decreases the temperature by 1ºC and sets the timer Switches the device ON-OFF Selects the mode: AUTO/COOL/DRY/HEAT/FAN Directs the airflow up/down Directs the airflow up or down Adapts the temperature during night time Selects the Timer start-up time Starts working at maximum fan speed Activates the ion operation (function not available) Switches off the light of the indoor display Locks the remote control button

More Related