Barrel Pressure Drop Measurements. Purpose: Measure pressure in module due to purging gas flow Module could bulge if pressure too high Method: Module has 4 purging gas holes: Use 2 for gas flow, 2 for pressure sensors Measure pressure near input and output at 3 fixed flow rates of N 2

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Barrel Pressure Drop Measurements' - sadah


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Barrel pressure drop measurements
Barrel Pressure Drop Measurements

  • Purpose:

    • Measure pressure in module due to purging gas flow

    • Module could bulge if pressure too high

  • Method:

    • Module has 4 purging gas holes:

      • Use 2 for gas flow, 2 for pressure sensors

    • Measure pressure near input and output at 3 fixed flow rates of N2

      • ~0.9 l/min, 3.5 l/min, 6.6 l/min



Barrel pressure drop measurements2
Barrel Pressure Drop Measurements

  • Duke setup – detail of pressure sensor:



Barrel pressure drop measurements4
Barrel Pressure Drop Measurements

  • Interpolate to 1.5 liters/min N2:

    • (with CO2, pressures ~ 15% lower)

    • Type 3 module with nothing on output:

      • 0.54 mbar near input

      • 0.04 mbar near output

    • Effect of button attached to output:

      • +0.20 mbar near input

      • +0.22 mbar near output

    • Effect of gas fitting attached to output:

      • +0.24 mbar near input

      • +0.32 mbar near output