Operational conditions for current leads in the DFBs. Sandrine Le Naour. Commissionning tests.

Download Presentation

Operational conditions for current leads in the DFBs

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Operational conditions for current leads in the dfbs

Operational conditions for currentleads in the DFBs

Sandrine Le Naour


Commissionning tests

Commissionning tests

  • During the hardware commissionning period, for each circuit, a test is dedicated to the verification of the correct operation of the current leads. The test lasts at least 1 hour to the operationnal current

    • 600A correctors : PNO.a3

    • IPQ : PNO.c4

    • IPD : PNO.c2

    • RB, RQF/D : PLI3.a5

       AnalysiswithDFB application

S. Le Naour / MP3 meeting


Parameters

Parameters

  • TT893 : Temperatureat the top of currentleads (resistive part). Cartridge heaters are incorporated inside the top part of each current lead to avoid heavy condensation or ice formation when the current leads are operating at zero current or at a current lower than the nominal one. These heaters maintain a temperature of 40°C (313K).

    • Below 280K cryostartisremoved for the subsector. CV891 isclosed.

    • Above 320K cryooperatorreceives an alarm (no action on cryostart or cryomaintain)

    • Above 330K (~60°C) : The power permit isremoved on the power converter.

  • TT891A : Temperaturebetweensuperconductive and resistive parts of the currentlead. The optimal temperatureis 50K. The currentleadcoolingisobtainedwith a gaz flow of 20K whichiscontrolled by the CV891valve

    • Below 45K and above 55K, cryomaintainisremoved

  • CV891 : Opening in % of the valve.

S. Le Naour / MP3 meeting


Parameters1

Parameters

  • U_RES : Voltage over the resistive part of currentlead. Signal from QPS. QPS tripping if ¦U_RES¦ > 100mV (160mV on correctors in DFBX)

    • 600A correctors : ¦LDx.U_RES¦ < 20 mV @400A, ¦LDx.U_RES¦ < 30 mV @550A

    • IPD, IPQ ¦LDx.U_Res¦ < 35mV @4310A, ¦LDx.U_Res¦ < 45mV @5390A

    • RB, RQF, RQD, 12kA ¦LDx: U_RES¦ < 40mV @ 12kA

  • U_HTS : Voltage over the superconductivepart of currentlead. Signal from QPS.

    QPS tripping if ¦U_HTS¦ > 3mV

S. Le Naour / MP3 meeting


What do we observe

What do we observe ?

TT891A : Regulationat 50K

600A correctors : in general variation of +/-0.5K atzerocurrent or after a single ramp and +/-1K after the ramps (Ipno ->0 and 0 -> -Ipno).

IPD, IPQ : in general variation of +/- 1K (Ipno =2800A isstilltoolow)

variation +/- 2 K isstill all right if more sent a warning to cryo team ?

TT 893 : If > 315K sent a warning to Amalia and Sandrine.

A global compaignwillbedone to check the temperaturesensors (pt100) and the regulatorswhen TT893 > 315K.

S. Le Naour / MP3 meeting


What do we observe1

What do we observe ?

  • CV 891A ! (RD1.L2)