To advance to the next slide
Download
1 / 105

labthroughput - PowerPoint PPT Presentation


  • 68 Views
  • Uploaded on

To advance to the next slide click on any blank area of the slide To jump to a topic or module of interest click on the box with the module/topic Click on the back arrow(s) to return to menu . www.labthroughput.com. 845-425-9711 845-270-8449. 1.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' labthroughput' - sirius


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

  • To advance to the next slide click on any blank area of the slide

  • To jump to a topic or module of interest click on the box with the module/topic

  • Click on the back arrow(s) to return to menu

www.labthroughput.com

845-425-9711

845-270-8449

1


LTP is a software company dedicated to improving workflow efficiency and productivity in the clinical laboratory

LTP Products:

  • Automate results verification, review, follow-up actions and disposition for Hematology, Coagulation, Chemistry & Immunochemistry, and Urinalysis

  • Optimize by monitoring workflow in real-time and retrospectively

  • Provide real-time Quality Control compliance

  • Allow you to expand your hematology services to automate BAL and other fluid analyses

2


  • What LTPdoes

  • How LTP works

    • How the LTPreview-criteria optimization process works

  • How LTPreduces operating costs/improves profitability

  • What LTP products are available

3


LabThroughPut™

GlobaLab Efficiency Products

LTPACHIEVER™

LTPOPTIMIZER™

LTPQC SENTINEL™

LTPBAL/HEMATOLOGY™

LTPMIDDLEWARE™ SYSTEM Configuration

4


LTPGlobaLab ™ Products

LTPACHIEVER™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

LTPOPTIMIZER™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

LTPQC SENTINEL™

LTPBAL/HEMATOLOGY™

5


LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULES

    • SYSTEM SETUP and SECURITY

    • INSTRUMENT MANAGER

    • EVALUATOR

    • PROCESSOR

    • ENDSHIFT

    • MONITOR

6


LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULE Functionality

    • SYSTEM SETUP and SECURITY

      • Provides for Defining: access level heirarchy, user/password control, parameters, review rules, edit/display order, and Shift report content and distribution

    • INSTRUMENT MANAGER

      • Controls data transmission: receives data from analyzers and LIS, transmits to analyzers and LIS; monitors connectivity

    • EVALUATOR

      • Evaluates results by autoverification of User Rules: assigns samples to worklists and locates them for tech data entry screens, provides disposition of results

7


LTPACHIEVER™

LTPACHIEVER is a system that optimizes results processing in the laboratory and improves productivity

  • ACHIEVER MODULE Functionality

    • PROCESSOR

      • Provides for all operations: label printing, data entry/modification, Supervisory review/approval, tracks current status and audit trail of results, and provides for archive and retrieval

    • ENDSHIFT

      • Closes Instrument Manager at defined end of shift times; creates, distributes and saves End of Shift Reports

    • MONITOR

      • Checks Instrument Manager and Evaluator continually, in the background, for proper functioning of data entry/modification

8


LTPACHIEVER™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER is a complete results processing system.

    • Auto-verifies analyzer results

    • Issues follow-up worklists along with procedures

    • Provides data entry screens for necessary results changes

      • On-screen diffpad for microscopic observation entry

    • Determines final disposition

    • Transmits results to the host computer system for release

    • Stores every state of every specimen record in a database; maintains audit trail

    • Self-monitors and diagnoses system operations

    • Produces activity and productivity reports

9


LTPACHIEVER™

SYSTEM SETUP & SECURITY MODULE

Functions

  • User-definable setup of:

    • Review Rules

    • Instrument and Lab-defined parameters to receive

    • Parameters to be displayed/edited by techs, including display order

    • Parameters to be transmitted to LIS

    • User names/passwords

    • Access levels to system functions

    • Shift Report contents and E-mail recipients

      Features

  • User defines which parameter value fields can be edited by tech, and under which circumstances

  • Parameter field background colors are user-definable for clarity

10


LTPSYSTEM SETUP SCREENS


LTPSYSTEM SETUP REVIEW CRITERIA REPORT


LTPACHIEVER™

INSTRUMENT MANAGER MODULE

Functions

  • Receives data from analyzers and LIS

  • Transmits data to analyzers and LIS

    Features

  • Analyzer/Instrument Manager connectivity diagnostics

  • Host/Instrument Manager connectivity diagnostics

    • Issue connectivity alerts audibly, via E-mail and via text messaging

13


LTPINSTRUMENT MANAGER SCREEN


LTPACHIEVER™

EVALUATOR MODULE

EVALUATOR Features:

  • Follow-up procedure worklists are created based on User criteria

  • Special follow-up options include automatic replacement of instrument parameter values by values obtained on the instrument by other means; e.g. WIC/WOC or analyte dilution results

  • Audit trail maintenance:

    • Database archival of up to 1,000,000 specimen records

    • Every state of every record is stored in a database

    • All changes made to results are recorded/audit trailed

      • WHO, WHEN and WHY any change was made

      • WHAT Method used to make the change

  • Final disposition state for each specimen record is recorded

15


LTPEVALUATOR MODULE SCREEN


LTPACHIEVER™

PROCESSOR MODULE

PROCESSOR Features:

  • Open architecture supports simultaneous analysis of any combination of:

    • Multiple Species

    • Analyzer manufacturers/models

    • Body fluid types

  • Analyzes specimen results on-line in real-time, using your verification criteria.

    • Special verification options include:

      • Activation/de-activation of individual rules within a set

      • Advanced delta-check techniques

      • Color coding for: Rerun, Diff needed, Spun Hct

      • Tech ID, data entry, results and workstation tracked

17


LTPACHIEVER™

ENDSHIFT MODULE

  • Endshift Features

    • The Endshift process is entirely automatic

      • Stops Instrument Manager and Evaluator automatically

      • Restarts Instrument Manager and Evaluator automatically when Endshift process is completed

    • Endshift Report contents and recipients are User definable

    • Endshift will not occur if LTPdetects that specimens are still being processed

    • Endshift times can vary by day and shift

    • Multiple Endshifts per day can be programmed

    • Number of Endshift retries and retry intervals are user definable

18


LTPACHIEVER™

MONITOR MODULE

MONITOR Features:

  • Monitors Evaluator and Instrument Manager for functional compliance

  • Starts automatically at beginning of shift and runs in the background

  • Restarts application(s) if fault is detected

  • Maintains an all inclusive event Log

19


LTPMONITOR MODULE SCREEN


LTPOPTIMIZER™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER ™ helps you optimize specimen results throughput in the laboratory

    • Uses your results-verification criteria to measure the overall specimen-result review rate in the laboratory

    • Determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure; eg. analyzer reruns or manual differentials

    • Allows readjustment of criteria and re-analyzes the results to optimize criteria and improve throughput

    • Provides database query capability

21


LTPOPTIMIZER™

WHAT LTP OPTIMIZER DOES

OPTIMIZER Features

  • LTP OPTIMIZER™ provides review rates:

    • For all specimens combined

    • Based on individual review criterion

    • Based on instrument, for multiple-instrument systems

    • Based on instrument model, for labs using more than one analyzer model (open architecture)

    • Based on body fluid type, for labs running whole blood samples and other body fluids

    • Based on species, for veterinary labs

22


LTPOPTIMIZER™

LTPOPTIMIZER QUERY MODULE

Functions

  • Queries either the live or archival database for performance parameters

    • Productivity summary by analyzer or by operator

    • # of specimens analyzed over time interval per species, analyzer, tech, body fluid type, etc.

    • # of specimens work-listed per rule, per species, per analyzer, per body fluid type

    • # of follow-up actions per rule, per species, per analyzer, per body fluid type

      Features

  • Analysis of archived results based on rules applied live

  • Analysis of archived results using modified review rules

23


LTPACHIEVER/HEMATOLOGY™

WHAT LTPACHIEVER/HEMATOLOGY™ DOES

  • LTPACHIEVER/HEMATOLOGY is a complete results processing system.

    • Auto-verifies hematology analyzer results

    • Issues follow-up worklists along with procedures

    • Provides data entry screens for necessary results changes

      • On-screen diffpad

    • Determines final disposition

    • Transmits results to the host computer system for release

    • Stores every state of every specimen record in a database

24


LTPHEMATOLOGY™

HOW the LTPreview-criteria optimization process works

  • SETUP REVIEW CRITERIA & SECURITY

  • ENTER (AND EDIT) REVIEW CRITERIA

    • REVIEW-CRITERIA BATCH SCREEN

    • REVIEW-CRITERION EDITOR

  • Review specimen record data

  • Examine results of specimen record review

  • Edit review criteria and re-analyze data

25


LTPHEMATOLOGY™

SYSTEM SETUP & SECURITY MODULE

Functions

  • User-definable setup of:

    • Review Rules

    • Instrument and Lab-defined parameters to receive

    • Parameters to be displayed/edited by techs, including display order

    • Parameters to be transmitted to LIS

    • User names/passwords

    • Access levels to system functions

    • Shift Report contents and E-mail recipients

      Features

  • User defines which parameter value fields can be edited by tech, and under which circumstances

  • Parameter field background colors are user-definable for clarity

26


LTPHEMATOLOGY SYSTEM SETUP SCREENS


LTPHEMATOLOGY SYSTEM SETUP REVIEW CRITERIA REPORT


LTPHEMATOLOGY REVIEW CRITERION SETUP SCREEN


LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

  • Review criteria are grouped. A set (“batch”) of criteria is entered for each combination of instrument type/body fluid type/species (see slide 12)

  • Multiple sets can be active simultaneously, but only one set at a time can be active for each combination of instrument type/body fluid type/species

  • Sets and individual criteria can be de-activated

  • Specimens not matching any set are flagged

  • Sets can be printed

30


LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

Review criteria include

  • Limits

    • Parameter values

    • Products of 2 parameter values

    • Ratios of 2 parameter values

    • Sums of 2 parameter values

    • Differences of 2 parameter values

    • % differences of 2 parameter values

  • Morphology Flags

    • Presence

    • Severity

  • System Operational Alerts

    • Presence

    • Severity

      (CONTINUED ON NEXT SLIDE)

31


LTPHEMATOLOGY™

ENTER/EDIT REVIEW CRITERIA

Review criteria include:

  • Demographics

    • Age

    • Gender

  • Blanked results

  • Delta Checks(Apply to any combination of parameters listed above under limits)

    • Difference

    • Absolute difference

    • % difference

    • Absolute % difference

    • Rate of delta for any of the above, by:

      • Day, Week or Month

32


LTPHEMATOLOGY REVIEW CRITERIA BATCH SCREEN

INSTRUMENT TYPE

SPECIES

SPECIMEN TYPE

33


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

CRITERION

ACTION

PARAMETER THAT IS RE-ANALYZED

AFFECTED PARAMETER(S)

FORMULAS

34


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

PARAMETER LIST

35


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

MORPHOLOGY FLAG LIST

36


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

  • SYSTEM OPERATIONAL ALERTS

37


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

OPERATORS

38


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

RELATIONAL OPERATORS

39


LTPHEMATOLOGY REVIEW CRITERION EDITOR SCREEN

LIST OF ACTIONS

40


LTPHEMATOLOGY™

EVALUATOR MODULE

EVALUATOR Features

  • Follow-up procedure worklists are created based on your criteria

  • Special follow-up options include automatic replacement of instrument parameter values by values obtained on the instrument by other means; e.g. WIC/WOC

  • Audit trail maintenance:

    • Database archival of up to 500,000 specimen records

    • Every state of every record is stored in a database

    • All changes made to results are recorded/audit trailed

      • WHO, WHEN and WHY any change was made

      • WHAT Method used to make the change

  • Final disposition state for each specimen record is recorded

41


LTPHEMATOLOGY EVALUATOR MODULE SCREEN


LTPHEMATOLOGY™

PROCESSOR MODULE

Functions

  • Provides for all operations: label printing, data entry/modification, Supervisory review/approval, tracks current status and audit trail of results, and provides for archive and retrieval

    Features

  • Auto-verifies analyzer results

  • Issues follow-up worklists along with procedures

  • Provides data entry screens for necessary results changes

    • On-screen diffpad or microscopic observation entry

  • Determines final disposition

  • Stores every state of every specimen record in a database

43


LTPHEMATOLOGY™

PROCESSOR MODULE

PROCESSOR Features

  • Open architecture supports any combination of:

    • Analyzer manufacturers/models

    • Body fluid types

    • Species

  • Analyzes specimen results on-line in real-time, using your verification criteria.

    • Special verification options include:

      • Activation/de-activation of individual rules within a set

      • Advanced delta-check techniques

      • Color coding for: Rerun, Diff needed, Spun Hct

      • Tech ID, data entry, results and workstation tracked

44


LTPHEMATOLOGY PROCESSOR SCREEN


LTPHEMATOLOGY PROCESSOR SCREEN


LTPHEMATOLOGY REVIEW SPECIMEN RECORD DATA SCREEN

MORE SPECIMEN

INFORMATION

47


LTPHEMATOLOGY REVIEW SPECIMEN RECORD DATA SCREEN

REVIEW RATE BY ACTION

48


LTPHEMATOLOGY PROCESSOR SCREEN


LTPHEMATOLOGY™

ENDSHIFT MODULE

  • Functions

    • Closes Instrument Manager and Evaluator at predetermined times during the day

    • Creates shift reports that include

      • Overall workshift output

      • Technologist productivity

      • Analyzer outputs by table and graphical display

      • Review rules analysis

    • Saves reports on system server and emails reports to designated addresses

50


LTPHEMATOLOGY™

ENDSHIFT MODULE

  • Features

    • Endshift times can vary by day and shift

    • Multiple Endshifts per day can be programmed

    • Report contents and recipients are user definable

    • The Endshift process is entirely automatic

      • Stops Instrument Manager and Evaluator automatically

      • Restarts Instrument Manager and Evaluator automatically when Endshift process is completed

    • Endshift will not occur if LTPdetects that specimens are still being processed

    • Number of Endshift retries and retry intervals are user definable

51


LTPENDSHIFT REPORTED RESULTS

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT PENDING RESULTS

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT CUMULATIVE INSTRUMENT REPORT

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT INSTRUMENT MANAGER REPORT

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT INSTRUMENT MANAGER REPORT

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT INSTRUMENT MANAGER REPORT

YOUR LAB

ADDRESS, ETC


LTPENDSHIFT INSTRUMENT MANAGER REPORT

YOUR LAB

ADDRESS, ETC


LTPOPTIMIZER/HEMATOLOGY™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/HEMATOLOGYTM is software that helps you optimize specimen results throughput in the laboratory

    • It uses your results-verification criteria to measure the overall specimen-result review rate in the laboratory

    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or manual differentials

    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

59


LTPOPTIMIZER/HEMATOLOGY™

WHAT LTPOPTIMIZER DOES

Features

  • LTPOPTIMIZER/HEMATOLOGYTM provides review rates:

    • For all specimens combined

    • Based on individual review criterion

    • Based on instrument, for multiple-instrument systems

    • Based on instrument model, for labs using more than one analyzer model (open architecture)

    • Based on body fluid type, for labs running whole blood samples and other body fluids

    • Based on species, for veterinary labs

60


LTPOPTIMIZER/HEMATOLOGY™

LTPOPTIMIZER QUERY MODULE

Functions

  • Queries either the live or archival database for performance parameters

    • Productivity summary by analyzer or by operator

    • # of specimens analyzed over time interval per species, analyzer, tech, body fluid type, etc.

    • # of specimens work-listed per rule, per species, per analyzer, per body fluid type

    • # of follow-up actions per rule, per species, per analyzer, per body fluid type

      Features

  • Analysis of archived results based on rules applied live

  • Analysis of archived results using modified review rules

61


LTPOPTIMIZER QUERY CATEGORIES SCREEN


LTPOPTIMIZER QUERY RESULTS SCREEN


LTPHEMATOLOGY™

HOW LTPREDUCES OPERATING COSTS

  • Redeployment of skilled results-review staff

  • Eliminates erroneous specimen record handling decisions

  • Optimizes review criteria/follow-up processes

  • Provides audit trail

64


LTPHEMATOLOGY™

Hematology Products

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

LTPRAT BAL™

LTPGUINEA PIG BAL™

LTPMONKEY BAL™

LTPQCSENTINEL/HEMATOLOGY™

65


LTPBAL/HEMATOLOGY™

WHAT LTP BAL/HEMATOLOGY DOES

  • LTPBAL/HEMATOLOGY is software that automates BAL fluid specimen analyses on ADVIA 120/2120

    • No sample preparation

    • Reduces sample analysis time to approximately 1 minute/sample

    • Reports results in XL spreadsheet format

      • WBC

      • #,%Neuts

      • #,%Eos

      • #,% Mononuclear cells

    • Does NOT affect or alter ADVIA 120/2120 software

66


LTPBAL/HEMATOLOGY™

WHAT LTP BAL/HEMATOLOGY DOES

  • Product Features

    • WBC count @20 cells/µL

    • Differential @50 cells/µL

    • No RBC interference in WBC analysis

    • Species supported

      • Mouse allergic model and smoke inhalation model

      • Rat allergic model and smoke inhalation model

      • Cynomolgus monkey allergic model

      • Guinea pig allergic model

    • Does NOT affect or alter ADVIA 120/2120 software

67


Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Whole Blood

Comparative Results

Mouse BAL

Eos Model

Whole Blood Archetype

MNC

Lipid

Mouse BAL

Eos Model

BAL Archetype

PMN

MN

Eos

Lymphs

68


Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

EOS + Neuts Model

Whole Blood Archetype

Comparative Results

Mouse BAL

Eos + Neuts Model

BAL Archetype

69


Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Negative Control

Whole Blood Archetype

Comparative Results

Mouse BAL

Smoke Inhalation

Negative Control

BAL Archetype

70


Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Positive CTRL

Whole Blood Archetype

Comparative Results

Debris

Mouse BAL

Smoke Inhalation

Positive CTRL

BAL Archetype

71


Mouse

LTPBAL/HEMATOLOGY™

LTPMOUSE BAL™

Mouse BAL

Smoke Inhalation

Drug-Treated

Whole Blood Archetype

Comparative Results

Mouse BAL

Smoke Inhalation

Drug-Treated

BAL Archetype

72


Rat

LTPBAL/HEMATOLOGY™

Whole Blood

LTPRAT BAL™

BAL

Allergic Model

Negative Control

Whole Blood Archetype

Comparative Results

MNC

BAL

Allergic Model

Negative Control

BAL Archetype

Debris

MN

Eos

PMN

Neuts

Lymphs

73


Rat

LTPBAL/HEMATOLOGY™

LTPRAT BAL™

Rat BAL

Allergic Model

Positive Control

Whole Blood Archetype

Comparative Results

Rat BAL

Allergic Model

Positive Control

BAL Archetype

74


Rat

LTPBAL/HEMATOLOGY™

LTPRAT BAL™

Rat BAL

Allergic Model

Drug-Treated

Whole Blood Archetype

Comparative Results

Rat BAL

Allergic Model

Drug-Treated

BAL Archetype

75


LTPBAL/HEMATOLOGY™

Cynomolgus

Monkey

Whole Blood

LTPMONKEY BAL™

Cyno Monkey BAL

Allergic Model

Negative Control

Whole Blood Archetype

Comparative Results

Cyno Monkey

Allergic Model

Negative Control

BAL Archetype

Debris

MNC

MN

PMN

Eos

Neuts

Lymphs

76


LTPBAL/HEMATOLOGY™

Cynomolgus

Monkey

LTPMONKEY BAL™

Cyno Monkey BAL

Allergic Model

Positive Control

Whole Blood Archetype

Comparative Results

Cyno Monkey BAL

Allergic Model

Positive Control

BAL Archetype

77


Guinea Pig

LTPBAL/HEMATOLOGY™

Whole Blood

LTPGUINEA PIG BAL™

Comparative Results

Guinea Pig BALAllergic Model

Positive Control

Whole Blood Archetype

Guinea Pig BALAllergic Model

Positive Control

BAL Archetype

NMC

Debris

Eos

Neuts

Debris

78


LTPBAL/HEMATOLOGY™

HOW LTPREDUCES OPERATING COSTS

  • Automate time intensive manual process

  • Provide standardized objective criteria

  • Reduces specimen analysis time

  • Allows redeployment of skilled staff

79


LTPCOAGULATION™

Coagulation Products

LTPACHIEVER/COAGULATION™

LTPOPTIMIZER/COAGULATION™

LTPQCSENTINEL/COAGULATION™

80


LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/COAGULATION is a complete results processing system.

    • Auto-verifies coagulation analyzer results

    • Issues follow-up worklists along with procedures

    • Provides data entry screens for necessary results changes

    • Determines final disposition

    • Transmits results to the host computer system for release

    • Stores every state of every specimen record in a database

81


LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

Features

  • Open architecture supports any combination of:

    • Analyzer manufacturers/models

    • Body fluid types

    • Species

  • Analyzes specimen results on-line in real-time, using your verification criteria.

    • Special verification options include:

      • Activation/de-activation of individual rules within a set

      • Advanced delta-check techniques

      • Rerun-only criteria

82


LTPACHIEVER/COAGULATION™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria

  • Audit trail maintenance:

    • Database archival of up to 500,000 specimen records

    • Every state of every record is stored in a database

    • All changes made to results are recorded/audit trailed

      • WHO, WHEN and WHY any change was made

      • WHAT Method used to make the change

  • Final disposition state for each specimen record is recorded

83


LTPOPTIMIZER/COAGULATION™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/COAGULATION ™ is software that helps you optimize specimen results throughput in the laboratory

    • It uses your coagulation results-verification criteria to measure the overall specimen-result review rate in the laboratory

    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or prolonged clotting times

    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

84


LTPOPTIMIZER/COAGULATION™

WHAT LTPOPTIMIZER DOES

Features

  • LTPOPTIMIZER/COAGULATION ™ provides review rates:

    • For all specimens combined

    • Based on individual review criterion

    • Based on instrument, for multiple-instrument systems

    • Based on instrument model, for labs using more than one analyzer model (open architecture)

    • Based on body fluid type, for labs running whole blood samples and other body fluids

    • Based on species, for veterinary labs

85


LTPCHEMISTRY™

Chemistry Products

LTPACHIEVER/CHEMISTRY™

LTPOPTIMIZER/CHEMISTRY™

LTPQCSENTINEL/CHEMISTRY™

86


LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/CHEMISTRY is a complete results processing system.

    • Auto-verifies chemistry analyzer results

    • Issues follow-up worklists along with procedures

    • Provides data entry screens for necessary results changes

    • Determines final disposition

    • Transmits results to the host computer system for release

    • Stores every state of every specimen record in a database

87


LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

Features

  • Open architecture supports any combination of:

    • Analyzer manufacturers/models

    • Body fluid types

    • Species

  • Analyzes specimen results on-line in real-time, using your verification criteria.

    • Special verification options include:

      • Activation/de-activation of individual rules within a set

      • Advanced delta-check techniques

      • Rerun-only criteria

88


LTPACHIEVER/CHEMISTRY™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria

  • Audit trail maintenance:

    • Database archival of up to 500,000 specimen records

    • Every state of every record is stored in a database

    • All changes made to results are recorded/audit trailed

      • WHO, WHEN and WHY any change was made

      • WHAT Method used to make the change

  • Final disposition state for each specimen record is recorded

89


LTPOPTIMIZER/CHEMISTRY™

WHAT LTPOPTIMIZER DOES

  • LTPOPTIMIZER/CHEMISTRY ™ is software that helps you optimize specimen results throughput in the laboratory

    • It uses your chemistry results-verification criteria to measure the overall specimen-result review rate in the laboratory

    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns, below detection limit or dilutions needed.

    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

90


LTPOPTIMIZER/CHEMISTRY™

WHAT LTP OPTIMIZER DOES

Features

  • LTP OPTIMIZER /CHEMISTRY ™ provides review rates:

    • For all specimens and parameters combined

    • Based on your individual review criterion

    • Based on instrument, for multiple-instrument systems

    • Based on instrument model, for labs using more than one analyzer model (open architecture)

    • Based on body fluid type, for labs running whole blood samples and other body fluids

    • Based on species, for veterinary labs

91


LTPURINALYSIS™

Urinalysis Products

LTPACHIEVER/URINALYSIS™

LTPOPTIMIZER/URINALYSIS™

LTPQCSENTINEL/URINALYSIS™

92


LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

  • LTPACHIEVER/URINALYSIS is a complete results processing system.

    • Auto-verifies urinalysis analyzer results

    • Issues follow-up worklists along with procedures

    • Provides data entry screens for necessary results changes

      • On-screen microscopic observation data entry pad

    • Determines final disposition

    • Transmits results to the host computer system for release

    • Stores every state of every specimen record in a database

93


LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

Features:

  • Open architecture supports any combination of:

    • Analyzer manufacturers/models

    • Body fluid types

    • Species

  • Analyzes specimen results on-line in real-time, using your verification criteria.

    • Special verification options include:

      • Activation/de-activation of individual rules within a set

      • Advanced delta-check techniques

      • Rerun-only criteria

94


LTPACHIEVER/URINALYSIS™

WHAT LTPACHIEVER DOES

Features

  • Follow-up procedure worklists are created based on your criteria

  • Audit trail maintenance:

    • Database archival of up to 500,000 specimen records

    • Every state of every record is stored in a database

    • All changes made to results are recorded/audit trailed

      • WHO, WHEN and WHY any change was made

      • WHAT Method used to make the change

  • Final disposition state for each specimen record is recorded

95


LTPOPTIMIZER/URINALYSIS™

WHAT LTPOPTIMIZER DOES

  • LTP OPTIMIZER/URINALYSIS™ is software that helps you optimize specimen results throughput in the laboratory

    • It uses your urinalysis results-verification criteria to measure the overall specimen-result review rate in the laboratory

    • It determines the frequency of follow-ups based on each criterion, and the frequency of each follow-up procedure such as analyzer reruns or microscopic element types (eg. crystals)

    • It allows you to adjust the criteria and re-analyze the results so that you can optimize your criteria and improve throughput

96


LTPOPTIMIZER/URINALYSIS™

WHAT LTP OPTIMIZERDOES

  • Features

    • provides review rates:

      • For all specimens combined

      • Based on your individual review criterion

      • Based on instrument, for multiple-instrument systems

      • Based on instrument model, for labs using more than one analyzer model (open architecture)

      • Based on body fluid type, for labs running whole blood samples and other body fluids

      • Based on species, for veterinary labs

97


LabThroughPut™ Products

Quality Control Module

LTPQCSENTINEL™

LTPHEMATOLOGY™

LTPCOAGULATION™

LTPCHEMISTRY™

LTPURINALYSIS™

QC SENTINELMODULE

IS PRESENTLY UNDER DEVELOPMENT

98


General LIS Configuration

WITHOUTLTPMIDDLEWARE

  • An LIS has multiple connections and interfaces, in multiple categories

    • Analyzer – LIS

      • A different interface for each analyzer brand

    • Numerous Data Entry Workstations

    • Printers

99


General LIS Configuration

SLIDES

SLIDES

SLIDES

SLIDES

SLIDES

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

BC PRT

A1

A2

A3

SLIDES = slide-making workstations

DIFFS = Diff-reader workstations

PRT = Printer

BC PRT = Barcode printer

SUP WS1-3 = Supervisor workstations

InstMgr12 = Instrument Manager workstation

External Storage = Terabyte drive

A1-A14 = ADVIA 120 Analyzers

CD1-CD4 = CellDyn 3500 Analyzers

Notes:

1. Server-to-Server connection by dedicated NICs.

2. InstMgr-to-Analyzer and InstMgr-to-ANTRIM connections via serial ports.

3. Analyzer-to-ANTRIM failsafe direct serial port connections not shown.

4. Circled numbers are hub connection #s

PRT

A4

1-6

Sup

WS1

8-15

A5

A6

ANTRIM

A7

Sup

WS2

A8

A9

Sup

WS3

A10

A11

A12

A13

A14

Main

Server

Backup

Server

CD1

CD2

CD3

External

Storage

CD4


LTPMIDDLEWARE™ SYSTEM Configuration

WITH LTPMIDDLEWARE

  • The LIS has only a single connection to LTPMiddleware

  • LTPMiddleware is responsible for interfacing to the various categories of devices

  • LTPMiddleware unburdens the LIS of interfacing with multiple laboratory devices, each with its own interface specification

  • Bidirectional LTPMiddleware – LIS interfaces follow standards such as ASTM1381/1395 or HL7

101


LTPMiddleware System Configuration

SLIDES

SLIDES

SLIDES

SLIDES

SLIDES

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

DIFFS

BC PRT

A1

1-6

DSL

A2

8-15

7

A3

SLIDES = slide-making workstations

DIFFS = Diff-reader workstations

PRT = Printer

BC PRT = Barcode printer

SUP WS1-3 = Supervisor workstations

InstMgr12 = Instrument Manager workstation

External Storage = Terabyte drive

A1-A14 = ADVIA 120 Analyzers

CD1-CD4 = CellDyn 3500 Analyzers

Notes:

1. Server-to-Server connection by dedicated NICs.

2. InstMgr-to-Analyzer and InstMgr-to-ANTRIM connections via serial ports.

3. Analyzer-to-ANTRIM failsafe direct serial port connections not shown.

4. Circled numbers are hub connection #s

PRT

Hub

A4

Sup

WS1

A5

16-19

20

A6

21

22

LTP

Inst

Mgr

A7

Sup

WS2

A8

Main

Server

Backup

Server

A9

Sup

WS3

A10

A11

External

Storage

A12

A13

ANTRIM

A14

CD1

CD2

CD3

CD4


LTPMIDDLEWARE™ SYSTEM

LTPSystem Backup

  • LTPMIDDLEWAREautomatically copies the system environment, including applications and DB, to External Media daily

  • LTPMIDDLEWARE also continually replicates the environment to a Backup Server

  • The LTPBackup Server automatically takes over if the Main Server fails

103


LTPMIDDLEWARE™ SYSTEM

LTPSystem Technical Support

  • LTPTECHNICAL SUPPORT

  • Available whenever the laboratory is in operation

  • Lab personnel can call a telephone number and speak directly with support staff

  • Support staff have remote access to the middleware system which enables them to quickly diagnose a problem and to make any necessary changes

104


Thank You

for your attention.

www.labthroughput.com

845-425-9711

845-270-8449

105


ad