Do-more Technical Training

Learn how to connect C-more to Do-more by manually creating TAGs or by importing an exported Element Documentation file from Do-more Designer. Discover the limitations of the process.

sross
Download Presentation

Do-more Technical Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Do-more Technical Training Connecting C-more

  2. Connecting C-more • Two easy ways: • Create TAGs manually • …in C-more Programming • Create TAGs automatically • …by importing an exported Element Documentation file from Do-more Designer

  3. Connecting C-more • Create TAGs Manually: • Start C-more Programming Software • Press <Start a Project> button • Enter Project Name • Select panel • Select Do-more Protocol • AutomationDirectDo-more Ethernet • AutomationDirectDo-more Serial • NOTE: If this is picked make sure the Do-more port is set to “Do-more Programming” • Press <OK> button • Select Function tab, under Setup, double-click Panel Manager • Name Device, enter connection parameters (e.g. IP Address or Serial parameters) & password (if needed) • Press <OK> button

  4. Connecting C-more • Create TAGs Manually: • On Function tab, under Setup, double-click Touch Panel Network • Select Ethernet Port tab & enter desired parameters • Select Database  Tag Name Database…, then the <Add…> button • Enter Device Name, a Tag Name, a Tag Data Type, then select the Memory Type & Address in the Do-more from the pull-down menus • Enter all desired TAGs… • Press <OK>, then <Close> • Save Project & Send it to the panel

  5. Connecting C-more • Use Do-more’s exported Element Documentation file • In Do-more Designer (that has a documented project) select File  Export  Element Documentation • Choose the C-more Format desired: • Tag Name (Nickname), Value Type, Element, Block Type, Block Name • … PLUS All Used Elements • Name file & press <Save> button • In C-more Programming, select File  Import  Tag Name Database… • Check “From Do-more”, select File Path & Device, then press the <Import> button

  6. Connecting C-more • Limitations • No Heap Items • No user-created Memory Blocks