WELL COME TO TRAINING PROGRAME
This presentation is the property of its rightful owner.
Sponsored Links
1 / 38

APPLICATION & OPERATION OF TOTAL STATION OVERSEAS MARKETING CORPORATION (PVT),LTD PowerPoint PPT Presentation


  • 133 Views
  • Uploaded on
  • Presentation posted in: General

WELL COME TO TRAINING PROGRAME On. APPLICATION & OPERATION OF TOTAL STATION OVERSEAS MARKETING CORPORATION (PVT),LTD Association with Local Government Engineering Department ( LGED). Training Summery. What is Total Station? Total Station Overview Basic Concept Series Features

Download Presentation

APPLICATION & OPERATION OF TOTAL STATION OVERSEAS MARKETING CORPORATION (PVT),LTD

An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -

Presentation Transcript


Application operation of total station overseas marketing corporation pvt ltd

WELL COME TO TRAINING PROGRAME

On

APPLICATION & OPERATION OF TOTAL STATION

OVERSEAS MARKETING CORPORATION (PVT),LTD

Association with

Local Government Engineering Department ( LGED)


Application operation of total station overseas marketing corporation pvt ltd

Training Summery

  • What is Total Station?

  • Total Station Overview

    • Basic Concept

    • Series Features

  • Application Software

  • Operation/Application


Application operation of total station overseas marketing corporation pvt ltd

INTRODUCTION - TOTAL STATION

Total Station is an electronic device, which can determine the coordinate of a target point in a digital form.

It transmits beam of infrared light towards the target (reflector) & receive the reflected beam from the prism & calculate the distance, bearing & 3D coordinate of that target point with respect to the reference point.


Application operation of total station overseas marketing corporation pvt ltd

Traditional Survey Equipment & Total Station

  • Distance & Level

  • Bearing / Angle

  • Co-Ordinate (GPS)


Application operation of total station overseas marketing corporation pvt ltd

SECUANTIOL STAGE OF TOTAL STATION


Application operation of total station overseas marketing corporation pvt ltd

Main Technical Data

“Ultimate Standard”

  • Highest Protection against Dust and Water: IP66

  • Consistence speedMeas. Time: 0.9sec

  • World-proven, Time-tested Angle Reading System: Absolute Encoder

  • Quick Operation in All Conditions: Easy-to-use control panel

  • Security: Password function

  • Flexible Data Management:

    SD/SDHC&USB slot

    Bluetooth class2 (option)

  • Built-in Laser Plummet (option)


Application operation of total station overseas marketing corporation pvt ltd

Parts of Total Station


Application operation of total station overseas marketing corporation pvt ltd

Parts of Total Station


Application operation of total station overseas marketing corporation pvt ltd

Input Parts of Total Station


Application operation of total station overseas marketing corporation pvt ltd

Soft Key Operation

Select <S-O data>

[ESC] key

[ S-O] key

[OK] key

[OK] key


Application operation of total station overseas marketing corporation pvt ltd

Password Protection Function

  • Security purposes

  • 3 to 8 alphanumeric characters


Application operation of total station overseas marketing corporation pvt ltd

Application

  • Distance and Angle Measurement

  • Angle Measurement

  • Area Calculation

  • Remote Elevation Measurement (REM)

  • 3-D Coordinates Measurement

  • Resection

  • Set-out

  • Point Projection

  • Traverse Adjustment


Application operation of total station overseas marketing corporation pvt ltd

Surveying Work Flow

  • Tripod Setup On a Known Point

  • Instrument Setup on Tripod

  • Centering & Leveling the Instrument

  • Configuration (one time)

  • Job open (If required)

  • Backside Point Setup (Prism)

  • Start Measure

  • Data Transfer to PC


Application operation of total station overseas marketing corporation pvt ltd

  • Instrument Set up on The Station

  • Set the Tripod on the Known Point

  • Put the Instrument on Tripod &

  • Confirm Centering using by

  • Optical plummet

  • Confirm leveling by Horizontal &

  • Base Circular level

  • Set the prism on the Known Point

  • Power on the TS


Application operation of total station overseas marketing corporation pvt ltd

Instrument Configure


Application operation of total station overseas marketing corporation pvt ltd

JOB Open

Data Transfer

MEAS/---MEM/ CONFG (F3)

MEAS/---MEM/ CONFG (F3)

Job

(Enter)

Comms output

(Enter)

Selection

(enter)

Select

(enter)

Job Name Edit

(enter)

PC Work

Coms setup)

Enter

Unit

OK

Surveying Work Flow


Application operation of total station overseas marketing corporation pvt ltd

Measure (P1)

MEAS/---MEM/ CONFG (F1)

Distance

(F1)

SHV(Slope, Horizontal, Vertical Distance)

(F2)

O SET(Horizontal angle)

(F3)

AIM

(F4)

FUNC for Page Change

Surveying Work Flow


Application operation of total station overseas marketing corporation pvt ltd

Surveying Work Flow


Application operation of total station overseas marketing corporation pvt ltd

Target/ Prism Setting


Application operation of total station overseas marketing corporation pvt ltd

Application

Angle Measurement

The included angle between two points can be measured using ‘0SET’ function.

  • Sight to the first target

  • Press F3 for ‘0SET’ and it will flash.

  • Press F3 again while ‘0SET’ is flashing and horizontal angle display will set to 0º 00’ 00”.

  • Then sight to the second target and the horizontal angle display is the included angle between 2 points.


Application operation of total station overseas marketing corporation pvt ltd

Application

Distance and Angle Measurement

Distance and Angle can be measured at the same time using F1 (DIST).


Application operation of total station overseas marketing corporation pvt ltd

Area Calculation


Application operation of total station overseas marketing corporation pvt ltd

Remote Elevation Measurement (REM)


Application operation of total station overseas marketing corporation pvt ltd

Application

Remote Elevation Measurement


Application operation of total station overseas marketing corporation pvt ltd

3-D Coordinates Measurement


Application operation of total station overseas marketing corporation pvt ltd

Application

Coordinate Measurement


Application operation of total station overseas marketing corporation pvt ltd

Resection


Application operation of total station overseas marketing corporation pvt ltd

Application

Resection Measurement


Application operation of total station overseas marketing corporation pvt ltd

Set-out


Application operation of total station overseas marketing corporation pvt ltd

Application

Setting-out Measurement


Application operation of total station overseas marketing corporation pvt ltd

Application

Setting-out Line


Application operation of total station overseas marketing corporation pvt ltd

Point Projection


Application operation of total station overseas marketing corporation pvt ltd

Application

Point Projection


Application operation of total station overseas marketing corporation pvt ltd

Application

Traverse Adjustment


Application operation of total station overseas marketing corporation pvt ltd

Using External Memory Media

Slide the catch on the external interface hatch cover down to open.

Insert the memory device in the respective slot.

The contact part of SD card should be facing the instrument.

To remove SD card from slot, push further in first. Then release to eject.


Application operation of total station overseas marketing corporation pvt ltd

Using External Memory Media

Selecting Media Type

  • Power on the instrument.

  • By default, the instrument will be in measurement page.

  • Press ‘ESC’ to get into status page.

  • Press ‘MEDIA’ to get into media mode.

  • Select ‘Media selection’

  • Select desire media type from ‘SD’ or ‘USB’ using left/right arrow key

  • Then press ‘OK’


Application operation of total station overseas marketing corporation pvt ltd

Using External Memory Media

Storing Job Data

  • Select ‘Save data’ in ‘Media’

  • Select the job to be recorded and press ‘Enter’. ‘Out’ will be displayed to the right of the selected job

  • Then press ‘F4’ for ‘OK’

  • Enter name for the job file (by default, job file name in the instrument will be assigned)

  • Then press ‘F4’ for ‘OK’ and the job file will be saved in the selected medium with entered file name.


Application operation of total station overseas marketing corporation pvt ltd