An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Programming Software and Setting

  2. SB-DN-1IP Programming Module Data interchange  for S-BUS and TCP/IP Reset without Power off Intelligent Data Transfer Remote programming Network capacity : 254 S-BUS devices Default IP Add:192.168.10.250, also can be changed via Programming Software , if forget IP address, Programmer can press the IP button and recover to Default one(IP LED light on and power off)

  3. Communication setting Ethernet Setting IPAdd:192.168.10.250 Router IP:192.168.10.001 ☺ Before Programming, Make sure that Programming module and PC are at the same IP range Cross-ruling IP setting PC IP Setting Make sure Make sure that Programming module and PC are at the same IP, Example: 192.168.10 Same and the last one not exceed 255

  4. Communication setting Picture 1 Picture 2 * Another way to test and double check IP setting, Programmer can do as following steps: “Star”“Run”,input “cmd”and confirm, then input “ping192.168.X.X ” (IP add of programming Module) , to see the communication is ok or not.

  5. 2.1 Software introduce Smart-bus Programming module is used to program all on-line devices

  6. Programming You can not find it in the device list, you can find by Step1: S-BUS software DevicesBus switchboard click to enter BUS switchboard

  7. Programming Step2: select a device to view status and edit We can see the switchboard’s version, and all devices which linked to current switch.

  8. Programming Step3: View/Edit network parameter The default port : 6000 Make sure the device’s IP and PC’s are in the same network segment

  9. Programming Step4: View/Edit configuration Switchboard ID(Device ID): separate different switchboard Subnet ID: set current S-BUS network ID. Switchboard ID( Device ID) is used for differentiate differ switches. 1port switch offers a subnet ID for all S-BUS devices which linked to its s-bus current port.

  10. Software Toolbar Menu Smart-bus Programming software main page

  11. Device search 1、Click this Button to search device

  12. Device search 1、Select 255 to search all on-line device 2、Click Search

  13. Device search 2、Add all searched product list 1、Device searched

  14. Device search 1、on-line device List 2、double click to enter setting page of that device

  15. Add Manage 2.2 Device IP manage Select Add manage Note: if the IP add of new added device or changed device can not meet the Project application , it maybe cause IP conflict or can not communication, so we must modify subnet ID and Device ID according the MAC address.

  16. 2、Right click or double click for modify device MAC address 3、 Set subnet ID and Device ID according the MAC address, then Save. Programmer can delete the former device in list. 2.2 Device IP manage

  17. Add Manage 2、Select ”Modify address ”to set IP address 1、press this button 3second to active the IP add modification function(LED on in red from twinkle)

  18. Add Manage 3、Click ”indicate initial address”, add of device that LED on in red will be read 4、input new add, then click “Modify initial address ”, it will be saved and the LED will be twinkled