1 / 8

March 12th-13th, 2002 International Systems Fire Protection Working Group Seattle, Washington

An Overview of FAA Fuel Inerting Research. March 12th-13th, 2002 International Systems Fire Protection Working Group Seattle, Washington. Vertical Mixing / Temperature Effects.

preston
Download Presentation

March 12th-13th, 2002 International Systems Fire Protection Working Group Seattle, Washington

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. An Overview of FAA Fuel Inerting Research March 12th-13th, 2002International Systems Fire Protection Working GroupSeattle, Washington AAR-422 Fire Safety R&D

  2. Vertical Mixing / Temperature Effects • Quiescent Full-Scale Testing has Indicated that Inerting of the B-747 SP in the Optimal Deposit Method Developed with the Plywood Model can be Problematic • Inerting Efficiency Different from Test to Test • Measured Strong “Vertical Effects” in one Full Length Bay • Bottom of Bay Lags Behind Top of Bay on Most Tests • Complicated by the Fact that Sample System only Samples from Top • Observed Stratification of Inert Gas at Least Once with No Temperature Variation Between the Inert Gas and the Ullage • Developed Deposit Gas Heat Exchanger to Study Temperature Effects • Developed Inerting Efficiency Coefficient to Compare Tests • Back Calculate VTEs between 1.2 and 2.0 to reach 8% [O2] with 95% AAR-422 Fire Safety R&D

  3. Full-Scale B-747 SP Inerting Data AAR-422 Fire Safety R&D

  4. Inerting Efficiency • Due to Sample Lag Don’t have a Good Picture of Inerting in the Tank During Test • Sample Biased Due to Location of Sample Ports • Know Beginning Point (20.9) and End Point After Run ACMs • Want to Approximate the Progression of Tank Oxygen Concentration During the Testing • Use Generic Inerting Equation to Develop Efficiency Factor K • Solve for K and Redimensionalize to Get a Curve for Each Test Result • Did Several Tests with Different Temperature NEA AAR-422 Fire Safety R&D

  5. Full-Scale B-747 SP Inerting Data AAR-422 Fire Safety R&D

  6. Ancillary Equipment Development • Cross-Flow Reduction Device • Wrote and Distributed RFQ to Qualified Contractors for Developing a Cross-Flow Reduction Device for a B-747 SP • Three Phase Development to Optimize One of Three Proposed Concepts, then Design and Fabricate a Part for Kit Installation • OBGI Deposit System • FAA Developing a Method for Distributing the OBGI System Gas by Using Scale Plywood Tank Testing • RFQ for Development and Prototype in mid March AAR-422 Fire Safety R&D

  7. Flammability Survey of B-747 SP • Measured Heating and Flammability Parameters in CWT of Full-Scale Test Article During “Typical” Ground Operation with Low Fuel • Inert Tank Before Each “Ground Sit” (During Test) • Target Different Temperature Days (Relatively Constant Ambient Temperature) with Mild Weather • Run ACMs for 3 Hours to Make Cabin Comfortable • Thermocouples in Pack Bay, Ullage, and Fuel (and Sump) as well as On Walls, Floor, and Ceiling • All Data Obtained on Cool and Warm Days • Need Heat of Summer and Cold of Winter Data AAR-422 Fire Safety R&D

  8. B-747 SP Flammability Data AAR-422 Fire Safety R&D

More Related