GSM FCT for Emergency Applications Matrix SIMADO GFX11E

GSM FCT for Emergency Applications Matrix SIMADO GFX11E. INTRODUCTION. Fixed cellular terminal for voice applications in emergency situations Built-in Battery back-up Send notification SMS during power failure and low battery detection Incoming calls on GSM are routed to the FXS port

rtamez
Download Presentation

GSM FCT for Emergency Applications Matrix SIMADO GFX11E

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GSM FCT for Emergency Applications Matrix SIMADO GFX11E

  2. INTRODUCTION • Fixed cellular terminal for voice applications in emergency situations • Built-in Battery back-up • Send notification SMS during power failure and low battery detection • Incoming calls on GSM are routed to the FXS port • Outgoing calls from FXS port are routed through GSM network

  3. System Interfaces FXS Port(RJ11) ON/OFF SWITCH DC Power Jack SIM ANTENNA SIMADO GFX11E

  4. LED Indications • FXS (Phone On/Off Hook) • NW (Network Availability) • SIM (SIM Card) • Power On (System ON/OFF) • Battery (Level Indication) SIMADO GFX11E

  5. Elevator Application

  6. GSM FCT for Emergency Applications Product Variants

  7. Application Areas

  8. System Features • International Mobile Equipment Identity (IMEI) • Location Information Indication • Network Selection • Service Provider Lock • Signal Strength Indication • SIM PIN • System Programming • System Security • Allowed and Denied List • Automatic Number Translation • Call Divert • Call Duration Display • Call Progress Tones • Emergency Number Dialing • Battery Level Notification • Hotline

  9. Network Support GSM Quad-band WCDMA Tri-band GSM850 EGSM900 DCS1800 PCS1900 850 1900 2100 SIMADO GFX11E

  10. 3G Network Support • Matrix SIMADO GFX11E 3G supports: • 2G Network: Quad-band support for GSM network • 3G Network: Penta-band support for UMTS network • Call established over 3G network offer: • Noise-free, stanch voice quality • Enhanced security • Fallback compatibility • Flexibility to switch to alternate network (2G) • Assures round-the-clock network connectivity • Users can traverse between regions uninterruptedly

  11. Network Selection • Once the Power is ON, system searches and registers itself with the available network • Network is selected as per network signal strength • Ensures round-the-clock connectivity by registering with an available network • System can be configured for manual network selection mode • Avoids unnecessary charges due to registration with unwanted networks • Network is selected as per assigned priority in a priority table • Single GSM port can be programmed for maximum of 4 networks • Multiple attempts are made to register with an available network

  12. Battery Level Notification • GFX11E sends battery level notification SMS to the Help Center to notify built-in battery level of FCT • Type: NI-MH AAA 7.2V/800mA • Talk Mode: 2 hours • Idle Mode: 4 hours • Notification SMS: • When power fails • When low battery detected

  13. Hotline (Fixed Dialing) • Just by lifting the handset, the frequently dialed number can be dialed-out • Configure the fixed number to be dialed after programmed time • Beneficial in point-to-point connectivity set-ups

  14. Emergency Number Dialing • Configure 4 emergency numbers (Ex. Ambulance, Police, Fire Brigade and Others) • Place call even if SIM is not present • Configured emergency numbers are excluded from such verification • In case, no emergency number is programmed • Emergency number stored in SIM will be dialed • Else default emergency number stored in the firmware will be dialed

  15. Signal Strength • Gauge available signal strength • 15 step signal strength indication on telephone instrument‘s LCD screen • Telephone instrument should be FSK compatible

  16. System Programming • Program the device with a phone • Two differentiated programming levels: • System Engineer (SE) Level: • Grants full system access • Password authentication is required to enter SE programming mode • System Administrator (SA) Level: • Authorized to program only administrative system features • Password authentication is required to enter SA programming mode

  17. Specifications