Professor stuart bunt 217
This presentation is the property of its rightful owner.
Sponsored Links
1 / 24

Professor Stuart Bunt 217 PowerPoint PPT Presentation


  • 78 Views
  • Uploaded on
  • Presentation posted in: General

New Methods of Imaging Brain Function. Professor Stuart Bunt 217. Traditional Anatomy. Phrenology, the study of bumps on the skull. Measuring brain weights and size (still being done..see the fuss about Einstein’s brain). Little link between morphology and performance

Download Presentation

Professor Stuart Bunt 217

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Professor stuart bunt 217

New Methods of Imaging Brain Function

Professor Stuart Bunt

217


Traditional anatomy

Traditional Anatomy

  • Phrenology, the study of bumps on the skull.

  • Measuring brain weights and size (still being done..see the fuss about Einstein’s brain).

  • Little link between morphology and performance

  • Neanderthal > Homo sapiens

  • Hydrocephalic genius


Plane film x rays

Plane Film X-rays

  • Not very good for showing soft tissues

  • Can show bone erosion

  • Large space filling masses may be picked up if they have largely differing X-ray absorption

  • Bone of skull requires high energy for penetration


Contrast media

Contrast Media

CAT with media around cord

Myelogram


Ventriculogram

Ventriculogram

  • Air is introduced into the ventricles via the lumbar cistern (in adults)

  • Via the fontanelles in infants

  • Patient placed on a tilting table, air fills ventricles

  • Can detect “space filling” lesions.

  • Causes severe headaches, same dangers as lumbar puncture.


Subtraction angiography

Subtraction Angiography

  • Radio opaque medium is introduced into the internal carotid artery or systemically.

  • Iodine compounds can promote allergic reactions, any arterial invasion dangerous.

  • Subtract X-ray before contrast medium from X-ray with contrast medium.

  • Can pick up any abnormality of the blood vessels.


Direct stimulation

Direct Stimulation

  • During operations surgeons may have to delimit crucial areas.

  • Epilepsy often spreads from a temporal lobe focus

  • The speech area on the planum temporale must be identified.

  • Cortex stimulated in conscious patient


Direct stimulation1

Direct Stimulation


Computerised axial tomography

Computerised Axial Tomography

  • Many X-rays are taken around the head (or body)

  • Matching detectors pick up absorbed signal

  • Computer reconstructs a “slice”

  • Axial slices can be reconstructed in to a 3D pictures


Cat method

CAT method


Professor stuart bunt 217

CAT


Magnetic resonance imaging 1

Magnetic Resonance Imaging 1

  • An extremely powerful magnetic field is used to orientate the spin of atoms.

  • A radio frequency pulse is used to cause some atoms to flip

  • Energy given off tells a lot about the molecule the atom is in

  • Can also be used to form images.


Cat vs mri

CAT vs MRI

  • MRI (previously known as nuclear magnetic resonance or NMR) is expensive.

  • The magnet is supercooled with liquid helium in a liquid nitrogen blanket.

  • Exposures are slow

  • No metal may enter the field (no pacemakers etc.)


Ultrasound

Ultrasound

  • Ultrasound produced by a piezoelectric crystal or array

  • No harm? Local heating and cavitation?

  • Doppler effect raises frequency as blood flows towards detector, lowers frequency in the opposite direction

  • Can map blood flow speed

  • Can detect vasospasm (a potentially lethal sequalae to a stroke)


Positron emission tomography

Positron Emission Tomography

  • Inject a very short lived (radioactive) isotope with extra proton into the internal carotid.

  • Produced in an (adjacent) cyclotron

  • Gives out a positron, leaving a neutron.

  • Positron anhilated when it hits and electron.

  • Produces two photons in opposite directions

  • Simultaneity detectors record the event.

Choice of labelled compound determines the result (transmitter etc.)


Professor stuart bunt 217

PET

Scanner

Cyclotron

Detector


Professor stuart bunt 217

PET


Professor stuart bunt 217

fMRI

  • By targeting protons in hydroxyl groups can measure blood flow

  • Areas of high flow = areas of high activity.

  • Usual advantages of MRI (see previous slide)

  • No radioactivity needed, replacing PET


Deep infrared

Deep Infrared

  • New technique

  • Involves use of far infrared to penetrate the skull

  • Reflected light picked up

  • Reflected better by areas of high blood flow

  • Experimental, low resolution as yet.


Squids

SQUIDS

  • Supercooled, quantum interference devices

  • Can pick up minute magnetic fields created by the activity of cells.

  • More localised than EEGs, not an “average”

  • Low resolution as the detectors are large


Professor stuart bunt 217

ERPS


Professor stuart bunt 217

EEGs

  • Extra cerebral recordings average all the electrical activity going on in the brain

  • Widespread changes can be picked up (epilepsy, coma, REM sleep etc.)


Labelling

Labelling


Professor stuart bunt 217

That's All Folks

See you in 325?

Advanced Neurocience


  • Login