Honeywell – UDC2300  UDC2500 Conversion. [C]. UDC 2500. UDC 2300. More terminals, More features: UDC2300 : 16 terminals. UDC2500 : 27 terminals. New Case design NEMA 4X Standard The 2 instruments are not case compatible. Wiring is not identical. Digital Input. Gnd. 10. 19. 9. 8.

Download Presentation

UDC 2300

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Udc 2300

Honeywell – UDC2300  UDC2500 Conversion

[C]

UDC 2500

UDC 2300

  • More terminals, More features:

    • UDC2300 : 16 terminals.

    • UDC2500 : 27 terminals.

  • New Case design

    • NEMA 4X Standard

  • The 2 instruments are not case compatible.

  • Wiring is not identical

Digital Input

Gnd.

10

19

9

8

Output 2

or Alarm 2

L1

11

Power

Output 1

20

10

7

Input #1

L2/N

12

21

Auxiliary Output

11

6

Alarm 1

4

13

22

12

5

Output 2

or Alarm 2

Input #2

5

14

23

Output 1

Communication,

Auxiliary Output,

Digital Input

13

4

6

15

24

14

L2/N

7

16

25

Communication

Power

15

8

17

Input #1

L1

26

Alarm 1

Input #2

9

18

27

16

Gnd


Udc 2300

19

Honeywell – UDC2300  UDC2500 Conversion

Gnd.

20

L1

[C]

8

9

10

L2/N

21

Ground

Ground

7

11

22

10

L1

L1

4

23

L2/N

L2/N

5

12

6

11

24

4

20

21 if Current Output

6

5

12

13

UDC 2300

25

7

UDC 2500

5

19 if jumper is set for N.C.

21 if jumper is set for N.O.

19 if Current Output

26

8

14

13

4

27

9

L2/N

14

15

6

25

7

27

L1

15

16

8

26

17

Gnd

16

9

6 if jumper is set for N.O.

4 if jumper is set for N.C.

18

10

5

Out 2 or

Alarm 2

11

9 if jumper is set for N.O.

7 if jumper is set for N.C.

Input 1

DI

Output 1

Power

12

8

Aux. Out

Alarm 1

13

12 if Aux. Output

10 if Digital Input

17 if Communication

Output 1

Out 2 or

Alarm 2

Input 2

EXT. Option

14

13 if Aux. Output

11 if Digital Input

18 if Communication

Comm

Power

Alarm 1

Input 1

Input 2

15

23 for Volts

22 for ma

16

24