Reducing Energy Consumption of Disk Storage Using Power-Aware Cache Management - PowerPoint PPT Presentation


  • 74 Views
  • Uploaded on

Reducing Energy Consumption of Disk Storage Using Power-Aware Cache Management. Q. Zhu, F. David, C. Devaraj, Z. Li, Y. Zhou, P. Cao* University of Illinois at Urbana Champaign & *Cisco Systems Inc. HPCA ‘04 Presented by: Justin Kliger & Scott Schneider. Motivation.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Reducing Energy Consumption of Disk Storage Using Power-Aware Cache Management' - ray


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Reducing energy consumption of disk storage using power aware cache management

Reducing Energy Consumption of Disk Storage Using Power-Aware Cache Management

Q. Zhu, F. David, C. Devaraj, Z. Li, Y. Zhou, P. Cao*

University of Illinois at Urbana Champaign &

*Cisco Systems Inc.

HPCA ‘04

Presented by: Justin Kliger & Scott Schneider


Motivation
Motivation Power-Aware Cache Management

  • Reduce Energy Consumption

    • Targeting large data center such as EMC Symmetrix (right)

      • 10-50 TBytes

      • 128 GB of non-volatile memory cache


Motivation1
Motivation Power-Aware Cache Management

  • Dealing with large data storage and large caches separated from application servers


Motivation2
Motivation Power-Aware Cache Management

  • Consume huge amounts of power:

    • Currently consuming 150-200 W/ft2

    • Expect an increase up to 25% annually

    • Storage devices already account for 27% of power consumption at data center

  • Significance of reducing energy consumption:

    • Can limit costs to these data centers

    • Keeps energy costs from becoming prohibitive and preventing data center expansion

    • Positive environmental impacts


Motivation3
Motivation Power-Aware Cache Management

  • Focusing on cache replacement algorithm, conserve energy by changing the average idle time of disks

  • Create Power-Aware algorithm

    • Designate priority disks to allow some disks to greatly increase idle time

    • Selectively keep blocks in cache from priority disks to decrease power usage


Outline
Outline Power-Aware Cache Management

  • Background for Disk Power Model

  • Off-line analysis

  • Online algorithm

  • Evaluation & Results

  • Write Policies

  • Conclusion, Impact & Further Research


Disk power model
Disk Power Model Power-Aware Cache Management

  • Conventional disks have three states

    • Active and Idle consume full power

    • Standby consumes less power, but requires a spin up to satisfy a request

  • Gurumuthi et al. proposed multi-speed disks

    • Lower rotational speeds consume less energy

    • Transition from lower speed to next higher speed is smaller than switching from standby to active


Disk power model1
Disk Power Model Power-Aware Cache Management

  • Their disk model uses these proposed multi-speed disks

    • Multi-speed disks can be configured to service requests at all speeds or only the highest speed

    • Only servicing requests at highest speed makes the disks essentially multi-state disks, as opposed to two-state disks

  • Their model uses 4 intermediate lower power modes


Disk power management
Disk Power Management Power-Aware Cache Management

  • Oracle disk power management (DPM)

    • Term for when entire sequence is known ahead of time, perfect power management is possible

    • Provides upper bound on energy saved

  • Upon request completion

    • Oracle DPM examines interval length t between requests

    • If t is greater than break-even time, spin disk down immediately


Disk power management1

The minimum energy consumption is the curve that intersects with the consumption line for each state

Online algorithms uses these crossover points as thresholds

Disk Power Management


Dpm and cache replacement
DPM and Cache Replacement with the consumption line for each state

Disk

Disk

Disk

Disk

Disk

Disk

Disk


Dpm and cache replacement1
DPM and Cache Replacement with the consumption line for each state

DPM

DPM

DPM

DPM

DPM

Disk

Disk

Disk

Disk

Disk

Disk

Disk


Dpm and cache replacement2
DPM and Cache Replacement with the consumption line for each state

Cache Replacement Policy

DPM

DPM

DPM

DPM

DPM

Disk

Disk

Disk

Disk

Disk

Disk

Disk


Power aware off line algorithms
Power-Aware Off-line algorithms with the consumption line for each state

  • Optimal cache-hit algorithm (Belady’s) can be suboptimal for power-consumption

    [Figure 3: An example showing Belady’s algorithm is not energy-optimal]

6 misses; 24 time units at high energy consumption


Power-Aware Off-line algorithms with the consumption line for each state

  • Optimal cache-hit algorithm (Belady’s) can be suboptimal for power-consumption

    [Figure 3: An example showing Belady’s algorithm is not energy-optimal]

7 misses; 16 time units at high energy consumption


Power aware off line algorithms1
Power-Aware Off-line Algorithms with the consumption line for each state

  • Energy Optimal Algorithm

    • Developed polynomial-time algorithm with dynamic programming, but not applicable to aiding online algorithm, details not included

  • Off-line Power-Aware Greedy Algorithm

    (OPG)

    • More realistic, used as comparison in traces

    • Considers future deterministic misses


Power aware off line algorithms2
Power-Aware Off-line Algorithms with the consumption line for each state

OPG:

  • Evicts blocks with minimum energy penalty:

    • OL(Li) + OL(Fi) – OL(Li + Fi) = Practical DPM

    • LE(Li) + LE(Fi) – LE(Li + Fi) = Oracle DPM

  • Time complexity is O(n2)

  • Heuristic because only considers the current set of deterministic misses


Power aware online algorithm
Power-Aware Online Algorithm with the consumption line for each state

  • Insight gained from off-line analysis: avoid evicting blocks with large energy penalties

  • Small increases in idle time can have big energy gains


Online approach
Online Approach with the consumption line for each state

  • Online algorithm goals

    • Use the cache replacement policy to reshape each disk’s access pattern

    • Give priority to blocks from inactive disks to increase average idle time

    • Allow average interval time of some disks to decrease so that interval time of already idle disks can increase

  • Overall energy consumption is reduced


Other online factors
Other Online Factors with the consumption line for each state

  • Potential energy savings are also determined by

    • Percentage of capacity misses must be high in a workload; cold misses can’t be avoided

    • Distribution of accesses determine actual interval lengths; larger deviation from the mean has more opportunity for savings

  • An online algorithm needs to identify these properties for each disk to make good decisions


Tracking cold misses
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk


Tracking cold misses1
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk

  • Example, m = 13, k = 4

h1()

h2()

h3()

h4()

0

0

0

0

0

0

0

0

0

0

0

0

0


Tracking cold misses2
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk

  • Example, m = 13, k = 4

a

h1(a)

h2(a)

h3(a)

h4(a)

0

0

0

0

0

0

0

0

0

0

0

0

0


Tracking cold misses3
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk

  • Example, m = 13, k = 4

a

h1(a)

h2(a)

h3(a)

h4(a)

0

0

0

0

0

0

0

0

0

0

0

0

0


Tracking cold misses4
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk

  • Example, m = 13, k = 4

a

h1(a)

h2(a)

h3(a)

h4(a)

0

1

0

0

1

0

1

0

0

1

0

0

0


Tracking cold misses5
Tracking Cold Misses with the consumption line for each state

  • Use a Bloom Filter to track cold misses

    • allocate a vector v of m bits

    • k independent hash functions, h1, h2, ..., hk

  • Identifying a cold miss is always correct

  • False positives are possible for non-cold misses

    • For 1.6M blocks with v set to 2M and k = 7, false positives happen 0.82% of the time


Distribution estimate
Distribution Estimate with the consumption line for each state

  • Disk access distribution is estimated using an epoch-based histogram technique

  • We use an approximation method to estimate the cumulative distribution function of interval length of a disk, F(x) = P[X ≤ x]


Distribution estimate1
Distribution Estimate with the consumption line for each state

  • In each epoch

    • Track interval length between consecutive disk accesses

    • Each interval falls into a discrete range

    • The sum of each range and all ranges above it approximates the cumulative probability below that range


Power aware cache management
Power Aware Cache Management with the consumption line for each state

  • Dynamically track cold misses and cumulative distribution of interval lengths for each disk

  • Classify disks, each epoch, as

    • Priority disks have a “small” percentage of cold misses and large interval lengths with a “high” probability

    • Regular disks are the rest


Power aware cache management1
Power Aware Cache Management with the consumption line for each state

  • The basic idea: reshape the access pattern to keep priority disks idle

  • PA can be combined with other algorithms such as LIRS, ARC, MQ, etc.


Example pa lru
Example: PA-LRU with the consumption line for each state

  • PA-LRU employs two LRU stacks

    • LRU0 keeps regular disk blocks

    • LRU1 keeps priority disk blocks

  • Blocks are evicted from bottom of LRU0 first, then bottom of LRU1

  • Parameters

    • α is the cold misses threshold

    • p is the cumulative probability

    • β is the CDF threshold

    • epoch length


Overall design
Overall Design with the consumption line for each state

Cache Replacement Policy

DPM

DPM

DPM

DPM

DPM

Disk

Disk

Disk

Disk

Disk

Disk

Disk


Overall design1
Overall Design with the consumption line for each state

PA Classification Engine

Cache Replacement Algorithm

DPM

DPM

DPM

DPM

DPM

Disk

Disk

Disk

Disk

Disk

Disk

Disk


Evaluation
Evaluation with the consumption line for each state

  • Specifications of disk:

  • Additionally, 4 more low-speed power modes: 12000RPM, 9000RPM, 6000RPM, 3000RPM


Evaluation1
Evaluation with the consumption line for each state

  • Two System traces: OLTP & Cello96

  • Cache Size:

    • For OLTP = 128 MBytes

    • For Cello96 = 32 MBytes


Evaluation2
Evaluation with the consumption line for each state

  • Compared 4 algorithms:

    • Belady’s, OPG, LRU, PA-LRU

    • Also measured disk energy consumption with infinite cache size – provides lower bound

      (only cold misses access disk)

  • Practical DPM use thresholds identified earlier as competitive with Oracle

  • PA-LRU uses 4 parameters:

    • Epoch length = 15 minutes, α= 50%, p = 80%, β= 5 seconds


Results
Results with the consumption line for each state

  • PA-LRU can save 16% more energy than LRU on OLTP trace

  • However, PA-LRU only saves 2-3% more energy than LRU for Cello96 trace


Results1
Results with the consumption line for each state

How PA-LRU improves performance:

4

14

= PA-LRU


Write policies
Write Policies with the consumption line for each state

  • Four write policies

    • WB: Write-Back only writes dirty blocks upon eviction

    • WT: Write-Through writes dirty blocks immediately

    • WBEU: Write-Back with Eager Updates writes a block immediately if that disk is active; otherwise it waits

    • WTDU: Write-Through with Deferred Update writes dirty blocks to a log if the target disk is in a low power mode


Write policies evaluation
Write Policies Evaluation with the consumption line for each state

  • Synthetic traces that varied write/read ratios and the interarrival time

  • WB vs. WT Write-Back consistently better up to 20%

  • WBEU vs. WT WBEU consistently better up to 65%

  • WTDU vs. WT WTDU consistently better up to 55%


Conclusion
Conclusion with the consumption line for each state

  • Effective analysis for off-line algorithm (OPG)

  • Designed and evaluated Power-Aware online algorithm (PA-LRU), which can use 16% less energy than LRU

  • Considered write policy effects on energy savings


Impact of work
Impact of work with the consumption line for each state

  • Theoretical off-line analysis of power-aware caching policies

  • Identification of requirements for an online power-aware caching algorithm

  • Published in 2004; 3 self citations plus Pinheiro, Bianchini ICS 04 and Papathanasiou, Scott USENIX 04


Further research
Further Research with the consumption line for each state

  • Reduce # of parameters (PB-LRU)

  • Online algorithm applied to single disks

  • Prefetching

  • Consider storage cache energy consumption

  • Evaluate in real storage system context