An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Low background facilities at LSM Pia Loaiza ILIAS meeting, Modane January 12th 2005

  2. Ge detectors at LSM As S ~ /BDF, Gentiane and IRIS have roughly the same sensitivity at 583 keV and 1461 keV. At present, the sensitivity are, typically, 1 mBq/kg for “reasonables” mass and measurement time.

  3. On-going projects at the LSM • Improvement of a low background Ge detector (IRIS, 400 cc). • Prospective construction materials are being measured. Monte Carlo simulations are performed to get the distinct contribution to the background from the assembly • materials and to determine the maximum acceptable radioactivities in order to get an improvement of a factor 5 in the detector background. • We’ve found a high Th activity (0.13 Bq/kg @ 238 keV) in one of the insulators near the crystal, which need to be replaced by other material.

  4. On-going projects at the LSM • New planar Ge detector : our needs regarding low-energy gamma detection • require a new planar Ge (diam = 80 mm, d=35 mm), with a resolution of • 0.7 keV at 50-60 keV. Performances of detectors in the market are being • evaluated. • Cryogenerators : We plan to equip one Ge detector with a system • of cryogenerators. Evaluation of possibilities of installation on one • of our detectors is under way. • Constructionof a Radon precision • measuring facility, with a sensitivity of • ~ mBq/m3 (Vol. 70 l)

  5. Radon trapping facility Installation September 2004

  6. Radon trapping facility Time during which radon is trapped in the « filter » : Tr = K(T) M / Q K(T) : dynamic adsorption coeff. M : charcoal mass Q : Air rate 2 charcoal towers : T1 = -53 C, T2 = -45 C M = 2 x 450 kg Radon purification by adsorption in charcoal Vol. clean air : 150 m3/h Activity 222Rn = 15 mBq/m3