Goes 13 striping
Download
1 / 7

GOES-13 Striping - PowerPoint PPT Presentation


  • 101 Views
  • Uploaded on

GOES-13 Striping. The GOES-13 Sounder now shows much more striping than GOES-12 in some bands, for example band 7 (12 um). The striping is seen in both GVAR count and radiance space (and brightness temperature). This level of striping can affect products. Jim Nelson Don Hillger Tim Schmit.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' GOES-13 Striping' - ronda


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Goes 13 striping

GOES-13 Striping

The GOES-13 Sounder now shows much more striping than GOES-12 in some bands, for example band 7 (12 um).

The striping is seen in both GVAR count and radiance space (and brightness temperature). This level of striping can affect products.

Jim Nelson

Don Hillger

Tim Schmit



IMGLIST A.6313 6414 Image file directory listing for:A --- -------------  ------------  --------  ---- ---- ------------ 6313  G-12 SND       9 NOV 06313  17:46:00    35   87 1-19 6314  G-13 SND       9 NOV 06313  17:46:00    35   94 1-19 IMGLIST: done

LINESTAT 6313 6313 7 7 TYPE=RAD #           79     2006313      174600 (GOES-12) #DECT AVG     VAR         BAND  NLINES   MIN      MAX 1       103.12       19.84           7         49.         0.0       153.0 2       103.14       19.91           7         49.         0.0       150.8 3       103.48       19.91           7         49.         0.0       150.8 4       103.38       19.92           7         49.         0.0       150.0 LINESTAT 6314 6314 7 7 TYPE=RAD #          181     2006313      174600 (GOES-13)

#DECT AVG     VAR         BAND  NLINES   MIN      MAX 1       106.25       18.97           7         49.         0.0       151.8 2       106.25       18.94           7         49.         0.0       151.4 3       106.70       18.87           7         49.         0.0       171.8 4       107.20       19.44           7         49.         0.0       157.0

Radiance-space Note the larger spread of GOES-13 AVG (average) values


Sounder DPI of TPW

GOES-12 Native Projection


Sounder DPI of TPW

GOES-13 Native Projection