An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. In-situ AFM Tensile Testing ME 395 Professor Horacio D. Espinosa Chris Biedrzycki, Matthieu Chardon, Travis Harper, Richard Neal

  2. Micron Scale Mechanical Properties • Once structures enter microscale, laws of macro mechanics no longer dominate mechanical response • Samples approach size scale of grains and dislocations, also dominated by surface effects • Multimaterial interfaces, sharp corners in MEMS devices require in-situ characterization • Devices in market require a high amount of reliability, necessitating direct fatigue testing methods

  3. Advantages of In-Situ Testing • Model entire range of behavior • Differentiate elastic and plastic regimes • Understand more than ultimate tensile strength (UTS)

  4. Similar Works 1 3 1 =2 μm No testing results 2 1) Mechanical Measurements at the Micron and Nanometer Scales, Knauss, Huang 2) Microtensile Tests with the Aid of Probe Microscopy for the Study of MEMS Materials, Knauss, Chasiotis 3) MEMS Fatigue Testing to Study Nanoscale Response, Fisher, Labiossiere

  5. Testing stage • Polysilicon specimen • Integrated during fabrication • Pulled by mass • Actuators move mass when voltage applied • Force measured by capacitive sensor • Strain measured by DIC From Zhu et. al., 2003

  6. ANSYS Modeling of System The maximum load deliverable by the loading device is ~100 mN From Zhu et. al., 2003

  7. Polysilicon Sample 4μm 10μm From Prorok, et al. Vol 5, 2004.

  8. Integrated in Chip Yong’s Chip Chris’s Quarter

  9. Testing Setup Difficult to land the cantilever on the test specimen without repeatedly breaking tips

  10. Atomic Force Microscopy (AFM) • Benefits • Very fine resolution (~0.02nm) • Variable scanning size/rate • Risks • Noise sensitivity, drift • Constraints on sample size/mass From Espinosa, “Introduction to AFM and DPN”, ME395 Winter 2004

  11. AFM Resolution • Resolution • Dimension 3100: 512x512 pix • JEOL: 256x256 pix • Digital Image Correlation (DIC) can interpret change in position of a pixel by change in grayscale pixel strength (from 1=black to 255=white). • Ideally, DIC can understand a resolution of 1/255th of a pixel

  12. AFM Resolution • Scan size (say, 1.0 μm) corresponding to 512 pixels • DIC resolution: 1/255th of a pixel • Theoretical (maximum) displacement resolution (a) • If length of sample is 10m, theoretical resolution of strain is (b) (a) (b)

  13. AFM Imaging Types Amplitude Topography Polysilicon pad imaged using D3100 AFM

  14. AFM Imaging Types Amplitude Topography Polysilicon pad imaged using JEOL AFM

  15. AFM Problems • Adjustment of voltage, frequency for tip • Sensitivity to dust/scratches • Breakage of tip • Crash of tip into sample • Sensitivity of feedback control system

  16. Digital Image Correlation • No automatic compensation for drift • Correlation on stationary samples • Drift strain is only strain • Used to generate correction factor

  17. Digital Image Correlation (DIC) Example Illustrates DIC Capabilities Sample Prior to Deformation Error X-X Tensile Strain Y-Y Tensile Strain Shear Strain

  18. DIC Problems • Out-of-plane Deformation • Displacement Gradients • Scanning Noise

  19. DIC Resolution • Displacement resolution of DIC is 1/255pix, much smaller than the 0.512 pix minimum displacement in pixels for the polysilicon at failure. • AFM/DIC should be able to display 0.512/(1/255), or 130 images for the range of displacement to failure based on ideal resolution/largest scan area. *Note: actual resolution smaller than ideal, fewer images result. • Smaller scan areas will provide more images, and thus finer understanding of the change in strain over time.

  20. Digital Image Correlation (DIC) Sample DIC images from 10x10μm sample using D3100 AFM

  21. Digital Image Correlation (DIC) Sample DIC images from 10x10μm sample using JEOL 5200 AFM

  22. AFM Comparison The EPIC AFM, scanned in amplitude mode, yields the best results

  23. Experimental Design • Optimal Designs • Computer generated • Best with respect to a particular criterion • D-Optimal minimizes l(X’X)-1l • Places points at regions of greatest standard error

  24. Experimental Design Robust Design All relevant information obtained using less than half the required experiments in a full factorial study H0: μ1 = μ2 H1: μ1 ≠ μ2 α = P(type I error) = P(reject H0 l H0 true) β = P(type II error) = P(fail to reject H0 l H0 is false) Power = 1 - β

  25. Experimental Design Standard Order #19 Removed (Above 3.5) Outliers distort the analysis of variance Outlier when residuals +/- 3σ

  26. Experimental Results Significant Factors: A, B, AB R-Squared: .776

  27. Experimental Results

  28. In Conclusion… Optimal testing conditions for drift reduction: • JEOL 5200 AFM (Forced Feedback) • Amplitude Scan • Tapping Mode • High Scan Area Sample choice and scan rate effect drift rate very little

  29. In Conclusion… Optimized drift condition remains too large to distinguish polysilicon strains from error 1% Strain at failure for polysilicon – minimized drift remains 100% of experimental strain With current minimized strain values, brittle samples cannot be assessed

  30. Future Work Drift Effects Reduction Opportunities • Appraiser Variation in DIC Analysis • Environmental Effects • Electromechanical Noise • Temperature, Pressure, Humidity Variation • Feedback Mechanism - Consider Image Repeatability • Sample Ductility

  31. Thank You For Your Time Questions? In-Situ AFM Tensile Testing Group Chris Biedrzycki, Matthieu Chardon, Travis Harper, Richard Neal