IENG 471 - Lecture 09

IENG 471 - Lecture 09. Personnel Planning - Parking. Assignments. Current Assignment: HW 5: Team Assignment, 2 people per team, turn in 1 HW set per team. b.) assume separate restrooms, industrial facility (non-foundry) and assume they want minimal space increase Next Assignment:

peggyh
Download Presentation

IENG 471 - Lecture 09

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IENG 471 - Lecture 09 Personnel Planning - Parking IENG 471 Facilities Planning

  2. Assignments • Current Assignment: • HW 5: Team Assignment, 2 people per team, turn in 1 HW set per team. • b.) assume separate restrooms, industrial facility (non-foundry) and assume they want minimal space increase • Next Assignment: • Prep for Exam II Parking Lot Problem, 2 people per team – see last slide for today • Measuring tools are in the MIL Lab (IER 310) on the South blue pegboard • Return the tools ASAP • Layout the parking lot according to the handout heuristic • Show your work (for your OWN benefit) • Put this on EP paper for your use on the second exam and keep it in your engineering notebook. • Exam dimensions and design constraints may be similar, but different. • Good idea to clearly document what you did, so you can adapt your model for the exam quickly. IENG 471 Facilities Planning

  3. Parking Lot Design • Goals vary depending on Facility purpose • Examples: • Airport • Regional Hospital • Home Improvement Store • Supermarket (no drive up) • Manufacturing Plant • College Campus (commuter school) • College Campus (pedestrian mall) • Military Base IENG 471 Facilities Planning

  4. Parking Lot Design • General Rules of Thumb: • Local zoning regulations tend to be more restrictive, and supersede most guidelines (they may also be negotiated) • OSHA / other standards may (indirectly) impact lot design • 500 feet is usually the maximum walking distance for regular patron access to the facility • 2% to 5% of capacity are Handicapped accessible spaces • 33% of spaces are allocated to compact cars • Increased area for parking decreases time for parking & de-parking (increases parking spot turns) • Angular configurations increase parking spot turns • Perpendicular parking often increases lot space utilization • Required aisle space increases with the parking angle • Vehicle sizes change over time IENG 471 Facilities Planning

  5. Parking Lot Design • Steps of Lot Design Heuristic: • Determine the number of vehicles to be parked • Determine the space required for each vehicle type • Determine the available space for parking • Generate alternative parking layouts for alternative parking patterns (lots may have alternative uses) • Select the best layout to maximize space utilization and regular patron convenience IENG 471 Facilities Planning

  6. Using the Parking Design Tables • Recommendations for Stall Widths • (Table 4.1 from Parking Lot Design Handout link on Materials Page) • Small car use: 7.5 to 8 feet • All-day parker: 8 to 8.5 feet • Standard car: 8.5 to 9 feet • Luxury/elderly: 9 to 10 feet • Supermarket: 10 to 11 feet • (also campers) • Handicapped: 11.8 to 12.2 feet IENG 471 Facilities Planning

  7. SD PW SW θ Using the Parking Design Tables • Parking Module Widths • (See top of Parking Lot Design handout from Materials Page) • Three Module Groups(relates stall width, module width, parking angle) • G1: Small Cars • G2: Standard Cars • G3: Large Cars • Four Module Types(gives width of module, including aisle) • W1: Single Loaded, Wall-to-Wall • W2: Double Loaded, Wall-to-Wall • W3: Double Loaded, Wall-to-Centerline • W4: Double Loaded, Centerline-to-Centerline • Parking Width (PW) is based on Parking Angle (θ) and Stall Width (SW): • Used to find the required lot depth IENG 471 Facilities Planning

  8. Maximized Utilization Heuristic Steps • Align Module Width to Lot Width • Layout using largest parking angle possible, preferring W4 modules to maximize space utilized per module • Layout remaining space with largest W module that can be accommodated, and then use largest parking angle possible • Reduce space in least efficient module to accommodate handicap or special case allocations, if allowable • Reduce spaces available at aisle ends for required cross-aisles and lot entrances / exits • Use Parking Width and remaining module lengths to compute the total number of vehicles accommodated • Align Module Width to other lot dimensions and repeat (best orientation might be neither perpendicular nor parallel) • Select the “best” of the layout options IENG 471 Facilities Planning

  9. Questions & Issues • Exam II Parking Lot Design Problem(prepare ahead for exam!): • Measure the IER parking lot AND the gravel area to the East for: • Location of utilities, side walks, building entrances & walls – considering them to be Monuments • Monuments are things that cannot be removed or relocated – like pillars • Dimensions to the nearest foot (rounding down) • Assume curb cuts, sign posts & foliage can be moved • Assume the width of the level part of the curb cut is the same as the width of a cross aisle (if any cross aisles are needed) • Using the Parking Lot Design handout, design the most efficient lot possible if the strategy for the lot is to allow quick turnover, and: • 90o parking must use the stall width midpoints, others can use smallest stall widths • 2% of the stalls are handicapped accessible (use largest stall width) • 10% of the stalls are for compact vehicles • 10% of the stalls are for large vehicles • Bumpers can overhang the sidewalks to the South and East, but not the West • Bumpers cannot encroach on the alley, or the garbage truck will hit them! IENG 471 Facilities Planning