1 / 4

XDXL- Continuazione (IV anno) X-ray DRIFT E X TRA L ARGE Ts (c.n. A .Vacchi), Bo, Pd, Roma

XDXL- Continuazione (IV anno) X-ray DRIFT E X TRA L ARGE Ts (c.n. A .Vacchi), Bo, Pd, Roma.

shel
Download Presentation

XDXL- Continuazione (IV anno) X-ray DRIFT E X TRA L ARGE Ts (c.n. A .Vacchi), Bo, Pd, Roma

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. XDXL- Continuazione (IV anno) X-ray DRIFT EXTRA LARGETs (c.n. A .Vacchi), Bo, Pd, Roma (1)applicazioni all’astronomia X su satelliti (in collab con l’INAF ). LOFT (Large Observatory for x-ray timing), ESA M3 mission.(2)e alla bio-medicina (Bo, Pd-LNL). Compton camera per SPET animale e test su topi al “laboratorio di Radiofarmaci e Imaging Molecolare” (LRIM-LNL) (III anno)XDXL-PDP. Rossi(r.l), A. Battistella (LNL), M. Bello (LNL), C. Fontana, N. Liguori, G. Gennaro, G. Moschini (LNL), N.Uzunov(LNL), G. Zanella

  2. Attivita’ svolta nel 2011 1)Sviluppo di un “Dimostratore” di Compton Camera (CC) bio-medica per SPET animale, in collaborazione con la sezione di Bo. Il dimostratore ha caratteristiche suggerite dai test e dalle simulazioni realizzate nel 2010. Esso permettera’ di definire le caratteristiche di un futuro apparato operativo per misure di routine (richiesta 2012) e di studiare la ricostruzione tomografica . Questo dimostratore, in via di completamento, e’ costituito da: 4 moduli calorimetrici parzialmente dissimili con materiale in parte acquistato ex novo e in parte ottenuto da precedenti esperimenti. Vi e’ un modulo Tracker ‘provvisorio’ basato su uno dei rivelatori SDD a ‘piccola’ area prodotto dalla collaborazione per test. 2)Sviluppo degli algoritmi di ricostruzione tomografica di una CC per SPET animale (gia’ iniziato nel 2010 con test su eventi simulati da GEANT4) e verifica delle loro prestazioni a partire da distribuzioni reali di gamma provenienti da fantocci radioattivi e animali da test. ROSSI P., BALDAZZI G, BATTISTELLA A, BELLO M, BOLLINI D, BONVICINI V, FONTANA CL, GENNARO G, MOSCHINI G, NAVARRIA F, RASHEVSKY A, UZUNOV N, ZAMPA G, ZAMPA N, VACCHI A (2011). Design and performance tests of the calorimetric tract of a Compton Camera for small-animals imaging. NIMA, vol. 628; p. 430-433 FONTANA CL, BALDAZZI G, BATTISTELLA A, BELLO M, BOLLINI D, GALLI M, MOSCHINI G, NAVARRIA F, ZAMPA G, ZAMPA N, ROSSI P. (2010). Tomographic Back-Projection Algorithm for "Incomplete" Compton X-rays Detectors. In: Abstract Book, 21st International Conference on the Application of Accelerators in Research and Industry. Fort Worth (TX), August 8 – 13, 2010 (da essere pubblicato su AIP-CP 2011)

  3. Estensione 2012- Padova (B) STUDIO E SIMULAZIONE GEANT4 PER MISURE GAMMA SOPRA 1 MeV in BIO-MEDICINA -Monitor dosimetrico e funzionale in trattamenti adroterapici con imaging di gamma caratteristici fino a qualche MeV: O-16 (picchi a 6.13, 6.92 e 7.12 MeV) C-12 (picco a 4.44 MeV) -Imaging su animali con gamma emittenti sopra il MeV (Sc-44, Eg=1157 keV) • CAM. COMPTON (CC) OPERATIVA per IMAGING PICCOLI ANIMALI • (5 mod. Cal. + 3 Tracker) in coll. con Bo • >>angolo solido • >>efficienza tracker (3 + spessi) • > Risoluzione (H9500, 256 ch.) topo e trackers ingranditi mod. cal. 50 mm Cristallo pixellato (stride 1.5 mm) Multianode (256 channel) H9500 Acq basato su nuovo ASIC

  4. XDXL-Padova. Estensione 2012 FTE-TOT(2.5 PD, + 0.6 “in prestito” da LNL) P. Rossi (0.4, R.L.), G. Zanella (0.5), C.Fontana(0.4), N. Liguori(1.0), G.Gennaro (0.2), G.Moschini (LNL, 0.3), A. Battistella (LNL, 0.1), N.Uzunov(LNL,0.2), M. Bello(LNL) INTERNO (LNL -LRIM (0.5 fte per un anno) e riunione di collaborazione) 2 kE ESTERO (1 congresso) 3 kE CONSUMO -generatori nucleari” di radio-isotopi medici (Tc-99) per test su animali) 3 kE -Materiali meccanici ed elettrici per la costruzione CC 2 kE APPARATI (2/5 moduli calorimetri CC : two pmt H9500, 2 scint.) 22 kE TOTALE 32 kE Ufficio Tecnico, progetto meccanico supporto CC 1 m.u. Officina Meccanica , costruzione supporto CC 2 m.u. Officina elettronica, connessioni elettriche CC 1 m.u.

More Related