Round Robin II Calibration/Test Results
This presentation is the property of its rightful owner.
Sponsored Links
1 / 47

Round Robin II Calibration/Test Results PowerPoint PPT Presentation


  • 56 Views
  • Uploaded on
  • Presentation posted in: General

Round Robin II Calibration/Test Results. Impact of Burner Tab and Intake Duct on Calibration/Test Results. Variations in Burner Air Turbulators Discovered. Round Robin II Calibration Requirements. Air Intake Velocity: 2150 +/- 50 ft/min. Thermocouple Rake Temperatures: 1850+/- 100 o F.

Download Presentation

Round Robin II Calibration/Test Results

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Round robin ii calibration test results

  • Round Robin II Calibration/Test Results

  • Impact of Burner Tab and Intake Duct on Calibration/Test Results

  • Variations in Burner Air Turbulators Discovered


Round robin ii calibration test results

Round Robin II Calibration Requirements

  • Air Intake Velocity: 2150 +/- 50 ft/min

  • Thermocouple Rake Temperatures: 1850+/- 100oF

  • Heat Flux: 16.0 +/- 0.8 Btu/ft2 sec


Round robin ii calibration test results

Round Robin II Recommended Burner Configuration

  • Igniters @ 10:00 Position

  • 1 Tab in Top Left Position

  • Static Disc In Draft Tube

  • 3.75-Inch Distance from Nozzle Tip to Turbulator


Round robin ii calibration test results

Round Robin II Material Combinations:

1) 2 Layer 0.60 lb/ft3 Fiberglass

2) 1 Layer Nextel Ceramic Paper/2 Layer 0.42 lb/ft3 Fiberglass

3) 2 Layer 0.60 lb/ft3 Curlon

4) 1 Layer TTI Felt/1 Layer 0.42 lb/ft3 Fiberglass


Round robin ii calibration test results

FAATC Round Robin II Tab/Igniter Arrangement


Round robin ii calibration test results

FAATC Round Robin II Tab/Igniter Arrangement


Round robin ii calibration test results

Various Burner Arrangements Used in Round Robin II


Round robin ii calibration test results

Influence of Tab and Intake Duct on Calibration and Test Results


Round robin ii calibration test results

Position of Flame Deflection Tab


Round robin ii calibration test results

4 Burner Configurations:

No Tab/With Duct (NTWD)

No Tab/No Duct (NTND)

With Tab/With Duct (WTWD)

With Tab/No Duct (WTND)


Round robin ii calibration test results

Tab/Intake Duct Test Conclusions

Burner Calibration Influenced More From Tab Than Duct

Test Results Influenced More From Burner Set-up Than Calibration

No Tab = Temp Calibration = Quicker Failure Time

/


Round robin ii calibration test results

Influence of Turbulator on Calibration and Test Results


Round robin ii calibration test results

Differences Between “Old” and “New” Park Burners

Old

New

2 3/4-Inch Turbulator

2 5/8-Inch Turbulator

Opposing Turbulator Flow

Identical Turbulator Flow

No Static Disc

Static Disc


Round robin ii calibration test results

Old and New Style Turbulators

Old

New

2 3/4” I.D.

2 5/8” I.D.

C.W.

C.W.

C.C.W.

C.W.

4” O.D.

3 7/8” O.D.

No Disc

Disc


Round robin ii calibration test results

Burner Equipment Assortment


Round robin ii calibration test results

Monarch H215 Turbulator with Static Disc