Residential air handlers
This presentation is the property of its rightful owner.
Sponsored Links
1 / 25

RESIDENTIAL AIR HANDLERS PowerPoint PPT Presentation


  • 39 Views
  • Uploaded on
  • Presentation posted in: General

RESIDENTIAL AIR HANDLERS. AR SERIES. AR. Nomenclature. AR RESIDENTIAL. AR Multi-position electric air handler. Versatile up flow, right or left horizontal, and counter flow multi-position May be located in closet, utility room, attic, or basement

Download Presentation

RESIDENTIAL AIR HANDLERS

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Residential air handlers

RESIDENTIALAIR HANDLERS

AR SERIES


Residential air handlers

AR


Nomenclature

Nomenclature


Ar residential

AR RESIDENTIAL


Ar multi position electric air handler

AR Multi-positionelectric air handler

  • Versatile up flow, right or left horizontal, and counter flow multi-position

  • May be located in closet, utility room, attic, or basement

  • Equipped with a check flow rater for Heat pump and Cooling Unit Operation

  • Power supply entry at top


Airflow orientation

Airflow Orientation

Important:

Remove the horizontal pan when unit is installed in unconditioned i.e. (Garage, Attic) application, or downflow applications, and install insulation kit on vertical (donut shape) drain pan. Insulation kits should be ordered as follows:

DPI 18-30/20 (AR18-32)

DPI 36-42/20 (AR36-42)

DPI 48-61/20 (AR48-61)

*Horizontal Right Discharge

Tube and Drain conn. front

Downflow discharge

(with plastic vertical pan only)

*Upflow

Discharge

Horizontal Left Discharge

Tube and Drain conn. front


Ar air handlers

AR Air Handlers

  • All air handlers use direct drive motors. Power supply is 208/230 Volts, 60 HZ, 1 Phase

  • AR is designed for zero (0”) inch clearance, however, adequate access for service or replacement must be considered


Refrigerant tubing

Refrigerant tubing

  • Refrigerant tubing should be installed as to avoid undue stress.

  • Suction tube should be insulated with a closed cell insulation and the seams sealed


Condensate removal

Condensate Removal

  • AR air handlers employ a draw-through coil, therefore a trap must be installed in the drain lines.

  • A “P” trap is required.

  • Precautions must be used not to over tighten the adapter at the drain pan connection.

  • A joint compound should be used to prevent leakage and act as a lubricant.

  • All condensate drain lines and drain traps should be adequately insulated.

  • The unit and the auxiliary drain pan must be adequately elevated to insure proper drainage.


Condensate removal1

Condensate Removal


Electrical connections

Electrical connections

  • Copper wire is recommended for all electrical connections.

  • 24 Volt thermostat connections

  • Goodman Cooling and Heating thermostat part number is CHT18-60.

  • Goodman Heat Pump thermostat part number is HPT18-60.


Electronic controls blower fan controls

Electronic Controls Blower Fan Controls


Goodman part b1370735

Goodman Part #: B1370735


Operating tolerances ranges

Operating Tolerances & Ranges

  • +80 to -40 Degrees Celsius (+176 to -40 F)

  • 5% to 95% R.H. Non-Condensing

  • 18 to 30VAC Control Voltage

  • Frequency - 60Hz/50Hz

  • Approved to UL353


Normal operation

Normal Operation

  • Blower On Delay

    • “G” Input Energizes

    • Blower Motor energized after a 7 second delay

  • Blower Off Delay

    • “G” Input De-energizes

    • 65 Second Delay before Blower Motor turns off.

  • Field And Factory Speedup Test Mode

    • If “R” applied to “SPEEDUP” Terminal

      • Both “G” Delay Timings On & Off are Immediate

    • If “C” applied to SPEEDUP Terminal

      • Delay On Timing is 3 Seconds

      • Delay Off Timing is 5 Seconds


Field returns

Field Returns

  • Handling Boards by Edges or Use ESD Ground Strap

  • Boxes or Bags for Field Returns

  • No Repeated Control Change-out

  • Moisture Control in Board Area

  • Return Tag Information


Ground check

Ground Check

  • Meter set to Ohms or Resistance Setting

  • Place Meter from GROUND quick connect to chassis ground

  • Reading should be near Zero ohms

  • Issue: GROUND Quick Connect Loose ; causes board resetting when blower starts

  • Issue: Flame Sensing problems if improper grounding in system


Residential air handlers

Low Voltage Wiring 10 KW and Below


Residential air handlers

Low Voltage Wiring 15 KW and Above


Residential air handlers

Low Voltage Wiring for Heat Pumps

10 KW and Below


Residential air handlers

Low Voltage Wiring for Heat Pumps

15 KW and Above


Orifice change

Orifice Change

  • The restrictor (orifice) included in this unit should match the comparable capacity of the outdoor unit.

  • The restrictor (orifice) should be replaced before any tubing connections are made.

  • The capacity of the outdoor unit should never exceed the capacity of the indoor unit.


Residential air handlers

ORIFICE CHANGE OUTS


Thank you

any questions?

Thank you!