Database in analysis
This presentation is the property of its rightful owner.
Sponsored Links
1 / 21

Database in Analysis PowerPoint PPT Presentation


  • 98 Views
  • Uploaded on
  • Presentation posted in: General

Database in Analysis. Kanglin He 17 June, 2007. Outline. General run status database From DAQ, slow control and offline group Luminosity & beam parameters From tools group Data correction related coefficients From tools and Physics groups, rec V related

Download Presentation

Database in Analysis

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Database in analysis

Database in Analysis

Kanglin He

17 June, 2007


Outline

Outline

  • General run status database

    • From DAQ, slow control and offline group

  • Luminosity & beam parameters

    • From tools group

  • Data correction related coefficients

    • From tools and Physics groups, rec V related

  • Data Quality Assurance (DQA) database

    • From Validation group, rec V related

  • Physics Quality Assurance (PQA) database

    • From Physics groups, rec V related


General run status

Run type

Cosmic/collision

J/psi, Psi’, R, tau, etc

Detector status

Status: good/usable/bad

Reason: HV trap, gas unusual, noise, etc,…

Electronics status

Status: good/usable/bad

Reason: dead channel, noise, etc,

Calibration status

Status: good/usable/bad

Reason: T0 problem, resolution too bad, etc

Run status

Status: good/usable/bad

Reason: detector/ electronic/ calibration

General run status


Luminosity beam parameter

Offline luminosity

Bhabha

Dimu

Diphoton

Average luminosity

Errors

Statistic

Systematic ?

Beam energy

Beam energy

Beam energy spread

Beam position

X, Y, Z

Errors of X, Y, Z

Luminosity & beam parameter


Data correction coefficients

Data correction coefficients

  • Second calibration of each detector

    • MDC, dE/dx

    • TOF, offset correction, t0 correction

    • EMC, photon energy correction

    • MUC, noise and efficiency

  • More corrections from tools/physics groups


Dqa database

DQA database

  • General data qualities check

    • Status and related Histogram

  • Key distributions for each detector

  • Common systematic uncertainties table

    • Tracking:

      • Particle species

      • Dimensioned by momentum and polar angle

    • Neutrals

    • PID


Pqa distribution

PQA distribution

  • Key variables monitoring

    • Invariant mass, angular distribution, etc

    • Histogram

  • Special physics tags monitoring

    • Tag numbers, key variable histograms

  • Fine correction coefficients for data and beam energy

  • Systematic error tables for common analysis topic


Database in analysis

各系统数据字典汇总

  • 在线

  • 慢控制

  • 离线


Database in analysis

在线 RunInfo —— 运行各RUN的信息


Database in analysis

在线MDC机箱编号、机箱地址信息


Database in analysis

在线 EMC电子学配置信息


Database in analysis

慢控制


Database in analysis

慢控制

  • MDC探测器温湿度42路

  • 探测器外围环境温湿度

  • MDC探测器高压状态

  • MDC探测器高压值

  • MDC探测器高压值

  • MDC高压插件温度

  • EMC桶部温度

    • EMC桶部温度60槽×8=480路

  • EMC桶部温湿度

    • 桶部每槽东西两端各一个温湿度传感器,60槽*2(东西)*2(温湿)=240


Database in analysis

慢控制(Cont.)

  • EMC端盖温度120路(未安装)

  • EMC端盖温湿度40路(未安装)

  • TOF温度40路(测试中)

  • TOF高压452路,插件温度40路(未安装)

  • Muon桶部温度

    • Muon桶部共16条电缆,每条电缆8个传感器,16*8=128路

  • Muon桶部温湿度32路

  • Muon端盖温湿度128路


Database in analysis

慢控制(Cont.)

  • Muon高压144路,插件温度12路(未安装)

  • EMC NIM机箱温度600路(未安装)

  • EMC NIM机箱电压240路(未安装)

  • Muon低压电源电压电流88路(未安装)

  • Muon低压电源温度44路(未安装)

  • TOF低压电源电压电流24路(未安装)

  • TOF低压电源温度8路(未安装)

  • MDC VME机箱监控304路

  • EMC VME机箱监控304路(未安装)

  • TOF, Muon, Trigger VME机箱监控共9台(未安装)


Database in analysis

慢控制(Cont.)

  • Online PC farm温度70路

  • 探测器环境温度100路

  • 电缆槽温度100路

  • 电子学环境温湿度20路

  • BESIII房间温湿度32路

    • 16(BES大厅)、4(Online room),8(Control room)、4(Trigger room)

  • 气体系统(未安装)

  • 安全联锁系统(未安装)


Database in analysis

离线


Database in analysis

Run_Number

int(11)

Run号

Muon_Temp

decimal(6,2)

Muon探测器的温度

Tof_Temp

decimal(6,2)

Tof探测器的温度

Emc_Temp

decimal(6,2)

Emc探测器的温度

Mdc_Temp

decimal(6,2)

Mdc探测器的温度

表名:SC-Offline

表名:OnLine-OffLine


  • Login