Round Robin II Calibration/Test Results
Download
1 / 47

Round Robin II Calibration/Test Results - PowerPoint PPT Presentation


  • 75 Views
  • Uploaded on

Round Robin II Calibration/Test Results. Impact of Burner Tab and Intake Duct on Calibration/Test Results. Variations in Burner Air Turbulators Discovered. Round Robin II Calibration Requirements. Air Intake Velocity: 2150 +/- 50 ft/min. Thermocouple Rake Temperatures: 1850+/- 100 o F.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Round Robin II Calibration/Test Results' - samson-conrad


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

  • Impact of Burner Tab and Intake Duct on Calibration/Test Results

  • Variations in Burner Air Turbulators Discovered


Round Robin II Calibration Requirements

  • Air Intake Velocity: 2150 +/- 50 ft/min

  • Thermocouple Rake Temperatures: 1850+/- 100oF

  • Heat Flux: 16.0 +/- 0.8 Btu/ft2 sec


Round Robin II Recommended Burner Configuration

  • Igniters @ 10:00 Position

  • 1 Tab in Top Left Position

  • Static Disc In Draft Tube

  • 3.75-Inch Distance from Nozzle Tip to Turbulator


Round Robin II Material Combinations:

1) 2 Layer 0.60 lb/ft3 Fiberglass

2) 1 Layer Nextel Ceramic Paper/2 Layer 0.42 lb/ft3 Fiberglass

3) 2 Layer 0.60 lb/ft3 Curlon

4) 1 Layer TTI Felt/1 Layer 0.42 lb/ft3 Fiberglass







4 Burner Configurations: Results

No Tab/With Duct (NTWD)

No Tab/No Duct (NTND)

With Tab/With Duct (WTWD)

With Tab/No Duct (WTND)


Tab/Intake Duct Test Conclusions Results

Burner Calibration Influenced More From Tab Than Duct

Test Results Influenced More From Burner Set-up Than Calibration

No Tab = Temp Calibration = Quicker Failure Time

/



Differences Between “Old” and “New” Park Burners Results

Old

New

2 3/4-Inch Turbulator

2 5/8-Inch Turbulator

Opposing Turbulator Flow

Identical Turbulator Flow

No Static Disc

Static Disc


Old and New Style Turbulators Results

Old

New

2 3/4” I.D.

2 5/8” I.D.

C.W.

C.W.

C.C.W.

C.W.

4” O.D.

3 7/8” O.D.

No Disc

Disc




ad