1 / 20

NEMO-3 A search for double beta decay

NEMO-3 A search for double beta decay. Robert L. Flack University College London On behalf of the NEMO-3 collaboration. Overview. NEMO-3 The collaboration. The detector. The sources. Event reconstruction. Radon trapping facility (phase 1 and 2 data). Results Past Latest

stella
Download Presentation

NEMO-3 A search for double beta decay

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NEMO-3A search for double beta decay Robert L. Flack University College London On behalf of the NEMO-3 collaboration NEMO-3 Neutrino08

  2. Overview • NEMO-3 • The collaboration. • The detector. • The sources. • Event reconstruction. • Radon trapping facility (phase 1 and 2 data). • Results • Past • Latest • The future – SuperNEMO • Comparison with NEMO-3. NEMO-3 Neutrino08

  3. NEMO3(NeutrinoEttoreMajoranaObservatory) 60 physicists, 17 institutions NEMO-3 Neutrino08

  4. The NEMO-3 detector 20 sectors B(25 G) 3 m Magnetic field: 25 Gauss Gamma shield: Pure Iron (e = 18 cm) Neutron shield: 30 cm water (ext. wall) 40 cm wood (top and bottom) (since march 2004: water + boron) 4 m Particle ID: e-, e+, g and a Fréjus Underground Laboratory : 4800 m.w.e. Source: 10 kg of  isotopes cylindrical, S = 20 m2, e ~ 60 mg/cm2 Tracking detector: drift wire chamber operating in Geiger mode (6180 cells) Gas: He + 4% ethyl alcohol + 1% Ar + 0.1% H2O Calorimeter: 1940 plastic scintillators coupled to low radioactivity PMTs NEMO-3 Neutrino08

  5. bb2n measurement bb0nsearch bbdecay isotopes in NEMO-3 detector 116Cd405 g Qbb = 2805 keV 96Zr 9.4 g Qbb = 3350 keV 150Nd 37.0 g Qbb = 3367 keV 48Ca 7.0 g Qbb = 4272 keV 130Te454 g Qbb = 2529 keV External bkg measurement natTe491 g 100Mo6.914 kg Qbb = 3034 keV 82Se0.932 kg Qbb = 2995 keV Cu621 g (Enriched isotopes produced by centrifugation in Russia) NEMO-3 Neutrino08

  6. Vertex of the e-e- emission Source foils Scintillator + PMT Vertex of the e-e- emission Event reconstruction Transverse view Longitudinal view Observables of the final state • Trajectories of the 2 electrons • Energies of the 2 electrons • Time of flight • Curvature of the tracks in a B-field (+ or -). NEMO-3 Neutrino08

  7. Radon trapping facility Radon trapping facility (First developed for SuperKamiokande) Phase I : February 2003 – September 2004 (radon background in data) ~ 1 0nbb-like event/y/kg with 2.8 < E1+E2 < 3.2 MeV Phase II : since October 2004 (radon level reduced by a factor of 6) 1 ton of charcoal @ –50oC, 9 bars air flux = 150 m3/h Input: A(222Rn) 15 Bq/m3 Output: A(222Rn) < 15 mBq/m3 !!! reduction factor of 1000 Inside the NEMO 3 tent: factor of 100 – 300 Inside NEMO 3: almost factor of 10 A(222Rn)  6 mBq/m3 NEMO-3 Neutrino08

  8. 12000 10000 8000 6000 4000 2000 0 Number of events • Data-bkg = sig • Data-bkg = sig 22 Monte Carlo 22 Monte Carlo Background Background 100Mo 2results Angular distribution Sum energy spectrum 219 000 events 6914 g 389 days S/B = 40 219 000 events 6914 g 389 days S/B = 40 12000 10000 8000 6000 4000 2000 0 NEMO-3 NEMO-3 100Mo 100Mo Number of events/0.05 MeV Cos() E1 + E2 (MeV) T1/2(2nbb) = 7.11 ± 0.02 (stat) ± 0.54 (syst)  1018 years Phase 1: Feb. 2003 – Dec. 2004 “High Radon” Now have in excess of 0.5M events and will update later this year. Phys. Rev. Lett. 95 182302 (2005) NEMO-3 Neutrino08

  9. 2n results with other nuclei NEMO-3 932 g 389 days 2750 events S/B = 4 NEMO-3 454 g 534 days 109 events S/B = 0.25 82Se 130Te Preliminary: Result for Phase 1 and 2 data. 130Te: T1/2 = [7.6 ± 1.5 (stat) ± 0.8 (syst)]  1020 y Results for Phase I data. Additional statistics are being analysed and to be published soon. 82Se: T1/2 = [9.6 ± 0.3 (stat) ± 1.0 (syst) ]  1019 y 116Cd: T1/2 = [2.8 ± 0.1 (stat) ± 0.3 (syst) ]  1019 y 2nbbis important:1) Experimental input to NME calculation 2) Ultimate background for0nbb NEMO-3 Neutrino08

  10. New result: 48Ca bb High bkgs here due to contamination with 90Sr. Cut at 1.5 MeV NEMO-3 NEMO-3 Cut at 0 133 events S/B 6.76 948 days 7g E1 + E2 (MeV) Preliminary results: T1/2 (2nbb) = [4.4 +0.5-0.4 (stat) ± 0.4 (syst)] x 1019 y T1/2 (0) >1.3 x1022 y (90% C.L) <mn> < 29.6 eV (90%CL), Eff. 22% refs: E Caurrier et al., Phys. Rev. Lett. 100 (2008) 052503 (NME) NEMO-3 Neutrino08

  11. New result: 96Zr 2nbb NEMO-3 NEMO-3 925 days S/B 1.01 9.41g Preliminary result: 96Zr:T1/2 (2νββ)= [2.3 ± 0.2(stat) ± 0.3(syst) ]  1019 y T1/2 (2νββ)= 8.6  1021 y (90% C.L) <mn> < 7.4 - 20.1 eV (90%CL), Eff. 19% Refs for NME : Simkovic, et al., Phys. Rev. C 77 (2008) 045503 Kortelainen and Suhonen,Phys. Rev. C 76 (2007) 024315 NEMO-3 Neutrino08

  12. Recent result: 150Nd 2nbb (Moriond) 37g Preliminary results: 150Nd: T1/2 (2νββ) = [9.20 +0.25-0.22 (stat) ± 0.62 (syst)] x 1018 y T1/2 (0νββ) = 1.45 x 1022 y (90% C.L.) <mn> < 3.7 - 5.1 eV (90%CL), Eff. 19% Ref for NME : V. A. Rodin et al., Nucl. Phys. A 766 (2006)107 NEMO-3 Neutrino08

  13. 693 days of data Phase I + Phase II 0nbbof 100Mo and 82Se (To be updated) Data until spring 2006 693 days of data Phase I + Phase II NEMO-3 NEMO-3 82Se 100Mo T1/2 > 5.8 × 1023 y @ 90% C.L. mn < (0.8 – 1.3) eV [1-3] T1/2 > 2.1 × 1023 y @ 90% C.L. mn < (1.4 – 2.2) eV [1-3] [1] M.Kortelainen and J.Suhonen, Phys.Rev. C 75 (2007) 051303(R). [2] M.Kortelainen and J.Suhonen, Phys.Rev. C 76 (2007) 024315. [3] V.A.Rodin et al., Nucl.Phys. A 793 (2007) 213. NME: NEMO-3 Neutrino08

  14. SuperNEMO NEMO-3 isotope 82Se - baseline (150Nd if it can be enriched) 100Mo isotope massM 100-200 kg 7 kg 208Tl mBq/kg if 82Se: 214Bi  10 mBq/kg 208Tl: < 20 mBq/kg 214Bi: < 300 mBq/kg internal contaminations 208Tl and 214Bi in the bb foil energy resolution (FWHM) 8% @ 3MeV 4%@ 3 MeV T1/2(0nbb) > 2 x 1024 y <mn> < 0.3 – 0.9 eV T1/2(0nbb) > 1026 y <mn> < 0.04 - 0.11 eV From NEMO-3 to SuperNEMO NA Me Tobs T1/2 (bb0n) > ln 2   A N90 18 % efficiency  ~ 30 % See SuperNEMO poster NEMO-3 Neutrino08

  15. Summary • NEMO’s Tracking + Calorimetry approach is unique • Good rejection of backgrounds • Choice of isotopes • Reconstruction of kinematics • NEMO3 is taking data • 2nbb factory: precise life-time measurements for 7 isotopes (out of 9 main candidates). • New results for 48Ca and 96Zr. • Data taking until end 2010: 340-590 meV. • SuperNEMO: 3 year Design Study addresses most critical issue • Based on design study results full proposal for 100+ kg detector in 2009. • 82Se – baseline, 150Nd possible. • First module 2010/11. • All 20 modules ~2013. • Target sensitivity: 50-100 meV by 2016 NEMO-3 Neutrino08

  16. Backup slides NEMO-3 Neutrino08

  17. Schedule Summary 2010 2011 2007 2008 2009 2012 2013 BiPo construction 2014 NEMO3 Running SuperNEMO Design Study BiPo1 Canfranc/LSM BiPo installation BiPo running @ Canfranc SuperNEMO 1st module construction Preparation of new LSM site construction of 20 modules 1-5 SuperNEMO modules running at Canfranc Running full detector in 2014 Target sensitivity (0.05-0.1 eV) in 2016 SuperNEMO modules installation at new LSM NEMO-3 Neutrino08

  18. Choice of Isotope • Criteria of choice: • High Qbb value • Phase space G0n • 2nbb half-life • natural abundance • enrichment possibilities. Purification of 4kg of 82Se underway (INL, US). Enrichment of 150Nd possible. 82Se obtained by centrifugation. Impossible for 150Nd, only laser enrichment. NEMO-3 Neutrino08

  19. ββdecay is about background suppression Background. Natural radioactivity: T1/2(238U, 232Th) ~ 1010 yr T1/2(0nbb) > 1025 yr 238U and 232Th produce 214Bi (Qb = 3.27 MeV) and 208Tl(Qb = 4.99 MeV) Radon! Cosmogenic activitity Underground is a must Due to tracking, for SuperNEMO the main focus is on source (foil) purity. Must be super-duper-ultra low < 10 mBq/kg! (For reference humans 10-100 Bq/kg typical materials ~ 1Bq/kg) But how to measure these levels?! NEMO-3 Neutrino08

  20. Choice of site • Canfranc • 2500 m.w.e • LS Modane • 4800 m.w.e • Boulby • 2800 m.w.e Boulby Canfranc NEMO-3 Neutrino08