An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Evaluation of Electronic Radiotherapy Data for Quality Checking Cancer Registry Data Colin Fox (NICR) Richard Middleton (NICR) Denise Lynd (BCH – COIS)

  2. Clinical Oncology Information System (COIS) • Radiotherapy Data – treatment intent, machine parameters, fractions, tumour site, dates. • Clinical Staging Data – from year 2000 all cancers exc. NM Skins (TNM, site-specific classifications, overall stage). • Chemotherapy Data – regimes, number of sessions, dates, drug details, dosages. • Detailed Patient Annotation Notes. • Approximately 4200 registrations annually of which around 2500 involve XRT.

  3. Methods • 1999-2002 COIS Radiotherapy data (13,730 XRT sessions relating to approx 9400 patients). • Patient and tumour data from COIS was matched to NICR Cancer Registration Database. • NICR tumour data relating to site, behaviour and diagnosis date were extracted for matched COIS registrations for which no tumour match was obtained. • COIS site and behaviour data as well as XRT start dates compared with corresponding NICR registration data using SPSS.

  4. Matching Results • Exact match at patient and tumour level. • 12,331 XRT sessions (89.8%) • 8348 registrations (89.0%) • Match at patient level but not tumour. • 1232 XRT sessions (9.0%) • 868 registrations (9.3%) • Not Matched to NICR • 167 XRT sessions (1.2%) • 167 registrations (1.8%)

  5. XRT Patients Not On NICR COIS registrations for selected sites that were missing from the NICR database: • Breast 37 (1% of annual incidence) • NM Skin 35 (0.4% of annual incidence) • Prostate 17 (0.8% of annual incidence) • Lung 16 (0.45% of annual incidence) • Other Sites 62 (0.35% of annual incidence) 167 cases <0.5% of annual incidence

  6. No Tumour Match: Site Different Malignant sites differed between NICR and COIS in 316 XRT sessions. Number of COIS cases differing on site for selected sites: • NM Skin 58 (0.42% of XRT cases) • Site Unspecified 43 (0.31% of XRT cases) • Lung 33 (0.24% of XRT cases) • Breast 24 (0.17% of XRT cases) • Other Sites 158 (1.15% of XRT cases) 316 (2.3% of XRT cases)

  7. No Tumour Match:Near Site • Lung & Mesothelioma 85 (0.62% of XRT cases) • Head & Neck 67 (0.49% of XRT cases) • Colon & Rectum 38 (0.28% of XRT cases) • Stomach & Oesophagus 34 (0.25% of XRT cases) • Lymphomas 27 (0.2% of XRT cases) • Cervix & Uterus 25 (0.18% of XRT cases) • Other Sites 63 (0.46% of XRT cases) “Near” meaning the malignant site is similar between both NICR and COIS (339 XRT sessions). Number of COIS cases differing for selected sites: 339 (2.47% of XRT cases)

  8. No Tumour Match:Behaviour Differences Both NICR and COIS agree on the site but one of the sources has it as non-malignant or metastatic (589 XRT sessions). Numbers of COIS cases differing on behaviour for selected sites: • Site Unspecified 138 (1% of XRT cases) • Breast 133 (0.97% of XRT cases) • Head & Neck 82 (0.6% of XRT cases) • Lung 68 (0.5% of XRT cases) • NM Skin 60 (0.44% of XRT cases) • Brain 53 (0.39% of XRT cases) • Other Sites 55 (0.4% of XRT cases) 589 (4.3% of XRT cases)

  9. Comparison of Diagnosis and XRT Start Dates • XRT began after diagnosis in majority of cases. • XRT administered just before diagnosis in around 4.5% of cases, with 3% getting XRT well before NICR diagnosis date. • Main sites – lung, breast, NM skin, head/neck and prostate. • Reasons? • Recurrent cases may account for some • Metastases requiring early XRT before diagnosis of the primary tumour • Possible missed pathology • Requires further investigation.

  10. PAS Pathology 39.1% 10.8% 23.6% (14.9%) (8.7% dths) (4.2% dths) 18.4% (7.6%) 2.2% 2.7% (1.8%) (0.8%) Deaths 0.6% (<0.1% dths) COIS Composition of NICR Tumour Registrations 1999-2002 (83.8%) 2.5% (23.9%)

  11. Summary and Conclusions • Over 90% of COIS data matches exactly • Of the 8% where tumour site differed, only 2% was significant (completely different tumour site to what was registered) • Highlighted missing registrations – approx 2% over the 4 years of COIS data (0.5% per year) • Helped reduce further an already low DCO rate • Just over 3% of cases where radiotherapy started significantly earlier than NICR diagnosis date.

  12. Recommendations • COIS represents a clinically rich new source of electronic data for NICR and will provide for: • Verification of NICR tumour registrations • Enhancement of treatment data on NICR • Electronic clinical staging data • Follow-up on cases where: • COIS tumour site differed completely to NICR and • XRT start dates occurred significantly earlier than the diagnosis date on NICR • Revision of system update rule for diagnosis date. • Carry out a similar investigation with chemotherapy data when available.