labthroughput - PowerPoint PPT Presentation


  • 68 Views
  • Uploaded on

To advance to the next slide click on any blank area of the slide To jump to a topic or module of interest click on the box with the module/topic Click on the back arrow(s) to return to menu . www.labthroughput.com. 845-425-9711 845-270-8449. 1.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' labthroughput' - sirius


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

To advance to the next slide click on any blank area of the slide

  • To jump to a topic or module of interest click on the box with the module/topic
  • Click on the back arrow(s) to return to menu

www.labthroughput.com

845-425-9711

845-270-8449

1

slide2
LTP is a software company dedicated to improving workflow efficiency and productivity in the clinical laboratory

LTP Products:

  • Automate results verification, review, follow-up actions and disposition for Hematology, Coagulation, Chemistry & Immunochemistry, and Urinalysis
  • Optimize by monitoring workflow in real-time and retrospectively
  • Provide real-time Quality Control compliance
  • Allow you to expand your hematology services to automate BAL and other fluid analyses

2

slide3
What LTPdoes
  • How LTP works
    • How the LTPreview-criteria optimization process works
  • How LTPreduces operating costs/improves profitability
  • What LTP products are available

3

slide4

LabThroughPut™

GlobaLab Efficiency Products

LTPACHIEVER™

LTPOPTIMIZER™

LTPQC SENTINEL™

LTPBAL/HEMATOLOGY™

LTPMIDDLEWARE™ SYSTEM Configuration

4

slide5

LTPGlobaLab ™ Products

LTPACHIEVER™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

LTPOPTIMIZER™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

LTPQC SENTINEL™

LTPBAL/HEMATOLOGY™

5

slide6

LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULES
    • SYSTEM SETUP and SECURITY
    • INSTRUMENT MANAGER
    • EVALUATOR
    • PROCESSOR
    • ENDSHIFT
    • MONITOR

6

slide7

LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULE Functionality
    • SYSTEM SETUP and SECURITY
      • Provides for Defining: access level heirarchy, user/password control, parameters, review rules, edit/display order, and Shift report content and distribution
    • INSTRUMENT MANAGER
      • Controls data transmission: receives data from analyzers and LIS, transmits to analyzers and LIS; monitors connectivity
    • EVALUATOR
      • Evaluates results by autoverification of User Rules: assigns samples to worklists and locates them for tech data entry screens, provides disposition of results

7

slide8

LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULE Functionality
    • PROCESSOR
      • Provides for all operations: label printing, data entry/modification, Supervisory review/approval, tracks current status and audit trail of results, and provides for archive and retrieval
    • ENDSHIFT
      • Closes Instrument Manager at defined end of shift times; creates, distributes and saves End of Shift Reports
    • MONITOR
      • Checks Instrument Manager and Evaluator continually, in the background, for proper functioning of data entry/modification

8

slide9

LTPACHIEVER™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER is a complete results processing system.
    • Auto-verifies analyzer results
    • Issues follow-up worklists along with procedures
    • Provides data entry screens for necessary results changes
      • On-screen diffpad for microscopic observation entry
    • Determines final disposition
    • Transmits results to the host computer system for release
    • Stores every state of every specimen record in a database; maintains audit trail
    • Self-monitors and diagnoses system operations
    • Produces activity and productivity reports

9

slide10

LTPACHIEVER™

SYSTEM SETUP & SECURITY MODULE

Functions

  • User-definable setup of:
    • Review Rules
    • Instrument and Lab-defined parameters to receive
    • Parameters to be displayed/edited by techs, including display order
    • Parameters to be transmitted to LIS
    • User names/passwords
    • Access levels to system functions
    • Shift Report contents and E-mail recipients

Features

  • User defines which parameter value fields can be edited by tech, and under which circumstances
  • Parameter field background colors are user-definable for clarity

10

slide13

LTPACHIEVER™

INSTRUMENT MANAGER MODULE

Functions

  • Receives data from analyzers and LIS
  • Transmits data to analyzers and LIS

Features

  • Analyzer/Instrument Manager connectivity diagnostics
  • Host/Instrument Manager connectivity diagnostics
    • Issue connectivity alerts audibly, via E-mail and via text messaging

13

slide15

LTPACHIEVER™

EVALUATOR MODULE

EVALUATOR Features:

  • Follow-up procedure worklists are created based on User criteria
  • Special follow-up options include automatic replacement of instrument parameter values by values obtained on the instrument by other means; e.g. WIC/WOC or analyte dilution results
  • Audit trail maintenance:
    • Database archival of up to 1,000,000 specimen records
    • Every state of every record is stored in a database
    • All changes made to results are recorded/audit trailed
      • WHO, WHEN and WHY any change was made
      • WHAT Method used to make the change
  • Final disposition state for each specimen record is recorded

15

slide17

LTPACHIEVER™

PROCESSOR MODULE

PROCESSOR Features:

  • Open architecture supports simultaneous analysis of any combination of:
    • Multiple Species
    • Analyzer manufacturers/models
    • Body fluid types
  • Analyzes specimen results on-line in real-time, using your verification criteria.
    • Special verification options include:
      • Activation/de-activation of individual rules within a set
      • Advanced delta-check techniques
      • Color coding for: Rerun, Diff needed, Spun Hct
      • Tech ID, data entry, results and workstation tracked

17

slide18

LTPACHIEVER™

ENDSHIFT MODULE

  • Endshift Features
    • The Endshift process is entirely automatic
      • Stops Instrument Manager and Evaluator automatically
      • Restarts Instrument Manager and Evaluator automatically when Endshift process is completed
    • Endshift Report contents and recipients are User definable
    • Endshift will not occur if LTPdetects that specimens are still being processed
    • Endshift times can vary by day and shift
    • Multiple Endshifts per day can be programmed
    • Number of Endshift retries and retry intervals are user definable

18

slide19

LTPACHIEVER™

MONITOR MODULE

MONITOR Features:

  • Monitors Evaluator and Instrument Manager for functional compliance
  • Starts automatically at beginning of shift and runs in the background
  • Restarts application(s) if fault is detected
  • Maintains an all inclusive event Log

19

slide21

LTPOPTIMIZER™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER ™ helps you optimize specimen results throughput in the laboratory
    • Uses your results-verification criteria to measure the overall specimen-result review rate in the laboratory
    • Determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure; eg. analyzer reruns or manual differentials
    • Allows readjustment of criteria and re-analyzes the results to optimize criteria and improve throughput
    • Provides database query capability

21

slide22

LTPOPTIMIZER™

WHAT LTP OPTIMIZER DOES

OPTIMIZER Features

  • LTP OPTIMIZER™ provides review rates:
    • For all specimens combined
    • Based on individual review criterion
    • Based on instrument, for multiple-instrument systems
    • Based on instrument model, for labs using more than one analyzer model (open architecture)
    • Based on body fluid type, for labs running whole blood samples and other body fluids
    • Based on species, for veterinary labs

22

slide23

LTPOPTIMIZER™

LTPOPTIMIZER QUERY MODULE

Functions

  • Queries either the live or archival database for performance parameters
    • Productivity summary by analyzer or by operator
    • # of specimens analyzed over time interval per species, analyzer, tech, body fluid type, etc.
    • # of specimens work-listed per rule, per species, per analyzer, per body fluid type
    • # of follow-up actions per rule, per species, per analyzer, per body fluid type

Features

  • Analysis of archived results based on rules applied live
  • Analysis of archived results using modified review rules

23

slide24

LTPACHIEVER/HEMATOLOGY™

WHAT LTPACHIEVER/HEMATOLOGY™ DOES

  • LTPACHIEVER/HEMATOLOGY is a complete results processing system.
    • Auto-verifies hematology analyzer results
    • Issues follow-up worklists along with procedures
    • Provides data entry screens for necessary results changes
      • On-screen diffpad
    • Determines final disposition
    • Transmits results to the host computer system for release
    • Stores every state of every specimen record in a database

24

slide25

LTPHEMATOLOGY™

HOW the LTPreview-criteria optimization process works

  • SETUP REVIEW CRITERIA & SECURITY
  • ENTER (AND EDIT) REVIEW CRITERIA
    • REVIEW-CRITERIA BATCH SCREEN
    • REVIEW-CRITERION EDITOR
  • Review specimen record data
  • Examine results of specimen record review
  • Edit review criteria and re-analyze data

25

slide26

LTPHEMATOLOGY™

SYSTEM SETUP & SECURITY MODULE

Functions

  • User-definable setup of:
    • Review Rules
    • Instrument and Lab-defined parameters to receive
    • Parameters to be displayed/edited by techs, including display order
    • Parameters to be transmitted to LIS
    • User names/passwords
    • Access levels to system functions
    • Shift Report contents and E-mail recipients

Features

  • User defines which parameter value fields can be edited by tech, and under which circumstances
  • Parameter field background colors are user-definable for clarity

26

slide30

LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

  • Review criteria are grouped. A set (“batch”) of criteria is entered for each combination of instrument type/body fluid type/species (see slide 12)
  • Multiple sets can be active simultaneously, but only one set at a time can be active for each combination of instrument type/body fluid type/species
  • Sets and individual criteria can be de-activated
  • Specimens not matching any set are flagged
  • Sets can be printed

30

slide31

LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

Review criteria include

  • Limits
    • Parameter values
    • Products of 2 parameter values
    • Ratios of 2 parameter values
    • Sums of 2 parameter values
    • Differences of 2 parameter values
    • % differences of 2 parameter values
  • Morphology Flags
    • Presence
    • Severity
  • System Operational Alerts
    • Presence
    • Severity

(CONTINUED ON NEXT SLIDE)

31

slide32

LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

Review criteria include:

  • Demographics
    • Age
    • Gender
  • Blanked results
  • Delta Checks(Apply to any combination of parameters listed above under limits)
    • Difference
    • Absolute difference
    • % difference
    • Absolute % difference
    • Rate of delta for any of the above, by:
      • Day, Week or Month

32

slide33

LTPHEMATOLOGY REVIEW CRITERIA BATCH SCREEN

INSTRUMENT TYPE

SPECIES

SPECIMEN TYPE

33

slide34

LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

CRITERION

ACTION

PARAMETER THAT IS RE-ANALYZED

AFFECTED PARAMETER(S)

FORMULAS

34

slide41

LTPHEMATOLOGY™

EVALUATOR MODULE

EVALUATOR Features

  • Follow-up procedure worklists are created based on your criteria
  • Special follow-up options include automatic replacement of instrument parameter values by values obtained on the instrument by other means; e.g. WIC/WOC
  • Audit trail maintenance:
    • Database archival of up to 500,000 specimen records
    • Every state of every record is stored in a database
    • All changes made to results are recorded/audit trailed
      • WHO, WHEN and WHY any change was made
      • WHAT Method used to make the change
  • Final disposition state for each specimen record is recorded

41

slide43

LTPHEMATOLOGY™

PROCESSOR MODULE

Functions

  • Provides for all operations: label printing, data entry/modification, Supervisory review/approval, tracks current status and audit trail of results, and provides for archive and retrieval

Features

  • Auto-verifies analyzer results
  • Issues follow-up worklists along with procedures
  • Provides data entry screens for necessary results changes
    • On-screen diffpad or microscopic observation entry
  • Determines final disposition
  • Stores every state of every specimen record in a database

43

slide44

LTPHEMATOLOGY™

PROCESSOR MODULE

PROCESSOR Features

  • Open architecture supports any combination of:
    • Analyzer manufacturers/models
    • Body fluid types
    • Species
  • Analyzes specimen results on-line in real-time, using your verification criteria.
    • Special verification options include:
      • Activation/de-activation of individual rules within a set
      • Advanced delta-check techniques
      • Color coding for: Rerun, Diff needed, Spun Hct
      • Tech ID, data entry, results and workstation tracked

44

slide50

LTPHEMATOLOGY™

ENDSHIFT MODULE

  • Functions
    • Closes Instrument Manager and Evaluator at predetermined times during the day
    • Creates shift reports that include
      • Overall workshift output
      • Technologist productivity
      • Analyzer outputs by table and graphical display
      • Review rules analysis
    • Saves reports on system server and emails reports to designated addresses

50

slide51

LTPHEMATOLOGY™

ENDSHIFT MODULE

  • Features
    • Endshift times can vary by day and shift
    • Multiple Endshifts per day can be programmed
    • Report contents and recipients are user definable
    • The Endshift process is entirely automatic
      • Stops Instrument Manager and Evaluator automatically
      • Restarts Instrument Manager and Evaluator automatically when Endshift process is completed
    • Endshift will not occur if LTPdetects that specimens are still being processed
    • Number of Endshift retries and retry intervals are user definable

51

slide52

LTPENDSHIFT REPORTED RESULTS

YOUR LAB

ADDRESS, ETC

slide53

LTPENDSHIFT PENDING RESULTS

YOUR LAB

ADDRESS, ETC

slide59

LTPOPTIMIZER/HEMATOLOGY™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/HEMATOLOGYTM is software that helps you optimize specimen results throughput in the laboratory
    • It uses your results-verification criteria to measure the overall specimen-result review rate in the laboratory
    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or manual differentials
    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

59

slide60

LTPOPTIMIZER/HEMATOLOGY™

WHAT LTPOPTIMIZER DOES

Features

  • LTPOPTIMIZER/HEMATOLOGYTM provides review rates:
    • For all specimens combined
    • Based on individual review criterion
    • Based on instrument, for multiple-instrument systems
    • Based on instrument model, for labs using more than one analyzer model (open architecture)
    • Based on body fluid type, for labs running whole blood samples and other body fluids
    • Based on species, for veterinary labs

60

slide61

LTPOPTIMIZER/HEMATOLOGY™

LTPOPTIMIZER QUERY MODULE

Functions

  • Queries either the live or archival database for performance parameters
    • Productivity summary by analyzer or by operator
    • # of specimens analyzed over time interval per species, analyzer, tech, body fluid type, etc.
    • # of specimens work-listed per rule, per species, per analyzer, per body fluid type
    • # of follow-up actions per rule, per species, per analyzer, per body fluid type

Features

  • Analysis of archived results based on rules applied live
  • Analysis of archived results using modified review rules

61

slide64

LTPHEMATOLOGY™

HOW LTPREDUCES OPERATING COSTS

  • Redeployment of skilled results-review staff
  • Eliminates erroneous specimen record handling decisions
  • Optimizes review criteria/follow-up processes
  • Provides audit trail

64

slide65

LTPHEMATOLOGY™

Hematology Products

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

LTPRAT BAL™

LTPGUINEA PIG BAL™

LTPMONKEY BAL™

LTPQCSENTINEL/HEMATOLOGY™

65

slide66

LTPBAL/HEMATOLOGY™

WHAT LTP BAL/HEMATOLOGY DOES

  • LTPBAL/HEMATOLOGY is software that automates BAL fluid specimen analyses on ADVIA 120/2120
    • No sample preparation
    • Reduces sample analysis time to approximately 1 minute/sample
    • Reports results in XL spreadsheet format
      • WBC
      • #,%Neuts
      • #,%Eos
      • #,% Mononuclear cells
    • Does NOT affect or alter ADVIA 120/2120 software

66

slide67

LTPBAL/HEMATOLOGY™

WHAT LTP BAL/HEMATOLOGY DOES

  • Product Features
    • WBC count @20 cells/µL
    • Differential @50 cells/µL
    • No RBC interference in WBC analysis
    • Species supported
      • Mouse allergic model and smoke inhalation model
      • Rat allergic model and smoke inhalation model
      • Cynomolgus monkey allergic model
      • Guinea pig allergic model
    • Does NOT affect or alter ADVIA 120/2120 software

67

slide68

Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Whole Blood

Comparative Results

Mouse BAL

Eos Model

Whole Blood Archetype

MNC

Lipid

Mouse BAL

Eos Model

BAL Archetype

PMN

MN

Eos

Lymphs

68

slide69

Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

EOS + Neuts Model

Whole Blood Archetype

Comparative Results

Mouse BAL

Eos + Neuts Model

BAL Archetype

69

slide70

Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Negative Control

Whole Blood Archetype

Comparative Results

Mouse BAL

Smoke Inhalation

Negative Control

BAL Archetype

70

slide71

Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Positive CTRL

Whole Blood Archetype

Comparative Results

Debris

Mouse BAL

Smoke Inhalation

Positive CTRL

BAL Archetype

71

slide72

Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Drug-Treated

Whole Blood Archetype

Comparative Results

Mouse BAL

Smoke Inhalation

Drug-Treated

BAL Archetype

72

slide73

Rat

LTPBAL/HEMATOLOGY™

Whole Blood

LTPRAT BAL™

BAL

Allergic Model

Negative Control

Whole Blood Archetype

Comparative Results

MNC

BAL

Allergic Model

Negative Control

BAL Archetype

Debris

MN

Eos

PMN

Neuts

Lymphs

73

slide74

Rat

LTPBAL/HEMATOLOGY™

LTPRAT BAL™

Rat BAL

Allergic Model

Positive Control

Whole Blood Archetype

Comparative Results

Rat BAL

Allergic Model

Positive Control

BAL Archetype

74

slide75

Rat

LTPBAL/HEMATOLOGY™

LTPRAT BAL™

Rat BAL

Allergic Model

Drug-Treated

Whole Blood Archetype

Comparative Results

Rat BAL

Allergic Model

Drug-Treated

BAL Archetype

75

slide76

LTPBAL/HEMATOLOGY™

Cynomolgus

Monkey

Whole Blood

LTPMONKEY BAL™

Cyno Monkey BAL

Allergic Model

Negative Control

Whole Blood Archetype

Comparative Results

Cyno Monkey

Allergic Model

Negative Control

BAL Archetype

Debris

MNC

MN

PMN

Eos

Neuts

Lymphs

76

slide77

LTPBAL/HEMATOLOGY™

Cynomolgus

Monkey

LTPMONKEY BAL™

Cyno Monkey BAL

Allergic Model

Positive Control

Whole Blood Archetype

Comparative Results

Cyno Monkey BAL

Allergic Model

Positive Control

BAL Archetype

77

slide78

Guinea Pig

LTPBAL/HEMATOLOGY™

Whole Blood

LTPGUINEA PIG BAL™

Comparative Results

Guinea Pig BALAllergic Model

Positive Control

Whole Blood Archetype

Guinea Pig BALAllergic Model

Positive Control

BAL Archetype

NMC

Debris

Eos

Neuts

Debris

78

slide79

LTPBAL/HEMATOLOGY™

HOW LTPREDUCES OPERATING COSTS

  • Automate time intensive manual process
  • Provide standardized objective criteria
  • Reduces specimen analysis time
  • Allows redeployment of skilled staff

79

slide80

LTPCOAGULATION™

Coagulation Products

LTPACHIEVER/COAGULATION™

LTPOPTIMIZER/COAGULATION™

LTPQCSENTINEL/COAGULATION™

80

slide81

LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/COAGULATION is a complete results processing system.
    • Auto-verifies coagulation analyzer results
    • Issues follow-up worklists along with procedures
    • Provides data entry screens for necessary results changes
    • Determines final disposition
    • Transmits results to the host computer system for release
    • Stores every state of every specimen record in a database

81

slide82

LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

Features

  • Open architecture supports any combination of:
    • Analyzer manufacturers/models
    • Body fluid types
    • Species
  • Analyzes specimen results on-line in real-time, using your verification criteria.
    • Special verification options include:
      • Activation/de-activation of individual rules within a set
      • Advanced delta-check techniques
      • Rerun-only criteria

82

slide83

LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria
  • Audit trail maintenance:
    • Database archival of up to 500,000 specimen records
    • Every state of every record is stored in a database
    • All changes made to results are recorded/audit trailed
      • WHO, WHEN and WHY any change was made
      • WHAT Method used to make the change
  • Final disposition state for each specimen record is recorded

83

slide84

LTPOPTIMIZER/COAGULATION™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/COAGULATION ™ is software that helps you optimize specimen results throughput in the laboratory
    • It uses your coagulation results-verification criteria to measure the overall specimen-result review rate in the laboratory
    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or prolonged clotting times
    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

84

slide85

LTPOPTIMIZER/COAGULATION™

WHAT LTPOPTIMIZER DOES

Features

  • LTPOPTIMIZER/COAGULATION ™ provides review rates:
    • For all specimens combined
    • Based on individual review criterion
    • Based on instrument, for multiple-instrument systems
    • Based on instrument model, for labs using more than one analyzer model (open architecture)
    • Based on body fluid type, for labs running whole blood samples and other body fluids
    • Based on species, for veterinary labs

85

slide86

LTPCHEMISTRY™

Chemistry Products

LTPACHIEVER/CHEMISTRY™

LTPOPTIMIZER/CHEMISTRY™

LTPQCSENTINEL/CHEMISTRY™

86

slide87

LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/CHEMISTRY is a complete results processing system.
    • Auto-verifies chemistry analyzer results
    • Issues follow-up worklists along with procedures
    • Provides data entry screens for necessary results changes
    • Determines final disposition
    • Transmits results to the host computer system for release
    • Stores every state of every specimen record in a database

87

slide88

LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

Features

  • Open architecture supports any combination of:
    • Analyzer manufacturers/models
    • Body fluid types
    • Species
  • Analyzes specimen results on-line in real-time, using your verification criteria.
    • Special verification options include:
      • Activation/de-activation of individual rules within a set
      • Advanced delta-check techniques
      • Rerun-only criteria

88

slide89

LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria
  • Audit trail maintenance:
    • Database archival of up to 500,000 specimen records
    • Every state of every record is stored in a database
    • All changes made to results are recorded/audit trailed
      • WHO, WHEN and WHY any change was made
      • WHAT Method used to make the change
  • Final disposition state for each specimen record is recorded

89

slide90

LTPOPTIMIZER/CHEMISTRY™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/CHEMISTRY ™ is software that helps you optimize specimen results throughput in the laboratory
    • It uses your chemistry results-verification criteria to measure the overall specimen-result review rate in the laboratory
    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns, below detection limit or dilutions needed.
    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

90

slide91

LTPOPTIMIZER/CHEMISTRY™

WHAT LTP OPTIMIZER DOES

Features

  • LTP OPTIMIZER /CHEMISTRY ™ provides review rates:
    • For all specimens and parameters combined
    • Based on your individual review criterion
    • Based on instrument, for multiple-instrument systems
    • Based on instrument model, for labs using more than one analyzer model (open architecture)
    • Based on body fluid type, for labs running whole blood samples and other body fluids
    • Based on species, for veterinary labs

91

slide92

LTPURINALYSIS™

Urinalysis Products

LTPACHIEVER/URINALYSIS™

LTPOPTIMIZER/URINALYSIS™

LTPQCSENTINEL/URINALYSIS™

92

slide93

LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/URINALYSIS is a complete results processing system.
    • Auto-verifies urinalysis analyzer results
    • Issues follow-up worklists along with procedures
    • Provides data entry screens for necessary results changes
      • On-screen microscopic observation data entry pad
    • Determines final disposition
    • Transmits results to the host computer system for release
    • Stores every state of every specimen record in a database

93

slide94

LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

Features:

  • Open architecture supports any combination of:
    • Analyzer manufacturers/models
    • Body fluid types
    • Species
  • Analyzes specimen results on-line in real-time, using your verification criteria.
    • Special verification options include:
      • Activation/de-activation of individual rules within a set
      • Advanced delta-check techniques
      • Rerun-only criteria

94

slide95

LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria
  • Audit trail maintenance:
    • Database archival of up to 500,000 specimen records
    • Every state of every record is stored in a database
    • All changes made to results are recorded/audit trailed
      • WHO, WHEN and WHY any change was made
      • WHAT Method used to make the change
  • Final disposition state for each specimen record is recorded

95

slide96

LTPOPTIMIZER/URINALYSIS™

WHAT LTPOPTIMIZER DOES

  • LTP OPTIMIZER/URINALYSIS™ is software that helps you optimize specimen results throughput in the laboratory
    • It uses your urinalysis results-verification criteria to measure the overall specimen-result review rate in the laboratory
    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or microscopic element types (eg. crystals)
    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

96

slide97

LTPOPTIMIZER/URINALYSIS™

WHAT LTP OPTIMIZERDOES

  • Features
      • provides review rates:
        • For all specimens combined
        • Based on your individual review criterion
        • Based on instrument, for multiple-instrument systems
        • Based on instrument model, for labs using more than one analyzer model (open architecture)
        • Based on body fluid type, for labs running whole blood samples and other body fluids
        • Based on species, for veterinary labs

97

slide98

LabThroughPut™ Products

Quality Control Module

LTPQCSENTINEL™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

QC SENTINELMODULE

IS PRESENTLY UNDER DEVELOPMENT

98

slide99

General LIS Configuration

WITHOUTLTPMIDDLEWARE

  • An LIS has multiple connections and interfaces, in multiple categories
    • Analyzer – LIS
      • A different interface for each analyzer brand
    • Numerous Data Entry Workstations
    • Printers

99

slide100

General LIS Configuration

SLIDES

SLIDES

SLIDES

SLIDES

SLIDES

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

BC PRT

A1

A2

A3

SLIDES = slide-making workstations

DIFFS = Diff-reader workstations

PRT = Printer

BC PRT = Barcode printer

SUP WS1-3 = Supervisor workstations

InstMgr12 = Instrument Manager workstation

External Storage = Terabyte drive

A1-A14 = ADVIA 120 Analyzers

CD1-CD4 = CellDyn 3500 Analyzers

Notes:

1. Server-to-Server connection by dedicated NICs.

2. InstMgr-to-Analyzer and InstMgr-to-ANTRIM connections via serial ports.

3. Analyzer-to-ANTRIM failsafe direct serial port connections not shown.

4. Circled numbers are hub connection #s

PRT

A4

1-6

Sup

WS1

8-15

A5

A6

ANTRIM

A7

Sup

WS2

A8

A9

Sup

WS3

A10

A11

A12

A13

A14

Main

Server

Backup

Server

CD1

CD2

CD3

External

Storage

CD4

slide101

LTPMIDDLEWARE™ SYSTEM Configuration

WITH LTPMIDDLEWARE

  • The LIS has only a single connection to LTPMiddleware
  • LTPMiddleware is responsible for interfacing to the various categories of devices
  • LTPMiddleware unburdens the LIS of interfacing with multiple laboratory devices, each with its own interface specification
  • Bidirectional LTPMiddleware – LIS interfaces follow standards such as ASTM1381/1395 or HL7

101

slide102

LTPMiddleware System Configuration

SLIDES

SLIDES

SLIDES

SLIDES

SLIDES

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

BC PRT

A1

1-6

DSL

A2

8-15

7

A3

SLIDES = slide-making workstations

DIFFS = Diff-reader workstations

PRT = Printer

BC PRT = Barcode printer

SUP WS1-3 = Supervisor workstations

InstMgr12 = Instrument Manager workstation

External Storage = Terabyte drive

A1-A14 = ADVIA 120 Analyzers

CD1-CD4 = CellDyn 3500 Analyzers

Notes:

1. Server-to-Server connection by dedicated NICs.

2. InstMgr-to-Analyzer and InstMgr-to-ANTRIM connections via serial ports.

3. Analyzer-to-ANTRIM failsafe direct serial port connections not shown.

4. Circled numbers are hub connection #s

PRT

Hub

A4

Sup

WS1

A5

16-19

20

A6

21

22

LTP

Inst

Mgr

A7

Sup

WS2

A8

Main

Server

Backup

Server

A9

Sup

WS3

A10

A11

External

Storage

A12

A13

ANTRIM

A14

CD1

CD2

CD3

CD4

slide103

LTPMIDDLEWARE™ SYSTEM

LTPSystem Backup

  • LTPMIDDLEWAREautomatically copies the system environment, including applications and DB, to External Media daily
  • LTPMIDDLEWARE also continually replicates the environment to a Backup Server
  • The LTPBackup Server automatically takes over if the Main Server fails

103

slide104

LTPMIDDLEWARE™ SYSTEM

LTPSystem Technical Support

  • LTPTECHNICAL SUPPORT
  • Available whenever the laboratory is in operation
  • Lab personnel can call a telephone number and speak directly with support staff
  • Support staff have remote access to the middleware system which enables them to quickly diagnose a problem and to make any necessary changes

104

slide105

Thank You

for your attention.

www.labthroughput.com

845-425-9711