ICP. MAKING STANDARDS. NUMBER OF STANDARDS. Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc). BLANK. Blanks are prepared from reagent grade water with 3% trace metal grade nitric acid.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' ICP' - sereno


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1
ICP
  • MAKING STANDARDS
number of standards
NUMBER OF STANDARDS
  • Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc)
blank
BLANK
  • Blanks are prepared from reagent grade water with 3% trace metal grade nitric acid.
  • Blanks are typically prepared in 2L lots by adding 60 mL of concentrated HNO3 to 1940 mL of water (using a pre-marked bottle available in the PQ lab).
iv icpms 71a standard
IV-ICPMS-71A Standard
  • Typically, the ICP standard used IV-ICPMS-71A, which contains of 10 ppm Ag, Al, As, B, Ba, Be, Ca, Cd, Ce, Co, Cr3, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ho, K, La, Lu, Mg, Mn, Na, Nd, Ni, P, Pb, Pr, Rb, S, Se, Sm, Sr, Th, Tl, Tm, U, V, Yb, Zn.
  • This solution is diluted with the blank solution to prepare working ICP standards.
100 ppb
100 ppb
  • Dilute the stock 100 times.
  • For a 200 ml sample pipette 2 ml of the ICP Stock and dilute to 200 g with the blank solution.
500 ppb
500 ppb
  • Dilute the stock 500 times.
  • For a 200 ml sample pipette 10 ml of the ICP Stock and dilute to 200 g with the blank solution.
1000 ppb
1000 ppb
  • Dilute the stock 1000 times.
  • For a 200 ml sample pipette 20 ml of the ICP Stock and dilute to 200 g with the blank solution.
hints on preparing solutions
Hints on Preparing Solutions
  • All bottles must be very clean.
  • Use gravimetric measurements whenever possible.
    • Ie. Weigh solutions instead of pipetting.
  • Do not pipette directly out of ICP stock solutions; pour instead into a falcon tube. This avoids contamination.
  • Check the calibrates on pipettes when making up standards.