1 / 8

E-166 Experiment

E-166 Experiment. E-166 is a demonstration of undulator-based polarized positron production for linear colliders. E-166 uses the 50 GeV FFTB beam in conjunction with 1 m-long, helical undulator (  = 2.4 mm, ID = 0.9 mm) to make 10-MeV polarized photons. These photons are converted in a

Download Presentation

E-166 Experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. E-166 Experiment E-166 is a demonstration of undulator-based polarized positron production for linear colliders. • E-166 uses the 50 GeV FFTB beam in conjunction with 1 m-long, helical undulator ( = 2.4 mm, ID = 0.9 mm) to make 10-MeV polarized photons. • These photons are converted in a ~ 0.5 rad. len. thick target into e+ (and e-) with ~ 50% polarization. • The polarization of the positrons and photons will be measured. • E-166 was approved in June 2003, for a main data run in 2005.

  2. E-166 Collaboration (47 Collaborators) (16 Institutions)

  3. E-166 Beam Measurements • Photon flux and polarization as a function of undulator K • (Pg ~ 75% for Eg > 5 MeV). • Positron flux and polarization vs. energy for K = 0.17, 0.5 r.l. of Ti • (Pe+ ~ 50%). • Positron flux and polarization for 0.1 r.l. and 0.25 r.l. Ti and 0.1, • 0.25, and 0.5 r.l. W targets. • Each measurement is expected to take about 20 minutes. • A relative polarization measurement of 5% is sufficient to • validate the polarized positron production processes. • The undulator will be pulsed in a random pattern of beam pulses • to permit continuous monitoring of undulator-off background levels.

  4. E-166 Undulator(built at Cornell U. by Mikhailichenko) Two helices wound on a 0.9-mm ID, 1-m-long hypodermic needle. 1.4 kA pulses, ~ 5 μs long provide field of ~ 1 T on axis,  k ~ 0.15.

  5. Positron Spectrometer(magnets built at Princeton)

  6. Aerogel Cerenkov Counters(built at Princeton) Two Cerenkov counters with aerogel of index n = 1.0095 are now in the FFTB tunnel. Index measured with a Michaelson interferometer.

  7. Preliminary Results from Runsof E-166 in June and Sept 2005 Linac ran at 46.6 GeV, rather than 50 GeV,  max. positron energy only 8 MeV. Positron asymmetries observed of order 1%. Preliminary calculation of analyzing power implies that positron polarizations of up to 80-90% were observed.

  8. Implications The use of undulator-based production of positrons was accepted as the ILC baseline at SNOWMASS’05. The use of a helical undulator for production of polarized positrons is the recommended option. This option must now be established as cost effective.

More Related