1 / 26

The HERMES Polarized H&D Gas Target: 10 Years of Operation

The HERMES Polarized H&D Gas Target: 10 Years of Operation. Erhard Steffens University of Erlangen-Nürnberg and HERMES Collaboration (DESY-Hamburg). Introduction and history Polarized gas targets in a high energy storage ring Overview of HERMES H&D target

reese
Download Presentation

The HERMES Polarized H&D Gas Target: 10 Years of Operation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The HERMES Polarized H&D Gas Target: 10 Years of Operation Erhard Steffens University of Erlangen-Nürnberg and HERMES Collaboration (DESY-Hamburg) • Introduction and history • Polarized gas targets in a high energy storage ring • Overview of HERMES H&D target • Summary of runs 1996 to 2005 (H║, D║ H┴) • Conclusions E. Steffens – Spin 2006

  2. The Clue to High Density: Storage Cells • Storage Cell proposed by W. Haeberli • Proc. Karlsruhe 1965, p. 64 • Proc. Workshop IUCF 1984, AIP Conf. Proc.#128, p.251 • Ballistic flowfrom AtomicBeam Source (H, D) • Flow driven by pressure gradient Laser Driven Sources (H, D, 3He) Polarized atoms from source Target areal density given by t = L ro with ro = It / Ctot and Ctot = S Ci Note:Conductance of tube proportional to d3/L T-shaped storage cell Density gain compared to Jet of same intensity can be up to several hundred! E. Steffens – Spin 2006

  3. 1st Test of a Storage Cell in a 2 GeV Electron Storage Ring: VEPP-3 at BINP • Storage cell surface is coated to inhibit recombination and depolarization • Coatings like Teflon or Drifilm are sensitive to Synchrotron Radiation (= hard X-rays) • First test of storage cell (uncooled, Drifilm coating) performed by BINP-ANL collaboration in 1988: R.A. Gilman et al, PRL 65 (1990) 1733 • Results show that the coating is stable on the time scale of ½ year! Aymmetry for electro-disintegration of the deuteron as function of running time for a polarized deuterium storage cell target in the VEPP-3 storage ring at BINP Found later: In the cooled HERMES storage cell (T = 100 K) a water surface is formed with superior quality E. Steffens – Spin 2006

  4. Expectations Paris 1990 Talk on: ‚Experiments with Dense Polarized Internal Targets‘ I E. Steffens – Spin 2006

  5. Expectations Paris 1990 II E. Steffens – Spin 2006

  6. Past History: FILTEX • Goal: spin filtering of antiprotons (proposal 1985) • Tool: dense polarized H target in p_bar storage ring LEAR (CERN) • Test experiment with protons in the Heidelberg test storage ring TSR 1992 E. Steffens – Spin 2006

  7. Past History: FILTEX E. Steffens – Spin 2006

  8. Past History: FILTEX W. Korsch, F. Rathmann, K. Zapfe, P. Schiemenz † 1014/cm2 demon- strated! High polari- zation in weak field! • View into the FILTEX target chamber • rear: last 6-pole (SmCo) • center: T-shaped storage cell • right: cryopump with hole for beam E. Steffens – Spin 2006

  9. HERMES experiment proposed for the HERA 30 GeV polarized electron ring - Letter of Intent 1988 - Proposal 1990 - Technical Design Report 1993 - First Operation in April 1995 (with pol. 3He target) The HERMES Experiment Physics: see talk by E. Aschenauer (Wedn.) • Requirements on the target: • - Areal density t = 1014/cm2 in two substates OK • - Sampling polarimeter with DP/P = 3% ? • - Coating stable wrt synchrotron radiation (OK?) • - Suppression of Wake Fields in the target Simulations OK • - Suppression of beam-induced (rf) depolarization „ „ „ Several open questions left... E. Steffens – Spin 2006

  10. HERMES Target- Overview Target chamber E. Steffens – Spin 2006

  11. HERMES Target 1996 H-Target installed in early 1996 Erlangen Liverpool Madison Marburg Munich Yerevan F. Stock B. Braun G. Graw G. Court T. Wise et al E. Steffens – Spin 2006

  12. Collimated cold atomic beams produced by disso-ciator with cold nozzle (100K) and differential pumping system (SSi ~104 l/s) Spin-dependent focussing of H and D atomic beams by 6-pole magnets: mJ= +1/2 Nuclear polarization Pz,Pzzproduced by means of rf transitions with ~100% effi-cieny; rapid switching enabled Atomic Beam Source (ABS) Heidelberg-Marburg-Munich-Madison Bc = 50.7 mT E. Steffens – Spin 2006

  13. Design of Target Chamber G. Court – Liverpool T. Wise – Madison H&D Collimator C2 e± Target Cell 400mm Wake Field Suppr. SC Coils E. Steffens – Spin 2006

  14. Cell optimized for operation in an electron storage ring Conducting surface with smooth variation of cross section excitation of wake fields! System of W collimators for protection against beam and SR Cooled via cooling rails by cold He gas to 60-100K 75mm Al walls with Drifilm coating - Radiation damage visible! But: Very effective wall coating due to ice layer maintained by small fraction of water in the atomic beam ! Storage Cell Design Liverpool-Madison-Ferrara E. Steffens – Spin 2006

  15. Diagnostics B. Braun, Ch. Baumgarten, P. Lenisa, et al • Target gas analyzer (TGA) • -measures degree of dissociation a to 1% in few minutes • - molecules (with polarization fraction b) dilute nuclear polarization • - enters the final values of target polarization Sketch of the TGA: E. Steffens – Spin 2006

  16. Diagnostics • Target gas analyzer (TGA) • -measures degree of dissociation a to 1% in few minutes • - molecules (with polarization fraction b) dilute nuclear polarization • - enters the final values of target polarization Temperature scan on new cell (hydrogen 1997) E. Steffens – Spin 2006

  17. Diagnostics • Target gas analyzer (TGA) • -measures degree of dissociation a to 1% in few minutes Temperature scan on used cell (deuterium 2000) after formation of water layer no T-dependence visible no recombination in the cell! E. Steffens – Spin 2006

  18. Diagnostics • Sampling polarimeter (BRP) • -measures substate population ni of sample beam to Dn/n = 1% in few minutes • - BRP polarizations Pe (electrons) and Pz , Pzz (nuclei) calculated • - Sampling corrections applied to calculate PTarget seen by the beam! Erlangen-Heidelberg-Munich-Ferrara-Yerevan D. Braun, Ch. Baumgarten, G. Graw, D. Reggiani, P. Lenisa et al Detector Sample Beam Schematic view of Sampling Polarimeter E. Steffens – Spin 2006

  19. Diagnostics • Sampling polarimeter (BRP) • -measures substate population ni of sample beam to Dn/n = 1% in few minutes Hydrogen hfs-population as function of holding field Detector Sample Beam B. Braun Thesis, Munich 1995 E. Steffens – Spin 2006

  20. Diagnostics • Sampling polarimeter (BRP) • -measures substate population ni of sample beam to Dn/n = 1% in few minutes • - BRP polarizations Pe (electrons) and Pz , Pzz (nuclei) calculated BRP polarization for the deuterium run 2000 top: vector pol. Pz bottom: tensor pol. Pzz E. Steffens – Spin 2006

  21. Beam-induced Depolarization • HERA-e: • Bunch frequency nBunch = 10.4 MHz • Bunch length st = 38 ps Harmonics nn = n·nB up to very high harmonics! (nmax≈ 103 corr. to 10 GHz) h·nn Resonance condition: DE(Bn) = h·nn → resonant guide fields Bn exist! Bn E. Steffens – Spin 2006

  22. Beam-induced Depolarization • blue:p resonances (DmF = ± 1) • red:s resonances (DmF = 0) narrow-spaced! • Transverse target only s24 p34 E. Steffens – Spin 2006

  23. Beam-induced Depolarization Ferrara-Erlangen-Peking BRP used to detect the resonances induced by harmonics of the bunch field! Shown: the widely spaced p resonances • HERA-e: • Bunch frequency nBunch = 10.4 MHz • Bunch length st = 38 ps Harmonics nn = n·nB up to very high harmonics! (nmax≈ 103 corr. to 10 GHz) Resonance condition: DE(Bn) = h·nn → resonant guide field Bn exists! p 3-4 p 1-2 B-scan of p-resonances E. Steffens – Spin 2006

  24. Beam-induced Depolarization Ferrara-Erlangen-Peking BRP used to detect the resonances induced by harmonics of the bunch field! Shown: the narrow s resonances • HERA-e: • Bunch frequency nBunch = 10.4 MHz • Bunch length st = 38 ps Harmonics nn = n·nB up to very high harmonics! (nmax≈ 103 corr. to 10 GHz) Correction coil For optimum setting of correction current: Small change of BRP detector current by the bunch field → Beam-induced depolarization is low! No beam B-scan of s-resonances E. Steffens – Spin 2006

  25. Target Performance recombination spin exchange wall depol. beam induced calculated target polarization → target areal density → Figure Of Merrit E. Steffens – Spin 2006

  26. Conclusions • Polarized H&D target successfully operated over 10 years in a HE electron storage ring more or less continuesly • Several problems solved during commissioning phase(s) thanks to many enthousiastic collaborators – impossible to name them all! • Nature was kind to us (no show-stopper)  • Technology ready to be used for other projects! www.fz-juelich.de/ikp/pax E. Steffens – Spin 2006

More Related